SEAI - Sustainable Energy Authority of Ireland

Ireland's national CO2 factors for 19 fuels and for grid electricity, year by year from 2001 to 2025, from the conversion and emission factors workbook of the Sustainable Energy Authority of Ireland (SEAI).

Government
  • Grid mix
  • Electricity
SpecialistRestricted licence
Factors
49
Values
1,225

One per year and method

Countries
1

1 region, sub-national included

Edition
V1.7

published 19 Jun 2026 · all versions

Last loaded
3 Nov 2026

Report a newer version

Overview

SEAI is Ireland's national energy authority. Its Energy Statistics Team publishes, on the SEAI website, a workbook of conversion and emission factors at a fixed address, revised in place: a CO2 factor per fuel and for electricity for every year since 2001, with the energy content, density and primary energy factor of each fuel. The workbook keeps a version log. A new data year is added each June, and one or two corrections a year can restate past years. The edition loaded is version 1.7 of 19 June 2026, which added the 2025 values and restated the whole electricity series.

At a glance

Publisher
Sustainable Energy Authority of Ireland
Kind
Government
Scope
Specialist
Home region
Ireland
Edition
V1.7
Licence
Restricted licence (seai-site-terms)

What open-climate.ai standardised

over the publisher's own fileHow we standardise

Warming potentials

0 factor values recalculated on AR6

0 factor values already on AR6

42 factor values left on the publisher's GWP

7 factor values the same on every GWP

8 more things standardised

Estimated fuel legs

14 estimated supply-chain legs (well-to-tank) the publisher does not print

14 totals over burning and supply

Languages

English: 100.0% of factor values

German: 100.0% of factor values

French: 100.0% of factor values

Norwegian Bokmål: 6.1% of factor values

Thai: 24.5% of factor values

Audit checks

146 passed3 enforced when loadedlast run 17 Nov 2026

Checks we run on every load to keep the data above trustworthy. Counts are for this library; the grey figure is the same check across all libraries. Point at the i to see why a check matters.

What the statuses meanHow checks are countedWhy we checkHow checks are grouped

One category axis

Learn more
  • Every source category maps to our vocabulary

    Enforced when loaded

  • The publisher's classification is kept

    Passed

  • Every classification level has a valid parent

    Passed

  • Every product code comes with the codes above it

    Passed

  • A publisher's own classification is used only by that publisher

    Passed

  • A standard classification code has one label in every library

    Passed

Coded regions

Learn more
  • Every region is a known code

    Enforced when loaded

  • No named region is filed under a broader one

    Passed

  • Every region sits in the world hierarchy

    Passed

Canonical units

Learn more
  • Every unit is a known code

    Enforced when loaded

  • One source unit maps to one unit

    Passed

  • A unit label means the same in every library

    Passed

  • A unit label that names no basis folds one way

    Passed · 2 in all libraries

Declared boundaries

Learn more
  • Every boundary states what it includes

    Passed

  • Boundary scope terms are known codes

    Passed

  • No two factors for the same activity partly overlap in scope

    Passed

  • Separate stages of one activity are linked as parts, or documented as having no total

    Passed

  • Every part of a factor states its boundary

    Passed

  • Every biofuel counted with its biogenic CO2 says how much

    Passed

  • No recycling credit is hidden inside a life-cycle total

    Passed

  • No burden value hides a sizeable credit inside it

    Passed · 13 in all libraries

Warming potentials

Learn more
  • Methane and nitrous oxide figures match the stated GWP

    Passed

  • Every convertible value has its AR6 version

    Passed

  • CO2e totals leave out what their basis excludes

    Passed

  • Where a library breaks its totals down by gas, every total is broken down or reviewed

    Passed · 693 in all libraries

  • Standardised figures keep every gas the publisher lists

    Passed

  • Every value states what its CO2e total includes

    Passed

  • A library with no AR6 version at all has a recorded reason

    Passed

Parts and parents

Learn more
  • Every part links to a valid parent

    Passed

  • No factor is an unlinked part of another factor

    Passed

  • No part is larger than the total it belongs to

    Passed

  • Every factor points to its top parent

    Passed

Estimated fuel legs

Learn more
  • No fuel estimate is served where the publisher printed the supply-chain figure

