Emission factor from EPD Danmark EPD, product-specific
MicroVent, MV6, w. Internal screen
Europe · EPD total · Reference year 2026
Each unit of this product counts as 336 kg CO₂e over the modules its EPD declares: 106 to make it (A1–A3), 228 in use (B6) and 1.41 at end of life.
Value per unit, over the modules the EPD declares
336kgCO₂e/unit
EN 15804 modules A1 to B6 · Fossil only · GWP100 · AR5
Derived by open-climate.ai: the sum of EPD Danmark's published parts
The one scenario this EPD declaresReference year 2026
- Region
- Europe
- Boundary
- EPD total
- Data quality
- HighRated by us, not by the source
- Licence
- Open · EPD Danmark terms
- Declared by
- Maico Nordic A/S
Where 336 comes from
- A1-A3 Product stageScope 3, cat. 210631.7%
- Scope 1 Scope 2 Scope 3, cat. 322867.9%
- End of lifeDerived by open-climate.aiScope 3, cat. 51.410.4%
- Outside the scopes−11.3beside
Σ 336: the three declared modules add up to the total. D stays beside it.
Reporting this item under the GHG Protocol
This period
Scope 3, category 2 106
The product becomes part of a building you own. The product and its installation go to category 2 in the year you buy it, the delivery to category 4. Use and end of life are reported in the years they happen.
Later, when it happens
During use, in the years the building stands
- B6 Scope 1 Scope 2 Scope 3, category 3 228
At end of life, in the year of demolition
- End of life Scope 3, category 5 1.41
Outside the scopes, reported separately
- D −11.3
A4, A5, B1 to B5, B7 and C1 to C4 are not declared: nothing to report.
The factor, standardised
Every factor on open-climate.ai answers the same questions in the same words, whatever the publisher. Open any ⓘ for the definition.
Manufactured goods › Machinery · Europe · per item · Supplier-specific
EPD total · Fossil only · AR5
- BoundaryEPD totalThe sum of every EN 15804 module an EPD declares, when that set is not the complete A-C grid (MOD-0034). Learn more
- EPD total
- Raw materials, inbound transport, fuel supply, fuel combustion, manufacturing, packaging, purchased energy, use, maintenance and end of life
- GWP methodWhich IPCC assessment report's warming potentials convert each gas to CO₂e, and over how many years the warming is counted (GWP100: 100 years). Learn more
- IPCC AR5, 100-year horizon
- Not on the record; set from EPD Danmark's method notes · impact method EF 3.1
- CO₂e basisWhich carbon the CO₂e counts. Fossil only leaves out biogenic CO₂ and land use; net total counts every pool, net of removals. The same activity on two bases is two different numbers. Learn more
- Fossil only
- Split by carbon origin, not by gas
- Life cycle
- Upstream: coveredProduction: coveredDownstream: partly coveredEnd of life: partly covered
High quality · Open licence · Any year
Module by module, up to the total
Seventeen EN 15804 modules, always in the same order. Each declared one moves the running total. D sits below zero after the total, because it is reported beside it.
beside the total, not in it
| Module | Name | Per unit | Running total | Status |
|---|---|---|---|---|
| A1-A3 | Product stage | 106.42 | 106.42 | Declared |
| A4 | Transport to site | not declared | 106.42 | Not declared |
| A5 | Installation | not declared | 106.42 | Not declared |
| B1 | Use | not declared | 106.42 | Not declared |
| B2 | Maintenance | not declared | 106.42 | Not declared |
| B3 | Repair | not declared | 106.42 | Not declared |
| B4 | Replacement | not declared | 106.42 | Not declared |
| B5 | Refurbishment | not declared | 106.42 | Not declared |
| B6 | Energy in use | 228 | 334.42 | Declared |
| B7 | Water in use | not declared | 334.42 | Not declared |
| C1 | Demolition | not declared | 334.42 | Not declared |
| C2 | Waste transport | 0.035736 | 334.456 | Declared |
| C3 | Waste processing | 1.3707 | 335.826 | Declared |
| C4 | Disposal | 0.004273 | 335.831 | Declared |
| Total | EPD total, declared modules | 335.831 | Sum of the declared modules | |
| D | Beyond the system boundary | −11.346 | not added | Beside the total, not in it |
What this number covers
Follow 1 unit of this product through EN 15804's stages. The total counts what the EPD declares; what it leaves out stays visible.
