Emission factor from Energimyndigheten

Bio-jet fuel - Component group

Sweden · Well-to-use · 2025 onwards

Each kilowatt-hour of this fuel from 2025 counts as 0.0439 kg CO₂e.

Value per kWh, net calorific value

0.0439kgCO₂e/kWh

Net calorific value · Biogenic CO₂ and land use excluded · GWP100 · AR4

FossilBio CH₄Land useBio CO₂GHG Protocol and IPCC inventories
2025–
Default: the latest year+79.3% on 2024
Region
Sweden SE
Boundary
Well-to-use
Data quality
MediumRated by us, not by the source
Licence
Open · Energimyndigheten terms

Where 0.0439 comes from

Published as one number

Energimyndigheten prints this factor as a single figure, with no parts to add up and no split by gas.

Reporting this kilowatt-hour under the GHG Protocol

Scope 1 + 3.3 Energy upstream 0.0439

This one figure covers both together; no split between them is given.

You burn the fuel, so its combustion is your Scope 1.

Supplying the fuel is Scope 3, category 3 for whoever burns it.

CiteAPI

The factor, standardised

Every factor on open-climate.ai answers the same questions in the same words, whatever the publisher. Open any ⓘ for the definition.

Fuels › Biofuels · Sweden · per kWh · Average

Well-to-use · Excl. biogenic CO₂ · AR4

Boundary
Well-to-use
Fuel supply and fuel combustion
GWP method
IPCC AR4, 100-year horizon
Not on the record; inferred by open-climate.ai
CO₂e basis
Excl. biogenic CO₂FossilBio CH₄Land useBio CO₂GHG Protocol and IPCC inventories
Not split by gas; CO₂e only

Medium quality · Open licence · 2021 to now

All values

5 values, one per year back to 2021. Every one is biogenic CO₂ and land use excluded, AR4 GWP100, so the years compare directly. Tap a bar.

2025 onwards0.0439Default value

kgCO₂e per kWh, by year. Pick a year to read it.

What this number covers

The path of one kilowatt-hour of this fuel, from the crops or residues it is made from to your engine or boiler.

  1. Fuel supply

    1. Feedstock

      Growing the crops or collecting the residues

    2. Processing

      Pressing, fermenting or refining it into fuel

    3. Transport

      Moving it to the tank you fill up from

  2. Your meter

    1 kWh used. The factor is per kWh measured here.

  3. Burning it

    In your engine or boiler: mostly CO₂ the plants took up as they grew, with a little CH₄ and N₂O

= 0.0439 per kWh

Outside this boundary

  • Making the engine that burns it
  • Building the pipelines and depots

Energimyndigheten counts the fuel, not the things built to extract, move and burn it.

From Energimyndigheten's record to a comparable factor

Energimyndigheten publishes this factor as one record. Here is each field as printed and what open-climate.ai made of it.

About this factor

Energimyndigheten gives no description for this factor. Filed under Komponentgrupp.

Source and licence

Publisher
Statens energimyndighet
Published
2 June 2026
Open the record at Energimyndigheten

The values and their metadata are served in full and may be reused with credit to the publisher.

Om du bearbetar statistiken ska du inte ange Energimyndigheten som källa. Men ange gärna att det är bearbetad statistik från Energimyndighetens webbplats.
Credit it with this lineKälla: Energimyndigheten
A plain reading of the licence, not legal advice. The licence text prevails.

Cite this factor

Källa: Energimyndigheten. Normalised by open-climate.ai, https://open-climate.ai/factors/libraries/energimyndigheten/ (CC BY 4.0). https://open-climate.ai/factors/ef-energimyndighete-biojet_komponentgrupp-se-kwh-well_to_use-cd1d4f3b/?v=efv1-311e4b07e4bddba16263d86afa8217b6

Something looks wrong?

Tell us which value and why. We check it against the source and answer within a week.

Page data as of .