    Passed

  • No supply-chain estimate is served for a fuel we deliberately left out

    Passed

  • Every fuel estimate is built only from data we may redistribute

    Passed

  • No fuel supply-chain estimate is rated above what its method allows

    Passed

  • Every fuel eligible for a supply-chain estimate is classified

    Passed

  • Every fuel supply-chain estimate still matches the figures it was computed from

    Passed

  • The text of each fuel supply-chain estimate matches its current figures

    Passed

Electricity mix

Learn more
  • Every electricity factor states its mix

    Passed

  • The market-based value is the default

    Passed

  • One default value per factor and year

    Passed

  • Every green-electricity zero is a market-based value

    Passed

  • Green-electricity zeros are not rated below market-based peers

    Passed

Data quality

Learn more
  • Quality ratings fall inside their scale

    Passed

  • Every zero value is explained

    Passed

  • No default value is withheld without a stated reason

    Passed

  • No implausibly high per-kilogram value is rated reliable

    Passed

  • Every quality level gives a recognised reason

    Passed

  • A zero that is only a gap in the source is withheld

    Passed

  • The library is not rated entirely on one fallback quality level

    Passed

Languages

Learn more
  • Every factor has an English name

    Passed

  • Translations match the current source text

    Passed · 36 in all libraries

  • Translations follow a corrected source text

    Passed · 1 in all libraries

  • Recorded translations survive a reload

    Passed

  • Every served factor has a name

    Passed

  • Each factor's name is its English name or the publisher's own, never a mix of both