A1-A3Product
Materials and making the product
Included106A4-A5Construction
Delivery and installation
Not declaredB1-B7Use
Energy in use only; B1 to B5, B7 not declared
B6 only228C1-C4End of life
Waste transport to disposal; C1 not declared
C2 to C41.41DBeyond the boundary
Recovery after end of life
Not in the total−11.3
Outside this boundary
- Installation
- Outbound transport
- Retail
- Recycling credit
The recycling credit is module D, shown beside the total.
Gases
- Fossil CO₂e336
- Biogenic CO₂e−4.07
- Land-use CO₂e0.234
The total counts fossil CO₂e. EPD Danmark reports biogenic and land-use CO₂e separately; they are shown beside it, not added.
From EPD Danmark's record to a comparable factor
EPD Danmark publishes this EPD with one value per module. Each field as printed, and what open-climate.ai made of it.
The total and its modules
Use a module on its own when you report it in a different year or scope; never add one to the total.
About this factor
From EPD Danmark
What it is
MicroVent is a decentralized ventilation system integrated in the building façade. Incl. Add-on Steel Screens for internal and external useWhat it includes
The air handling units follow the standards: EN 13141-7 / EN 13141-8. The declared products are used for demandcontrolled balanced, comfort ventilation with heat recovery in residential, office, institutional, and other occupancy and residential spaces. The product complies with applicable legal requirements for specific energy consumption (SEL value) and heat recovery. The products comply with Danish Building regulations BR 2018 and BK2020, Ecodesign and DS447. The products are tested and comply with the regulations according to DS/EN 13141-8 for one AHU unit: • Temperature efficiency The temperature efficiency test is according to DS/EN 13141-8: 8.1 General calculations and DS/EN 13141-8: 5.4.7.3 Thermal test and DS/EN 13141-8: 8.2 Special calculations for alternating exchangers. - w of the internal leakage (not measured) - x of the outdoor mixing (not measured) - y of the indoor mixing (not measured) - v of the air flow sensitivity (not measured) Delivery reservation (delimitation / limitation): This test was carried out according to DS/EN 13141 – 8. Further technical information can be obtained by contacting the manufacturer or on the manufacturer’s website: https://maico-nordic.dk/ Foreground system: The product is produced using a mix of Danish residual electricity mix from 2022 (76.12%) and electricity from solar panels on-site (23.88%) from 2023 in the production. Remaining energy processes is modelled using national electricity mixes from Managed LCA Content (MLC) database. Background system: Upstream processes are modelled using national energy mixes. Downstream processes are modelled using national energy mixes.Where it applies
MicroVent is a decentralized ventilation system integrated in the building façade. The principle of a micro-ventilation system is that at least two micro-ventilation units work together to exchange the air in a room. The units are coordinated in such a way that when one unit removes air, another unit will supply air to the room. Micro-ventilation can be used in most buildings and is particularly suitable for renovation projects due to its simple installation process - even in protected and historically valuable buildings.Source and licence
- Value
- Summed by open-climate.ai from its parts
- Publisher
- EPD Danmark (Teknologisk Institut)
- Published
- 2 October 2026
- Valid until
- 31 December 2029
The values and their metadata are served in full and may be reused with credit to the publisher.
Cite this factor
EPD Danmark (Teknologisk Institut), EPD data from https://data.epddanmark.dk. Normalised by open-climate.ai, https://open-climate.ai/factors/libraries/epd_danmark/ (CC BY 4.0). https://open-climate.ai/factors/ef-epddanmark-microvent_microvent_mv6-europe-unit-epd_total-a2ce5a7a/?v=efv1-bbea994619bd66188ed442e863111123
Something looks wrong?
Tell us which value and why. We check it against the source and answer within a week.