DFFE - Department of Forestry, Fisheries and the Environment (South Africa)

South Africa's national grid electricity factors and the country-specific fuel and livestock factors of its national greenhouse gas inventory, published by the Department of Forestry, Fisheries and the Environment (DFFE).

Government
  • Grid mix
  • Electricity
SpecialistRestricted licence
Factors
38
Values
51

One per year and method

Countries
1

1 region, sub-national included

Edition
gef-2024 + nir-1990-2024-draft

published 11 Sept 2026 · all versions

Last loaded
3 Nov 2026

Report a newer version

Overview

The Department of Forestry, Fisheries and the Environment (DFFE) is the South African government department responsible for climate change reporting. It publishes its emission factors in the Government Gazette, as PDFs, and we load two of them.

  • The Grid Emission Factors Report 2024 (Government Gazette No. 55353, GN 7891, 11 September 2026), the fourth edition of an annual report. It gives the emission factor of the national grid for the data years 2021 to 2024, written for companies reporting their Scope 2 emissions.
  • The draft National GHG Inventory Report for South Africa 1990-2024 (Government Gazette No. 54758, GN 7537, 29 May 2026), the tenth inventory, published for comment. We load only the factors South Africa measured itself, not the international defaults it reprints.

At a glance

Publisher
Department of Forestry, Fisheries and the Environment (South Africa)
Kind
Government
Scope
Specialist
Home region
South Africa
Edition
gef-2024 + nir-1990-2024-draft
Licence
Restricted licence (dffe-za-website-terms)

What open-climate.ai standardised

over the publisher's own fileHow we standardise
6 more things standardised

Languages

English: 100.0% of factor values

German: 100.0% of factor values

French: 100.0% of factor values

Norwegian Bokmål: 7.9% of factor values

Thai: 2.6% of factor values

Audit checks

145 passed1 known limitation3 enforced when loadedlast run 17 Nov 2026

Checks we run on every load to keep the data above trustworthy. Counts are for this library; the grey figure is the same check across all libraries. Point at the i to see why a check matters.

What the statuses meanHow checks are countedWhy we checkHow checks are grouped

Needs attention

  • Where a library breaks its totals down by gas, every total is broken down or reviewed

    Known limitation · 12 in this library · 693 in all libraries

One category axis

Learn more
  • Every source category maps to our vocabulary

    Enforced when loaded

  • The publisher's classification is kept

    Passed

  • Every classification level has a valid parent

    Passed

  • Every product code comes with the codes above it

    Passed

  • A publisher's own classification is used only by that publisher

    Passed

  • A standard classification code has one label in every library

    Passed

Coded regions

Learn more
  • Every region is a known code

    Enforced when loaded

  • No named region is filed under a broader one

    Passed

  • Every region sits in the world hierarchy

    Passed

Canonical units

Learn more
  • Every unit is a known code

    Enforced when loaded

  • One source unit maps to one unit

    Passed

  • A unit label means the same in every library

    Passed

  • A unit label that names no basis folds one way

    Passed · 2 in all libraries

Declared boundaries

Learn more
  • Every boundary states what it includes

    Passed

  • Boundary scope terms are known codes

    Passed

  • No two factors for the same activity partly overlap in scope

    Passed

  • Separate stages of one activity are linked as parts, or documented as having no total

    Passed

  • Every part of a factor states its boundary

    Passed

  • Every biofuel counted with its biogenic CO2 says how much

    Passed

  • No recycling credit is hidden inside a life-cycle total

    Passed

  • No burden value hides a sizeable credit inside it

    Passed · 13 in all libraries

Warming potentials

Learn more
  • Methane and nitrous oxide figures match the stated GWP

    Passed

  • Every convertible value has its AR6 version

    Passed

  • CO2e totals leave out what their basis excludes

    Passed

  • Where a library breaks its totals down by gas, every total is broken down or reviewed

    Known limitation · 12 in this library · 693 in all libraries

  • Standardised figures keep every gas the publisher lists

    Passed

  • Every value states what its CO2e total includes

    Passed

  • A library with no AR6 version at all has a recorded reason

    Passed

Electricity mix

Learn more
  • Every electricity factor states its mix

    Passed

  • The market-based value is the default

    Passed

  • One default value per factor and year

    Passed

  • Every green-electricity zero is a market-based value

    Passed

  • Green-electricity zeros are not rated below market-based peers

    Passed

Data quality

Learn more
  • Quality ratings fall inside their scale

    Passed

  • Every zero value is explained

    Passed

  • No default value is withheld without a stated reason

    Passed

  • No implausibly high per-kilogram value is rated reliable

    Passed

  • Every quality level gives a recognised reason

    Passed

  • A zero that is only a gap in the source is withheld

    Passed

  • The library is not rated entirely on one fallback quality level

    Passed

Languages

Learn more
  • Every factor has an English name

    Passed

  • Translations match the current source text

    Passed · 36 in all libraries

  • Translations follow a corrected source text

    Passed · 1 in all libraries

  • Recorded translations survive a reload

    Passed

  • Every served factor has a name

    Passed

  • Each factor's name is its English name or the publisher's own, never a mix of both

