Emission factor from EPD Danmark EPD, product-specific
Presence & Motion Detectors Portfolio P40-M40 - Presence P42LR 230V 2ch M 32-37m FM
Europe · EPD total · Reference year 2025
Each unit of this product counts as 14.2 kg CO₂e over the modules its EPD declares: 4.62 in use (B6) and 9.54 for cradle to grave, embodied.
Value per unit, module B6 only
14.2kgCO₂e/unit
EN 15804 module B6 · Fossil only · GWP100 · AR5
Derived by open-climate.ai: the sum of EPD Danmark's published parts
The one scenario this EPD declaresReference year 2025
- Region
- Europe
- Boundary
- EPD total
- Data quality
- HighRated by us, not by the source
- Licence
- Open · EPD Danmark terms
- Declared by
- Wygwam Denmark A/S
Where 14.2 comes from
- Cradle to grave, embodiedDerived by open-climate.aiScope 3, cat. 1, 4 and 59.5467.4%
- Not yours to report4.6232.6%
- Outside the scopes−0.0384beside
Σ 14.2: the two declared modules add up to the total. D stays beside it.
Reporting this item under the GHG Protocol
This period
Scope 3, categories 1 and 4 9.54
This one figure covers both together; no split between them is given.
You buy the product for a building that is not yours. The product and its installation go to category 1, the delivery to category 4. The use stage belongs to the building owner; demolition waste you handle is category 5.
Later, when it happens
During use: the building owner reports it
- B6 Not yours to report 4.62
At end of life, in the year of demolition
- Cradle to grave, embodied Scope 3, category 5 9.54
Outside the scopes, reported separately
- D −0.0384
A1-A3 to A5, B1 to B5, B7 and C1 to C4 are not declared: nothing to report.
The factor, standardised
Every factor on open-climate.ai answers the same questions in the same words, whatever the publisher. Open any ⓘ for the definition.
Manufactured goods › Electrical equipment · Europe · per item · Supplier-specific
EPD total · Fossil only · AR5
- BoundaryEPD totalThe sum of every EN 15804 module an EPD declares, when that set is not the complete A-C grid (MOD-0034). Learn more
- EPD total
- Raw materials, inbound transport, fuel supply, fuel combustion, manufacturing, packaging, purchased energy, installation, outbound transport, use and end of life
- GWP methodWhich IPCC assessment report's warming potentials convert each gas to CO₂e, and over how many years the warming is counted (GWP100: 100 years). Learn more
- IPCC AR5, 100-year horizon
- Not on the record; set from EPD Danmark's method notes · impact method EF 3.1
- CO₂e basisWhich carbon the CO₂e counts. Fossil only leaves out biogenic CO₂ and land use; net total counts every pool, net of removals. The same activity on two bases is two different numbers. Learn more
- Fossil only
- Split by carbon origin, not by gas
- Life cycle
- Upstream: coveredProduction: coveredDownstream: partly coveredEnd of life: partly covered
High quality · Open licence · Any year
Module by module, up to the total
Seventeen EN 15804 modules, always in the same order. Each declared one moves the running total. D sits below zero after the total, because it is reported beside it.
beside the total, not in it
| Module | Name | Per unit | Running total | Status |
|---|---|---|---|---|
| A1-A3 | Product stage | 8.752 | 8.752 | Declared |
| A4 | Transport to site | 0.0992 | 8.8512 | Declared |
| A5 | Installation | 0.0123 | 8.8635 | Declared |
| B1 | Use | not declared | 8.8635 | Not declared |
| B2 | Maintenance | not declared | 8.8635 | Not declared |
| B3 | Repair | not declared | 8.8635 | Not declared |
| B4 | Replacement | not declared | 8.8635 | Not declared |
| B5 | Refurbishment | not declared | 8.8635 | Not declared |
| B6 | Energy in use | 4.62 | 13.4835 | Declared |
| B7 | Water in use | not declared | 13.4835 | Not declared |
| C1 | Demolition | not declared | 13.4835 | Not declared |
| C2 | Waste transport | 0.0318 | 13.5153 | Declared |
| C3 | Waste processing | 0.000903 | 13.5162 | Declared |
| C4 | Disposal | 0.64 | 14.1562 | Declared |
| Total | EPD total, declared modules | 14.1562 | Sum of the declared modules | |
| D | Beyond the system boundary | −0.0384 | not added | Beside the total, not in it |
What this number covers
Follow 1 unit of this product through EN 15804's stages. The total counts what the EPD declares; what it leaves out stays visible.
