Emission factor from GIR 2025

B-B fuel oil

Korea · Well-to-use · 2021 onwards

Each kilowatt-hour of this fuel from 2021 counts as 0.337 kg CO₂e: 0.276 from burning it and 0.0608 for producing it and bringing it to you (estimated).

Value per kWh, net calorific value

0.337kgCO₂e/kWh

Net calorific value · Biogenic CO₂ and land use excluded · GWP100 · AR5

FossilBio CH₄Land useBio CO₂GHG Protocol and IPCC inventories
2021–
Default: the latest year+2% on 2013–2020

Estimated Summed by open-climate.ai from 2 parts, 1 of them estimated by us

Region
Korea KR
Boundary
Well-to-use
Data quality
MediumRated by us, not by the source
Licence
Open · GIR terms

Where 0.337 comes from

  • Scope 10.27681.9%
  • Fuel supplyEstimatedDerived by open-climate.ai
    3.3 Energy upstream0.060818.1%
Derived by open-climate.ai

Σ 0.337: open-climate.ai adds up the two parts. GIR prints fuel combustion. open-climate.ai estimates fuel supply from other published figures.

Reporting this kilowatt-hour under the GHG Protocol

Scope 1 0.276 3.3 Energy upstream 0.0608

You burn the fuel, so its combustion is your Scope 1.

Supplying the fuel is Scope 3, category 3 for whoever burns it.

CiteAPI

The factor, standardised

Every factor on open-climate.ai answers the same questions in the same words, whatever the publisher. Open any ⓘ for the definition.

Fuels › Liquid fossil fuels · Korea · per kWh · Average

Well-to-use · Excl. biogenic CO₂ · AR5

Boundary
Well-to-use
Fuel supply and fuel combustion
GWP method
IPCC AR5, 100-year horizon
Not on the record; set from GIR's method notes
CO₂e basis
Excl. biogenic CO₂FossilBio CH₄Land useBio CO₂GHG Protocol and IPCC inventories
Not split by gas; CO₂e only

Medium quality · Open licence · 2012 to now

All values

3 values, one per period back to 2012. Every one is biogenic CO₂ and land use excluded, AR5 GWP100, so the years compare directly. Tap a bar.

2021 onwards0.337Default valueDerived by open-climate.ai

kgCO₂e per kWh, by year, split into its 2 parts. Pick a year to read it.

What this number covers

The path of one kilowatt-hour of this fuel, from the well to your flame. GIR gives one figure for the first three steps together.

  1. Well-to-tank0.06083.3 Energy upstream

    1. Extraction

      Getting the fuel out of the ground

    2. Processing

      Treating it to the quality it is sold at

    3. Transport

      Moving it to your site

  2. Your meter

    1 kWh used. The factor is per kWh measured here.

  3. Burning it

    In your boiler, furnace or engine: CO₂, with a little CH₄ and N₂O

    Scope 10.276

0.0608 + 0.276 = 0.337 per kWh

Outside this boundary

  • Making the boiler that burns it
  • Building the pipelines and the network

GIR counts the fuel, not the things built to extract, move and burn it.

Gases

GIR publishes this factor as CO₂e only, with no split by gas. The CO₂e leaves biogenic CO₂ and land-use carbon out; methane from biogenic sources is counted.

From GIR's record to a comparable factor

GIR publishes one of the two parts; open-climate.ai estimated the others and added them all up to this total. Here is each field as printed and what open-climate.ai made of it.

The total and its parts

Each part has its own page. Use a part on its own when you report Scope 1 and Scope 3 separately; never add a part to the total.

You are here · the totalB-B fuel oil, well-to-use0.337

About this factor

Source and licence

Value
Summed by open-climate.ai from its parts
Publisher
온실가스종합정보센터 (GIR, Greenhouse Gas Inventory and Research Center of Korea)
Library
GIR 2025
Published
18 December 2025
See the source data at GIR

The values and their metadata are served in full and may be reused with credit to the publisher.

Credit it with this line온실가스종합정보센터 (GIR), 승인 국가 온실가스 배출·흡수계수 (2012-2025)
A plain reading of the licence, not legal advice. The licence text prevails.

Cite this factor

온실가스종합정보센터 (GIR), 승인 국가 온실가스 배출·흡수계수 (2012-2025). Normalised by open-climate.ai, https://open-climate.ai/factors/libraries/gir_korea/ (CC BY 4.0). https://open-climate.ai/factors/ef-girkorea-bb-kr-kwh-well_to_use-7c897868/?v=efv1-21104256a8968a5b567db98e26e5bceb

Something looks wrong?

Tell us which value and why. We check it against the source and answer within a week.

Page data as of .