    Passed · 2 in all libraries

  • Every language with a main name also has a full name

    Passed

  • Full names are built from their parts in the same language

    Passed

  • Every text is labelled with its real language

    Passed

  • Every description is available for display and translation

    Passed

  • Every usage note is available for display and translation

    Passed

Traceable to the source

Learn more
  • Values traced to one source row agree with each other

    Passed

  • No duplicate factors are served

    Passed

  • No factor value claims two things that cannot both be true

    Passed

  • No energy factor answers a question about packaging or recycling

    Passed

  • Every served value past its publisher's end date has been reviewed

    Passed · 9 in all libraries

Other checks

  • One activity keeps one family across its units

    Passed · 8 in all libraries

  • An activity's grouping key names only the activity

    Passed · 2 in all libraries

  • A Creative Commons credit names its licence

    Passed

  • No note of ours appears in the credit or licence notice

    Passed

  • The credit line carries no terms of use

    Passed

  • Every part links to a valid parent

    Passed

  • Every impact assessment method is a recognised code

    Passed

  • Summed totals keep their parts' classification

    Passed

  • Every summed total has a classification when its parts do

    Passed

  • An avoided credit is linked to the burden it belongs to

    Passed

  • Every value is typed as specific, generic or average

    Passed

  • Summed totals equal their parts on every gas

    Passed

  • No total is served when one of its parts is withheld

    Passed

  • Validity dates are the publisher's own, never guessed

    Passed

  • Every district-heat factor says whether the network's heat loss is included

    Passed · 2 in all libraries

  • Quality breakdowns use their scheme's axes

    Passed

  • No battery-electric vehicle carries tailpipe emissions

    Passed

  • The text of each estimated electricity total matches its current figures

    Passed

  • No EPD value is wildly off its peers without a review

    Passed

  • Every estimated factor carries its description in each language

    Passed

  • The text of each estimated factor matches its current figures

    Passed

  • A total built on an estimated part is marked as estimated

    Passed

  • Every estimated district-heat leg still adds up from its sources

    Passed

  • Every estimate is built only from data we may redistribute

    Passed

  • No estimated factor is rated above the data it was built from

    Passed

  • No estimate sits beside a total of unclear scope

    Passed

  • No estimate repeats a stage the publisher's total already includes

    Passed

  • Every factor we complete has all of its estimated parts

    Passed · 247 in all libraries

  • No estimate is served where the publisher printed the figure

    Passed

  • We only estimate for publishers whose rule allows it

    Passed

  • Every estimated factor still matches the inputs it was computed from

    Passed

  • No estimated total competes with a published one

    Passed

  • Every factor with a current value has a default

    Passed

  • Every factor has a value, in a library that publishes values

    Passed

  • Only food, farming and land factors carry a FLAG split

    Passed

  • Every FLAG land-use change figure states its method and time frame

    Passed

  • Every total equals the sum of its SBTi FLAG split

    Passed

  • Every FLAG split says whether it was published or derived

    Passed

  • Fossil-only CO2 is filed as fossil

    Passed

  • The text of each fuel supply-chain estimate matches its current figures

    Passed

  • No fuel supply-chain estimate is rated above what its method allows

    Passed

  • Every fuel estimate is built only from data we may redistribute

    Passed

  • Every fuel eligible for a supply-chain estimate is classified

    Passed

  • No fuel estimate is served where the publisher printed the supply-chain figure

    Passed

  • No supply-chain estimate is served for a fuel we deliberately left out

    Passed

  • Every fuel supply-chain estimate still matches the figures it was computed from