A1-A3Product
Materials and making the product
Included8.75A4-A5Construction
Delivery and installation
Included0.112B1-B7Use
Energy in use only; B1 to B5, B7 not declared
B6 only4.62C1-C4End of life
Waste transport to disposal; C1 not declared
C2 to C40.673DBeyond the boundary
Recovery after end of life
Not in the total−0.0384
Outside this boundary
- Maintenance
- Retail
- Recycling credit
Maintenance is out because B2 is not declared. The recycling credit is module D, shown beside the total.
Gases
- Fossil CO₂e14.2
- Biogenic CO₂e0.0508
- Land-use CO₂e0.156
The total counts fossil CO₂e. EPD Danmark reports biogenic and land-use CO₂e separately; they are shown beside it, not added.
From EPD Danmark's record to a comparable factor
EPD Danmark publishes this EPD as one declared value. Each field as printed, and what open-climate.ai made of it.
The total and its modules
Use a module on its own when you report it in a different year or scope; never add one to the total.
About this factor
From EPD Danmark
What it is
This presence detector is a DALI-2 master for DALI lighting control in up to 4 zones. The detector is fitted with multiple functions and can be controlled wirelessly using push buttons. The SnapFit mounting bracket ensures a quick and stable mounting in all types of suspended ceilings with or without removable tiles. The lighting zones are defined during commissioning, using the Niko detector tool app and 2-way Bluetooth® communication between a smartphone and the detector.What it includes
Presence detectors are covered by harmonised technical specifications: • CE: 93/68/EEC 22-07-1993 • RE: 2014/53/EU 16-04-2014 • RoHS: 2011/65/EU 08-06-2011 References to the relevant harmonized standards used or references to other technical specifications in relation to which conformity is declared: • RE EMC: o EN IEC 60669-2-1: 2022 o ETSI EN 301 489-17 V3.2.4 • RE safety: o EN IEC 60669-2-1: 2022 o EN 62479: 2010 • RE spectrum: ETSI EN 300 328 V2.2.2 • RoHS: EN IEC 63000: 2018 Foreground system: The energy used for these processes comes both from residual mix and solar energy in Thailand. Proof of solar energy usage comes from software reports the manufacturer owns. Background system: Upstream processes are modelled using the global grid mix. For some specific processes where it has been possible to define the specific electricity mix, these were modelled using the country-specific residual mix. Downstream processes are modelled using country-specific grid mix.Where it applies
To provide light control, over 10 years with 365 days operation and 24 operating hours per day. Presence detectors are devices installed in buildings that allow efficient lighting system administration, monitoring, and setup. They enable automated modifications and scenario settings, which improve energy efficiency and user comfort.Source and licence
- Value
- Summed by open-climate.ai from its parts
- Publisher
- EPD Danmark (Teknologisk Institut)
- Published
- 2 October 2026
- Valid until
- 31 December 2030
The values and their metadata are served in full and may be reused with credit to the publisher.
Cite this factor
EPD Danmark (Teknologisk Institut), EPD data from https://data.epddanmark.dk. Normalised by open-climate.ai, https://open-climate.ai/factors/libraries/epd_danmark/ (CC BY 4.0). https://open-climate.ai/factors/ef-epddanmark-presence_motion-europe-unit-epd_total-0905a81f/?v=efv1-2de4bc1f60313709aae22c7162cc7081
Something looks wrong?
Tell us which value and why. We check it against the source and answer within a week.