Emission factor from EPD Ireland EPD, product-specific

ProAir Mechanical Extract Ventilation Unit: ProAir FRPRO1 and ProAir FRPRO2

Ireland · Cradle to grave · Reference year 2022

Each unit of this product counts as 1,293 kg CO₂e over the modules its EPD declares: 911 in use (B4, B6) and 382 for cradle to grave, embodied.

Value per unit, over the modules the EPD declares

1,293kgCO₂e/unit

EN 15804 modules B4 to B6 · Fossil only · GWP100 · AR5

Derived by open-climate.ai: the sum of EPD Ireland's published parts

The one scenario this EPD declaresReference year 2022

Region
Ireland IE
Boundary
Cradle to grave
Data quality
HighRated by us, not by the source
Licence
Open · EPD Ireland terms
Declared by
ProAir Heat Recovery Ventilation Systems Ltd. T/A ProAir Systems

Where 1,293 comes from

Derived by open-climate.ai

Σ 1,293: the three declared modules add up to the total. D stays beside it.

Reporting this item under the GHG Protocol

This period

Scope 3, categories 2 and 4 382

This one figure covers both together; no split between them is given.

The product becomes part of a building you own. The product and its installation go to category 2 in the year you buy it, the delivery to category 4. Use and end of life are reported in the years they happen.

Later, when it happens

During use, in the years the building stands

  • B4 Scope 3, category 2 12.8
  • B6 Scope 1 Scope 2 Scope 3, category 3 898

At end of life, in the year of demolition

  • Cradle to grave, embodied Scope 3, category 5 382

Outside the scopes, reported separately

  • D −81.5

A1-A3 to A5, B1 to B3, B5, B7 and C1 to C4 are not declared: nothing to report.

CiteAPI

The factor, standardised

Every factor on open-climate.ai answers the same questions in the same words, whatever the publisher. Open any ⓘ for the definition.

Manufactured goods › Machinery · Ireland · per item · Supplier-specific

Cradle to grave · Fossil only · AR5

Boundary
Cradle to grave
Raw materials, inbound transport, fuel supply, fuel combustion, manufacturing, packaging, purchased energy, installation, outbound transport, use, maintenance and end of life
GWP method
IPCC AR5, 100-year horizon
Not on the record; set from EPD Ireland's method notes · impact method EF 3.0
CO₂e basis
Fossil only
Split by carbon origin, not by gas
Life cycle
Upstream: coveredProduction: coveredDownstream: coveredEnd of life: covered

High quality · Open licence · Any year

Module by module, up to the total

Seventeen EN 15804 modules, always in the same order. Each declared one moves the running total. D sits below zero after the total, because it is reported beside it.

kgCO₂e per unit. Each bar starts where the one before ended. Pick a module to read it.
Product
Con­struc­tion
Use
B1 to B3not de­clared
B5not de­clared
B7not de­clared
End of life
C1not de­clared
Beyond the boundary

beside the total, not in it

What this number covers

Follow 1 unit of this product through EN 15804's stages. The total counts what the EPD declares; what it leaves out stays visible.

  1. A1-A3Product

    Materials and making the product

    Included77.1
  2. A4-A5Construction

    Delivery and installation

    Included301
  3. B1-B7Use

    The product in service: maintenance, repair, replacement and the energy and water it uses; B1 to B3, B5, B7 not declared

    B4, B6911
  4. C1-C4End of life

    Waste transport to disposal; C1 not declared

    C2 to C44.23
  5. DBeyond the boundary

    Recovery after end of life

    Not in the total−81.5

Outside this boundary

  • Retail
  • Recycling credit

The recycling credit is module D, shown beside the total.

Gases

  • Fossil CO₂e1,293
  • Biogenic CO₂e14.2
  • Land-use CO₂e1.42

The total counts fossil CO₂e. EPD Ireland reports biogenic and land-use CO₂e separately; they are shown beside it, not added.

From EPD Ireland's record to a comparable factor

EPD Ireland publishes this EPD with one value per module. Each field as printed, and what open-climate.ai made of it.

The total and its modules

Use a module on its own when you report it in a different year or scope; never add one to the total.

You are here · the EPD total1,293
D beside−81.5
The three modules add up to the total; D stays beside it. Each opens its own page.