    Passed

  • Per-gas values are in CO2e

    Passed

  • Every tagged gas has a known GWP

    Passed

  • Every fixed group of regions lists what it covers

    Passed

  • Where both exist, the residual mix is shown before the green-tariff zero

    Passed

  • The newest edition of each value is the one marked current

    Passed

  • Every publisher has a rule on whether we estimate its missing parts

    Passed

  • Factor descriptions describe the factor, not the whole library

    Passed

  • Every library's licence has its rights recorded

    Passed

  • No fossil electricity mix has a zero fuel supply chain

    Passed

  • Every green-electricity zero is exactly zero and says why

    Passed

  • Green-electricity zeros cover power generation only

    Passed

  • Only a total we computed may mix GWP vintages

    Passed

  • Spend factors state their price year and basis

    Passed

  • No electricity or heat factor answers network losses against its stage

    Passed

  • Every value has a number, a GWP version and a reference year

    Passed

  • Only a library cleared for it lists factors without their number

    Passed

  • Plug-in hybrid factors say when the electricity is left out

    Passed

  • A published total missing its fuel supply chain comes with a complete sum

    Passed

  • Product footprints headline fossil carbon, like EPDs

    Passed

  • No factor description is too long to display in full

    Passed · 11 in all libraries

  • The library-wide answers on what a factor covers are up to date

    Passed

  • Every library-wide answer applies to at least one factor

    Passed

  • Every excused arithmetic disagreement still matches the published figures

    Passed

  • Every reference year falls between 1960 and next year

    Passed

  • Each library's current edition is the one its values come from

    Passed

  • No two editions of a library share a release date

    Passed

  • The parts of a total are never listed twice under one label

    Passed

  • Every residual mix has its green-tariff counterpart

    Passed

  • Every factor points to its top parent

    Passed

  • Every conservative value carries the same label

    Passed

  • Every publisher's quality rating system is read

    Passed

  • Every factor's boundary includes what its category measures

    Passed

  • Every factor uses the most precise boundary for its category

    Passed

  • Every factor is filed under the most specific category its source allows

    Passed · 7,103 in all libraries

  • Every factor has a category

    Passed

  • Every categorised factor has a GHG Protocol scope

    Passed · 39 in all libraries

  • Single-gas values have their AR6 version

    Passed · 10 in all libraries

  • No factor answers a question that does not arise for it

    Passed · 9 in all libraries

  • No part is larger than the total it belongs to

    Passed

  • A supplier named in the source is linked to the factor

    Passed

  • No factor is an unlinked part of another factor

    Passed

  • A part covering the same scope as its total is linked to it

    Passed

  • Every device total that includes its use also gives the manufacturing share (embodied emissions)

    Passed · 115 in all libraries

  • Every estimated vehicle fuel-supply leg matches its sources

    Passed

  • No plug-in vehicle supply-chain estimate is rated above what its method allows

    Passed

  • Every exhaust-only vehicle factor gets a fuel-supply leg or a recorded reason

    Passed

  • A year in a factor's name matches its reference year

    Passed

How the audit works

What can I do with this data?

Restricted licence · credit the publisher

grid-ef

Restricted licence · dffe-za-website-terms
Use it to calculate my own footprint
Yes, if
  • you credit the publisher
Publish my footprint results
Yes, if
  • you credit the publisher

Publisher's published terms, checked on 3 Nov 2026

DFFE Terms of Use §1: users may view, copy, download, print and "distribute the content of this website, or any part thereof only for non-commercial informational or reference purposes"; commercial use needs the web manager's prior written permission; "© DFFE 2020: ALL RIGHTS RESERVED". The 2024 grid report (p14) is written for corporate Scope 2 reporting, so an own footprint and a published result with attribution are its stated use.

Credit line

Source: Department of Forestry, Fisheries and the Environment (DFFE), South Africa's Grid Emission Factors Report 2024 (Government Gazette No. 55353, GN 7891). Normalised by open-climate.ai, https://open-climate.ai/factors/libraries/dffe_za/ (CC BY 4.0)

Not legal advice: the publisher's terms prevail.

Full terms

nir

Restricted licence · dffe-za-website-terms
Use it to calculate my own footprint
Yes, if
  • you credit the publisher
Publish my footprint results
Yes, if
  • you credit the publisher

Publisher's published terms, checked on 3 Nov 2026

DFFE Terms of Use §1: users may view, copy, download, print and "distribute the content of this website, or any part thereof only for non-commercial informational or reference purposes"; commercial use needs the web manager's prior written permission; "© DFFE 2020: ALL RIGHTS RESERVED". The 2024 grid report (p14) is written for corporate Scope 2 reporting, so an own footprint and a published result with attribution are its stated use.

Credit line

Source: Department of Forestry, Fisheries and the Environment (DFFE), National GHG Inventory Report for South Africa 1990-2024, draft (Government Gazette No. 54758, GN 7537). Normalised by open-climate.ai, https://open-climate.ai/factors/libraries/dffe_za/ (CC BY 4.0)

Not legal advice: the publisher's terms prevail.

