Emission factor from Norsk Fjernvarme
Bio-oil (with sustainability criteria)
Norway · Well-to-use · Any year
Each kilowatt-hour of this fuel counts as 0.004 kg CO₂e, including 0.004 for producing it and bringing it to you.
Value per kWh, net calorific value
0.004kgCO₂e/kWh
Net calorific value · Biogenic CO₂ and land use excluded · GWP100 · GWP vintage not stated
FossilBio CH₄Land useBio CO₂GHG Protocol and IPCC inventoriesOne value, for any year
Norsk Fjernvarme sets no date window, so there is no year to pick.
Reference year 2020
- Region
- Norway NO
- Boundary
- Well-to-use
- Data quality
- LowRated by us, not by the source
- Licence
- Open · Norsk Fjernvarme terms
Where 0.004 comes from
- Fuel combustionThis part is not on open-climate.ai, so there is no page to open.Scope 1Not published here
- 3.3 Energy upstream0.004100%
Σ 0.004: the published part alone already equals Norsk Fjernvarme's total.
Reporting this kilowatt-hour under the GHG Protocol
3.3 Energy upstream 0.004
Supplying the fuel is Scope 3, category 3 for whoever burns it.
The part not published here cannot be given a scope.
The factor, standardised
Every factor on open-climate.ai answers the same questions in the same words, whatever the publisher. Open any ⓘ for the definition.
Fuels › Biofuels · Norway · per kWh · Average
Well-to-use · Excl. biogenic CO₂
- BoundaryWell-to-useOne unit of energy as consumed, priced from the well to the point of use: the well-to-tank chain plus the burn for a fuel; generation, its well-to-tank and the transmission and distribution losses for a delivered carrier (electricity, steam or hot water, chilled water). Learn more
- Well-to-use
- Fuel supply and fuel combustion
- GWP methodWhich IPCC assessment report's warming potentials convert each gas to CO₂e, and over how many years the warming is counted (GWP100: 100 years). Learn more
- Not stated by the publisher
- CO₂e basisWhich carbon the CO₂e counts. Fossil only leaves out biogenic methane, land-use change and biogenic CO₂; excl. biogenic CO₂ counts biogenic methane but not the other two; net total counts every pool, net of removals. The same activity on two bases is two different numbers. Learn more
- Excl. biogenic CO₂FossilBio CH₄Land useBio CO₂GHG Protocol and IPCC inventories
- Not split by gas; CO₂e only
Low quality · Open licence · Any year
What this number covers
The path of one kilowatt-hour of this fuel, from the crops or residues it is made from to your engine or boiler. Norsk Fjernvarme gives one figure for the first three steps together.
Fuel supply0.0043.3 Energy upstream
Feedstock
Growing the crops or collecting the residues
Processing
Pressing, fermenting or refining it into fuel
Transport
Moving it to your site
Your meter
1 kWh used. The factor is per kWh measured here.
Burning it
In your engine or boiler: mostly CO₂ the plants took up as they grew, with a little CH₄ and N₂O
Not published hereScope 1
= 0.004 per kWh
Outside this boundary
- Making the boiler that burns it
- Building the pipelines and the network
Norsk Fjernvarme counts the fuel, not the things built to extract, move and burn it.
Gases
Norsk Fjernvarme publishes this factor as CO₂e only, with no split by gas. The CO₂e leaves biogenic CO₂ and land-use carbon out; methane from biogenic sources is counted.
From Norsk Fjernvarme's record to a comparable factor
Norsk Fjernvarme publishes this factor as one record. Here is each field as printed and what open-climate.ai made of it.
The total and its parts
Each part has its own page. Use a part on its own when you report Scope 1 and Scope 3 separately; never add a part to the total.
Σ 0.004: the published part alone already equals Norsk Fjernvarme's total.
About this factor
Norsk Fjernvarme gives no description for this factor. Filed under Electricity, gas, steam and air conditioning supply.
Source and licence
- Publisher
- Norsk Fjernvarme
- Published
- 1 June 2020
The values and their metadata are served in full and may be reused with credit to the publisher.
Changes: values converted from g/kWh to kg/kWh; each column of Table 1 stored as its own factor. Norsk Fjernvarme does not endorse this use.
Cite this factor
Kilde: Norsk Energi for Norsk Fjernvarme, Klimaregnskap for fjernvarme 2020 (Dok ID 34223-00005-3.0), tabell 1. https://www.fjernkontrollen.no/uploaded/files/2020_06_01_klimaregnskap_for_fjernvarme_2020.pdf. Normalised by open-climate.ai, https://open-climate.ai/factors/libraries/norsk_fjernvarme/ (CC BY 4.0). https://open-climate.ai/factors/ef-norskfjernvarme-bioolje_med-no-kwh-well_to_use-60161d6a/?v=efv1-057cdbd299331e1f9f47e9d384bf16bf
Something looks wrong?