    Passed · 2 in all libraries

  • Every language with a main name also has a full name

    Passed

  • Full names are built from their parts in the same language

    Passed

  • Every text is labelled with its real language

    Passed

  • Every description is available for display and translation

    Passed

  • Every usage note is available for display and translation

    Passed

Traceable to the source

Learn more
  • Values traced to one source row agree with each other

    Passed

  • No duplicate factors are served

    Passed

  • No factor value claims two things that cannot both be true

    Passed

  • No energy factor answers a question about packaging or recycling

    Passed

  • Every served value past its publisher's end date has been reviewed

    Passed · 9 in all libraries

Other checks

  • One activity keeps one family across its units

    Passed · 8 in all libraries

  • An activity's grouping key names only the activity

    Passed · 2 in all libraries

  • A Creative Commons credit names its licence

    Passed

  • No note of ours appears in the credit or licence notice

    Passed

  • The credit line carries no terms of use

    Passed

  • Every impact assessment method is a recognised code

    Passed

  • Summed totals keep their parts' classification

    Passed

  • Every summed total has a classification when its parts do

    Passed

  • An avoided credit is linked to the burden it belongs to

    Passed

  • Every value is typed as specific, generic or average

    Passed

  • Summed totals equal their parts on every gas

    Passed

  • No total is served when one of its parts is withheld

    Passed

  • Validity dates are the publisher's own, never guessed

    Passed

  • Every district-heat factor says whether the network's heat loss is included

    Passed · 2 in all libraries

  • Quality breakdowns use their scheme's axes

    Passed

  • No battery-electric vehicle carries tailpipe emissions

    Passed

  • The text of each estimated electricity total matches its current figures

    Passed

  • No EPD value is wildly off its peers without a review

    Passed

  • Every estimated factor carries its description in each language

    Passed

  • The text of each estimated factor matches its current figures

    Passed

  • A total built on an estimated part is marked as estimated

    Passed

  • Every estimated district-heat leg still adds up from its sources

    Passed

  • Every estimate is built only from data we may redistribute

    Passed

  • No estimated factor is rated above the data it was built from

    Passed

  • No estimate sits beside a total of unclear scope

    Passed

  • No estimate repeats a stage the publisher's total already includes

    Passed

  • Every factor we complete has all of its estimated parts

    Passed · 247 in all libraries

  • No estimate is served where the publisher printed the figure

    Passed

  • We only estimate for publishers whose rule allows it

    Passed

  • Every estimated factor still matches the inputs it was computed from

    Passed

  • No estimated total competes with a published one

    Passed

  • Every factor with a current value has a default

    Passed

  • Every factor has a value, in a library that publishes values

    Passed

  • Only food, farming and land factors carry a FLAG split

    Passed

  • Every FLAG land-use change figure states its method and time frame

    Passed

  • Every total equals the sum of its SBTi FLAG split

    Passed

  • Every FLAG split says whether it was published or derived

    Passed

  • Fossil-only CO2 is filed as fossil

    Passed

  • Per-gas values are in CO2e

    Passed

  • Every tagged gas has a known GWP

    Passed

  • Every fixed group of regions lists what it covers

    Passed

  • Where both exist, the residual mix is shown before the green-tariff zero

    Passed

  • The newest edition of each value is the one marked current

    Passed

  • Every publisher has a rule on whether we estimate its missing parts

    Passed

  • Factor descriptions describe the factor, not the whole library

    Passed

  • Every library's licence has its rights recorded

    Passed

  • No fossil electricity mix has a zero fuel supply chain

    Passed

  • Every green-electricity zero is exactly zero and says why

    Passed

  • Green-electricity zeros cover power generation only

    Passed

  • Only a total we computed may mix GWP vintages

    Passed

  • Spend factors state their price year and basis

    Passed

  • No electricity or heat factor answers network losses against its stage

    Passed

  • Every value has a number, a GWP version and a reference year

    Passed

  • Only a library cleared for it lists factors without their number

    Passed

  • Plug-in hybrid factors say when the electricity is left out

    Passed

  • A published total missing its fuel supply chain comes with a complete sum

    Passed

  • Product footprints headline fossil carbon, like EPDs

    Passed

  • No factor description is too long to display in full

    Passed · 11 in all libraries

  • The library-wide answers on what a factor covers are up to date

    Passed

  • Every library-wide answer applies to at least one factor

    Passed

  • Every excused arithmetic disagreement still matches the published figures

    Passed

  • Every reference year falls between 1960 and next year

    Passed

  • Each library's current edition is the one its values come from

    Passed

  • No two editions of a library share a release date

    Passed

  • The parts of a total are never listed twice under one label

    Passed

  • Every residual mix has its green-tariff counterpart

    Passed

  • Every conservative value carries the same label

    Passed

  • Every publisher's quality rating system is read

    Passed

  • Every factor's boundary includes what its category measures

    Passed

  • Every factor uses the most precise boundary for its category

    Passed

  • Every factor is filed under the most specific category its source allows

    Passed · 7,103 in all libraries

  • Every factor has a category

    Passed

  • Every categorised factor has a GHG Protocol scope

    Passed · 39 in all libraries

  • Single-gas values have their AR6 version

    Passed · 10 in all libraries

  • No factor answers a question that does not arise for it

    Passed · 9 in all libraries

  • A supplier named in the source is linked to the factor

    Passed

  • A part covering the same scope as its total is linked to it

    Passed

  • Every device total that includes its use also gives the manufacturing share (embodied emissions)

    Passed · 115 in all libraries

  • Every estimated vehicle fuel-supply leg matches its sources

    Passed

  • No plug-in vehicle supply-chain estimate is rated above what its method allows

    Passed

  • Every exhaust-only vehicle factor gets a fuel-supply leg or a recorded reason

    Passed

  • A year in a factor's name matches its reference year

    Passed

How the audit works

What can I do with this data?

Restricted licence · credit the publisher

Your rights

Restricted licence · seai-site-terms
Use it to calculate my own footprint
Yes
Publish my footprint results
Yes, if
  • you credit the publisher
Modify it or combine it with my own data
Ask Sustainable Energy Authority of Ireland (SEAI)

Our reading, where no written grant settles it, checked on 3 Nov 2026

seai.ie legal notice: the site's content may not be reproduced without SEAI's prior written permission; no data licence is attached to the conversion-factors workbook. Owner decision S1 = A (2026-11-03): load at restricted, ask SEAI for written terms (email sent 2026-10-27, no reply yet).