Full terms

How to read these answers

Coverage

Browse factors

top 0 matches

SavedUnfoldFactorRegionBoundary
Unit
VersionPublishedLoadedStatusSource
gef-2024grid-ef11 Sept 20263 Nov 2026ServedSource
nir-1990-2024-draftnir29 May 20263 Nov 2026ServedSource

Methodology

How this works
  • The grid report prints two generation factors for each year. The domestic generation factor (DGGEF) covers the power plants in South Africa. The national generation factor (NGGEF) adds the electricity imported from neighbouring countries, at their own intensity, and is the factor the report tells companies to use for Scope 2. Neither includes the losses of the network.
  • The losses are printed as two factors of their own: transmission losses and technical distribution losses, per MWh. For 2024 they are 0.021 and 0.071 t CO2e per MWh, 2.2 % and 7.4 % of the national generation factor, as the report states.
  • Grid values are t CO2e per MWh, which is the same number as kg CO2e per kWh. They use the IPCC Second Assessment Report (SAR) 100-year GWPs, as the report's footnotes say. Each value takes its data year, 2021 to 2024.
  • Fuel factors are kg of fossil CO2 per TJ of fuel on a net calorific value basis, from a South African study of the fuels sold in the country. They cover combustion only: no methane, no nitrous oxide, no fuel chain. We convert them to kg CO2 per kWh of fuel.
  • Livestock factors are kg of methane per head and year from enteric fermentation, worked out by the inventory for each herd. We weight the methane at 27, the IPCC Sixth Assessment Report (AR6) value for biogenic methane, and keep the printed methane mass beside the total. The inventory itself reports in AR5; we do not re-apply that.
  • Fuel and livestock factors take 2024, the last inventory year they are applied to.

Data year: the generation year of each grid column (2021-2024); on the national inventory factors, 2024, the last inventory year they are applied to.

What we import

  • From the grid report: 3 factors and 16 values. One generation factor with the domestic and the national figure for each of the four years, and the two loss factors for each year. The national figure is the default.
  • From the draft inventory: 13 fuel factors (8 liquid fuels, 4 coals and natural gas) and 22 livestock factors (dairy and other cattle, sheep, goats and swine, by herd).
  • In all, 38 factors and 51 values, every one for South Africa.
  • Not imported: a sensitivity case and the regional baseline from the UN Clean Development Mechanism that the grid report also prints, and its export factor, which repeats the national figure. From the inventory, the 11 fuel rows and the horse and mule rows that only reprint IPCC defaults, and the coal mining factors, printed in cubic metres of gas per tonne of coal with no gas density.
  • Each row's printed figures, the IPCC defaults the inventory prints beside its own fuel factors, and the source of each livestock factor are kept in our archive.
  • Names are the publisher's English, with French and German machine translations.

Restricted. The reports carry no licence of their own, so DFFE's website terms of use apply. They allow users to "view, copy, download to a local drive, print and distribute the content of this website, or any part thereof only for non-commercial informational or reference purposes", and commercial use needs "the prior written permission obtained from the web manager".

We read the terms as allowing you to use a factor for your own footprint and to publish your results, with attribution: the grid report is written for exactly that. Sharing the values with customers, embedding them in a product, and modifying or combining them all need permission. For the same reason we do not add estimated network or fuel-chain parts to these factors.

open-climate.ai lists these factors with their metadata; the values are withheld until the publisher agrees to their publication. The credit line is "Source: Department of Forestry, Fisheries and the Environment (DFFE), South Africa's Grid Emission Factors Report 2024 (Government Gazette No. 55353, GN 7891)" for the grid factors, and "Source: Department of Forestry, Fisheries and the Environment (DFFE), National GHG Inventory Report for South Africa 1990-2024, draft (Government Gazette No. 54758, GN 7537)" for the inventory factors. Last verified 2026-11-03.

What can I do with this data?

Credit line: Source: Department of Forestry, Fisheries and the Environment (DFFE), National GHG Inventory Report for South Africa 1990-2024, draft (Government Gazette No. 54758, GN 7537)

dffe-za-website-terms

Users may view, copy, download to a local drive, print and distribute the content of this website, or any part thereof only for non-commercial informational or reference purposes. Users who wish to use content from this site for commercial purposes may only do so with the prior written permission obtained from the web manager.

Limitations

  • DFFE prints no uncertainty and no quality rating. All 51 values are rated medium on the library's standing. How quality tiers work.
  • The inventory is a draft, published for comment; its factors may change in the final report.
  • The fuel factors are combustion CO2 only and the livestock factors are methane only: compare them with factors of the same scope.
  • The grid factors use SAR GWPs, older than the AR5 or AR6 values most libraries use. The report prints no split by gas, so they cannot be restated.
  • In its prose the inventory puts sub-bituminous coal 0.2 % above the IPCC default; its table gives 0.7 %. We load the table.
  • There is no machine-readable file. Our values come from a transcription of the two PDFs, checked against their own sums and ratios.

Changelog

  • 2026-11-03: Grid Emission Factors Report 2024 and the country-specific factors of the draft 1990-2024 inventory loaded.

Know a newer edition?

If DFFE has published an edition we do not serve yet, tell us where to find it.