Emission factor from Norsk Fjernvarme
District heating - Stjørdal (Lunera Energi)
Norway · Well-to-use · 2025 onwards
Value from 2025 onwards
0.0127kgCO₂e/kWh
Biogenic CO₂ and land use excluded · GWP100 · GWP vintage not stated
FossilBio CH₄Land useBio CO₂GHG Protocol and IPCC inventories- Region
- Norway NO
- Boundary
- Well-to-use
- Data quality
- MediumRated by us, not by the source
- Licence
- Open · Norsk Fjernvarme terms
Where 0.0127 comes from
Norsk Fjernvarme prints this factor as a single figure, with no parts to add up and no split by gas.
Reporting this kilowatt-hour under the GHG Protocol
Scope 2 + 3.3 Energy upstream 0.0127
This one figure covers both together; no split between them is given.
You buy the energy, so its generation is your Scope 2.
The fuel behind it and the energy lost on the way to you are Scope 3, category 3.
The factor, standardised
Every factor on open-climate.ai answers the same questions in the same words, whatever the publisher. Open any ⓘ for the definition.
Heat and cooling › District heat and steam · Norway · per kWh · Average
Well-to-use · Excl. biogenic CO₂
- BoundaryWell-to-useOne unit of energy as consumed, priced from the well to the point of use: the well-to-tank chain plus the burn for a fuel; generation, its well-to-tank and the transmission and distribution losses for a delivered carrier (electricity, steam or hot water, chilled water). Learn more
- Well-to-use
- Fuel supply, generation and network losses
- GWP methodWhich IPCC assessment report's warming potentials convert each gas to CO₂e, and over how many years the warming is counted (GWP100: 100 years). Learn more
- Not stated by the publisher
- CO₂e basisWhich carbon the CO₂e counts. Fossil only leaves out biogenic methane, land-use change and biogenic CO₂; excl. biogenic CO₂ counts biogenic methane but not the other two; net total counts every pool, net of removals. The same activity on two bases is two different numbers. Learn more
- Excl. biogenic CO₂FossilBio CH₄Land useBio CO₂GHG Protocol and IPCC inventories
- Not split by gas; CO₂e only
Medium quality · Open licence · 2022 to now
All values
4 values, one per year back to 2022. Every one is biogenic CO₂ and land use excluded, GWP not stated by the publisher, so the years compare directly. Tap a bar.
2025 onwards0.0127Default value
What this number covers
The path of one kilowatt-hour of heat, from the fuel to your meter. Every step on it is counted.
Fuel supply
Extracting, processing and transporting the fuel the heat plants burn
Included, not split outHeat generation
Producing the heat and steam at the plants that feed the network
Included, not split outNetwork losses
Heat lost in the pipes between the plant and your meter, which still had to be produced
Included, not split outYour meter
1 kWh used. The factor is per kWh measured here.
= 0.0127
Outside this boundary
- Building the heat plants
- Building the heat network
Capital goods and infrastructure sit outside every well-to-use factor, in every library.
From Norsk Fjernvarme's record to a comparable factor
Norsk Fjernvarme publishes this factor as one record. Here is each field as printed and what open-climate.ai made of it.
About this factor
Norsk Fjernvarme gives no description for this factor. Filed under Electricity, gas, steam and air conditioning supply.
Source and licence
- Publisher
- Norsk Fjernvarme
- Library
- Norsk Fjernvarme
- Record
- 50
- Published
- 9 November 2026
The values and their metadata are served in full and may be reused with credit to the publisher.
Changes: values computed as the calculator's total for 1,000 kWh delivered divided by 1,000 and converted from g to kg; the European-mix figure stored beside the Norwegian one. Norsk Fjernvarme does not endorse this use.
Cite this factor
Kilde: Norsk Fjernvarme, fjernkontrollen.no, klimaregnskap per fjernvarmeanlegg, hentet 2026-11-09. https://www.fjernkontrollen.no/. Normalised by open-climate.ai, https://open-climate.ai/factors/libraries/norsk_fjernvarme/ (CC BY 4.0). https://open-climate.ai/factors/ef-norskfjernvarme-fjernvarme_stjrdal-no-kwh-well_to_use-0c7b6ce3/?v=efv1-f69417c488736dc9d18eba6d3bcbce63
Something looks wrong?
Tell us which value and why. We check it against the source and answer within a week.
Page data as of .