Credit line

Source: Sustainable Energy Authority of Ireland (SEAI), Conversion and emission factors. Normalised by open-climate.ai, https://open-climate.ai/factors/libraries/seai/ (CC BY 4.0)

Not legal advice: the publisher's terms prevail.

Full terms

How to read these answers

Coverage

Browse factors

top 0 matches

SavedUnfoldFactorRegionBoundary
Unit

Checked for updates 17 Nov 2026: the publisher still shows the edition we serve (2 signals watched)

VersionPublishedLoadedStatusSource
V1.719 Jun 20263 Nov 2026ServedSource

Methodology

How this works
  • Only CO2 is counted. The workbook states that the factors leave out methane and nitrous oxide, and points to the national inventory submissions of Ireland's Environmental Protection Agency for them. It names no GWP set. The CO2e we serve is that CO2 alone.
  • Fuel factors are the direct CO2 of burning the fuel, nothing upstream. They are printed in grams of CO2 per kWh of fuel on the net calorific value, unless a row says otherwise. Natural gas is printed on both bases, gross and net, and is loaded as two factors of the same fuel.
  • The CO2 of sustainable biomass is counted as zero. Biodiesel (methyl ester) counts its 5.4% of fossil carbon, the share used in the national inventory. Road diesel and road petrol are the national average blends, so their factors fall as the biofuel share grows: road diesel prints 263.9 g per kWh in 2001 and 239.0 in 2025, against 263.9 for pure diesel.
  • Electricity counts only the CO2 emitted in Ireland by power generation. Imported electricity counts as zero. Two series divide that CO2 by two different amounts of electricity. The electricity consumption factor divides it by the electricity available for final consumption, so it includes the transmission and distribution losses and the plants' own use; SEAI gives it for electricity consumption. The gross electricity supply factor divides it by gross production in Ireland (storage output excluded) plus net imports; SEAI gives it for generation only. We file the first as generation plus network losses and the second as generation.
  • The 2025 electricity values are provisional, as the workbook notes, and carry a preliminary qualifier.
  • Values are served per kWh, converted from grams at 0.001.
  • The reference year of a value is the year of its column in the workbook.

Data year: the column year of the SEAI time series (2001-2025).

What we import

  • 21 factors and 525 values, all for Ireland, one value for every year from 2001 to 2025.
  • 19 fuel factors: 9 liquid fossil fuels (crude oil, petrol, kerosene, jet kerosene, diesel and gasoil, residual fuel oil, LPG and the road diesel and road petrol blends), 7 solid fossil fuels (petroleum coke, bituminous coal, anthracite, lignite, milled peat, sod peat and peat briquettes), natural gas on its two bases, and biodiesel.
  • 2 grid electricity factors, electricity consumption and gross electricity supply.
  • Factor names are the workbook's own English labels. The notes printed beside a row (the fossil share of biodiesel, the milled peat note, what each electricity series includes) are kept as the factor's description.
  • The energy content and density of each fuel, year by year, are kept as unit conversions, so a fuel factor can also be applied per kilogram, per litre or, for natural gas, per cubic metre, with that year's own figures.
  • Factors are placed in the open-climate.ai category tree: grid electricity, and under fuels 9 liquid fossil, 7 solid fossil, 2 gaseous fossil and 1 biofuel.
  • Not loaded: 7 rows that print a dash in every year, five liquid biofuels (bioethanol, two kinds of hydrotreated vegetable oil, biopropane and biojet) and two wood fuels. They carry no number, so nothing is lost. Also not loaded: the primary energy factors, the 2025 summary sheet, which repeats the timeseries, and the helper sheets behind the blends and the electricity series.

