Emission factor from NGA 2026

Grid electricity - Network operator (transmission and distribution)

South Australia · Upstream fuel · Any year

Each kilowatt-hour drawn from the grid counts as 0.01 kg CO₂e for the fuel supplied to the power plants. NGA gives one figure, for use in any year.

Value for any year

0.01kgCO₂e/kWh

Biogenic CO₂ and land use excluded · GWP100 · AR5

FossilBio CH₄Land useBio CO₂GHG Protocol and IPCC inventories

One value, for any year

NGA sets no date window, so there is no year to pick.

Reference year 2025

Region
South Australia AU-SA
Boundary
Upstream fuel
Data quality
HighRated by us, not by the source
Licence
Open · CC BY 4.0

Where 0.01 comes from

Published as one number

NGA prints this factor as a single figure, with no parts to add up and no split by gas.

Reporting this kilowatt-hour under the GHG Protocol

3.3 Energy upstream 0.01

Extracting, refining and delivering the fuel behind it happens upstream: Scope 3, category 3.

CiteAPI

The factor, standardised

Every factor on open-climate.ai answers the same questions in the same words, whatever the publisher. Open any ⓘ for the definition.

Electricity › Electricity distribution and trade · South Australia · per kWh · Average

Upstream fuel · Excl. biogenic CO₂ · AR5

Boundary
Upstream fuel
Fuel supply
GWP method
IPCC AR5, 100-year horizon
Not on the record; inferred by open-climate.ai
CO₂e basis
Excl. biogenic CO₂FossilBio CH₄Land useBio CO₂GHG Protocol and IPCC inventories
Not split by gas; CO₂e only
Life cycle
Upstream: partly coveredProduction: not coveredDownstream: not applicableEnd of life: not applicable

High quality · Open licence · Any year

What this number covers

The path of one kilowatt-hour, from the fuel to your meter. Not every step on it is counted; what is left out is listed below.

  1. Fuel supply

    Extracting, processing and transporting the fuel the plants burn

    Included0.01
  2. Your meter

    1 kWh used. The factor is per kWh measured here.

    = 0.01

Outside this boundary

  • Electricity lost on the network
  • Burning fuel at the plants
  • Purchased electricity and heat
  • Building the power plants
  • Building the grid

NGA counts running the plants, not building them.

From NGA's record to a comparable factor

NGA publishes this factor as one record. Here is each field as printed and what open-climate.ai made of it.

About this factor

From NGA

Where it applies

Scope 3 emissions for transmission and distribution network operators exclude emissions from electricity losses in the grid. They include only emissions tied to the extraction, production and transport of fuels that power the grid.

Source and licence

Publisher
Department of Climate Change, Energy, the Environment and Water (DCCEEW)
Library
NGA 2026
Record
t25 · table number
Open the record at NGA

The values and their metadata are served in full and may be reused with credit to the publisher.

Credit it with this lineDCCEEW 2026, Australian National Greenhouse Accounts Factors, Department of Climate Change, Energy, the Environment and Water, Canberra, September. CC BY 4.0.
A plain reading of the licence, not legal advice. The licence text prevails.

Cite this factor

DCCEEW 2026, Australian National Greenhouse Accounts Factors, Department of Climate Change, Energy, the Environment and Water, Canberra, September. CC BY 4.0. Normalised by open-climate.ai, https://open-climate.ai/factors/libraries/nga_australia/ (CC BY 4.0). https://open-climate.ai/factors/ef-ngaaustralia-grid_electricity_network-au_sa-kwh-upstream_fuel-52ac6ef3/?v=efv1-a77d8766f6b204404533831dc5ea4848

Something looks wrong?

Tell us which value and why. We check it against the source and answer within a week.

Page data as of .