About this factor

From EPD Ireland

What it is

The dataset is representative for the production processes used in 2021. The data Quality Level, according to Table E.1 of EN 15804:2012+A2:2019, Annex E, is as follows: • Geographical representativeness: Very Good • Technical representativeness: Good • Time representativeness: Very Good Allocation of energy and electricity types and amounts to the various manufacturing processes has been provided by the manufacturers along with production waste. Allocation of impacts to the products is based on the product composition mass. Flows related to human activities such as employee transport are excluded. The construction of capital assets such as buildings, manufacture of machines and transportation systems are also excluded since the related flows are assumed to be negligible compared to the manufacture of the building material when compared to these systems over a full lifetime of operation. The dataset is representative for the production processes used in 2021. The data Quality Level, according to Table E.1 of EN 15804:2012+A2:2019, Annex E, is as follows: • Geographical representativeness: Very Good • Technical representativeness: Good • Time representativeness: Very Good

What it includes

Full technical details on these products can be found at: https://www.proair.ie/products/proair-frpro/

Where it applies

The ProAir FRPRO1 or ProAir FRPRO2 Mechanical Extract Ventilation (MEV) system provides continuous extract ventilation of stale and moisture laden air from damp rooms to a central extract fan via a system of ductwork. The extracted air is then normally discharged outside via a single vent. Replacement air is provided via ventilation openings in the living/bedroom walls. MEV systems help provide good indoor air quality, protecting the home from condensation, damp and mould. The unit is mounted in the attic/ loft or in a cupboard and ducted to extract polluted air from the damp rooms of the house. Main features: • Mechanical Extract Ventilation Unit (MEV) is suitable for residential and small commercial up to 150 m² • The ProAir MEV unit is unique because a filter is built into it. This protects the fan, keeps it working efficiently and extends the lifetime of the unit. The body of the unit is polyethylene • Fan: 190mm backward curved impellers, 163W power rated • MEV body: sound-absorbent dense polyurethane enclosure with metal coverings • Filter: 2no G4 Pleated panel • Max Airflow: 637 m3/hr @ 100 Pa The main materials used in the ProAir FRPRO1 and ProAir FRPRO2 are: Material: PE foam sheet kg per FU: 1 - 2 Post consumer recycled material (%): 0 Pre-consumer recycled material (%): 0 Material: Silicone sealant kg per FU: 0.2 - 0.4 Post consumer recycled material (%): 0 Pre-consumer recycled material (%): 0 Material: Hydrocarbon sealant kg per FU: 0.1 - 0.5 Post consumer recycled material (%): 0 Pre-consumer recycled material (%): 0 Material: Galvanised steel kg per FU: 5 - 7 Post consumer recycled material (%): 0 Pre-consumer recycled material (%): 0 Material: Electric motor kg per FU: 0.5 - 1.8 Post consumer recycled material (%): 0 Pre-consumer recycled material (%): 0 Material: PVC fixing kg per FU: 0.2 - 0.4 Post consumer recycled material (%): 0 Pre-consumer recycled material (%): 0 Material: Cardboard kg per FU: 0.05 - 0.2 Post consumer recycled material (%): 0 Pre-consumer recycled material (%): 0 Material: PP fibre kg per FU: 0.05 - 0.2 Post consumer recycled material (%): 0 Pre-consumer recycled material (%): 0 Material: PCB kg per FU: 0.01 - 0.04 Post consumer recycled material (%): 0 Pre-consumer recycled material (%): 0 Material: Packaging kg per FU: 0 Post consumer recycled material (%): 0 Pre-consumer recycled material (%): 0 The units are delivered to site in company vans. No product packaging is used. Component parts are assembled manually on an assembly line. The raw materials of the constituent components mostly comprise: PE, PVC, PP (fibre), neoprene, aluminium, mild steel, galvanised steel, copper, silicone & hydrocarbon sealants and printed circuit boards. Electricity is used for lighting, heating and power for power tools.

Source and licence

Value
Summed by open-climate.ai from its parts
Publisher
EPD Ireland (Irish Green Building Council)
Published
2 October 2026
Valid until
31 December 2027
See the source data at EPD Ireland

The values and their metadata are served in full and may be reused with credit to the publisher.

Credit it with this lineEPD Ireland (Irish Green Building Council), EPD data from https://epdireland.lca-data.com
A plain reading of the licence, not legal advice. The licence text prevails.

Cite this factor

EPD Ireland (Irish Green Building Council), EPD data from https://epdireland.lca-data.com. Normalised by open-climate.ai, https://open-climate.ai/factors/libraries/epd_ireland/ (CC BY 4.0). https://open-climate.ai/factors/ef-epdireland-proair_mechanical-ie-unit-cradle_to_grave-4f2c5f62/?v=efv1-65bfdc8379cc8b929c1cdbb373272bbb

Something looks wrong?

Tell us which value and why. We check it against the source and answer within a week.