The fuel factors cover combustion only. Beside 14 of the fossil fuel factors, open-climate.ai adds an estimated well-to-tank leg (the emissions of extracting, processing and transporting the fuel) and a well-to-use total, each as its own factor marked as an estimate. The leg is the published combustion factor times the ratio of well-to-tank to combustion emissions for the same fuel. Natural gas on both bases, anthracite and bituminous coal take the EU average of the JEC Well-to-Tank report (version 5, for 2020); the other ten take the ratio from the UK Government's 2026 greenhouse gas conversion factors. Every leg is rated very low quality. Biodiesel gets none, since its value leaves out its biogenic CO2, nor do crude oil and the three peats, for which no source prints both a combustion and a well-to-tank figure. Electricity gets no leg: SEAI publishes no well-to-tank figure for it, and we add none until SEAI confirms its terms of reuse. The legs and totals carry the same terms as SEAI's factors. SEAI's own numbers are unchanged: leave out estimated factors (is_estimated) to keep them only. How the fuel legs are estimated.

Restricted. The workbook carries no licence and no notice of its own. SEAI's site terms allow the use of its documents "for information and/or personal use only", state that "No part of this site may be reproduced or stored in any other site or included in any public or private electronic retrieval system or service without the Sustainable Energy Authority of Ireland's prior written permission", and reserve "Any rights not expressly granted". Using the factors for your own footprint is allowed: the workbook's own notes say to use them to calculate CO2 emissions. Publishing results is allowed with SEAI named as the source. Sharing the values with customers and embedding them in a product are not granted, so we record them as unclear, and modifying or combining the values needs SEAI's permission. We have asked SEAI for written terms and have no answer yet. Until SEAI grants reuse in writing, the factors are listed and searchable with their descriptions, and the values are not shown on the public site; the estimated legs and totals are restricted with them. Attribution: "Source: Sustainable Energy Authority of Ireland (SEAI), Conversion and emission factors." Last verified 2026-11-03.

What can I do with this data?

Credit line: Source: Sustainable Energy Authority of Ireland (SEAI), Conversion and emission factors

seai-site-terms

No part of this site may be reproduced or stored in any other site or included in any public or private electronic retrieval system or service without the Sustainable Energy Authority of Ireland's prior written permission

Limitations

  • CO2 only. Methane and nitrous oxide from combustion, and every upstream emission, are left out, so these factors understate a full greenhouse gas footprint. The estimated well-to-tank legs we add cover 14 fossil fuels, and are in CO2e on the GWP set of their source (AR4 for the JEC ratios, AR5 for the UK ones).
  • The electricity factors count Irish emissions only: imports count as zero, and the fuel supply chain of the power plants is not included. They are location-based national averages and do not reflect green power purchases or a supplier's own mix.
  • SEAI revises the workbook in place, at the same address, and its corrections restate past years: version 1.7 restated the whole electricity series. A later download can print different numbers for the same year, and the 2025 electricity values are still provisional.
  • Some recent years repeat the year before. Milled peat prints its 2023 value for 2024 and 2025, as its note says (it was last used in 2023); petroleum coke and natural gas print their 2024 value again for 2025, without a note. Thirteen fuels print the same value in every year from 2001 to 2025, among them crude oil, diesel, LPG and the coals.
  • Applying a factor on the net calorific basis to energy billed on a gross basis overstates emissions. For gas bills in gross kWh, use the natural gas factor on the gross basis.
  • SEAI's 525 values are rated medium quality: national averages per fuel, not measured at your plant. The estimated legs are rated very low. The well-to-use totals are rated medium, except those of lignite and petroleum coke, rated very low: the UK ratios behind their legs are the least certain of the set, and lignite borrows the ratio of industrial coal.
  • How quality tiers are set.

Changelog

  • 2026-11-03: version 1.7 loaded (data years 2001 to 2025, the 2025 electricity values provisional), restricted, with estimated well-to-tank legs and well-to-use totals beside 14 fossil fuel factors.

Know a newer edition?

If SEAI has published an edition we do not serve yet, tell us where to find it.