Emission factor from ÖKOBAUDAT OBD_2024_III EPD, product-specific
MAGNA3 50-40/ 60/ 80/ 100/ 120 F (Stainless Steel) and MAGNA3 32-120 F (Stainless Steel)
Germany · EPD total · Reference year 2024
Each unit of this product counts as 229 kg CO₂e over the modules its EPD declares: 108 in use (B6) and 121 for cradle to grave, embodied.
Value per unit, module B6 only
229kgCO₂e/unit
EN 15804 module B6 · Fossil only · GWP100 · AR5
FossilBio CH₄Land useBio CO₂EN 15804 GWP-fossilDerived by open-climate.ai: the sum of ÖKOBAUDAT's published parts
The one scenario this EPD declaresReference year 2024
- Region
- Germany DE
- Boundary
- EPD total
- Data quality
- HighRated by us, not by the source
- Licence
- Open · ÖKOBAUDAT terms
- Declared by
- Grundfos Holding A/S
Where 229 comes from
- Cradle to grave, embodiedDerived by open-climate.aiScope 3, cat. 2, 4 and 512152.9%
- Scope 1 Scope 2 3.3 Energy upstream10847.1%
- Outside−8.57beside
Σ 229: the two declared modules add up to the total. D stays beside it.
Reporting this item under the GHG Protocol
This period
Scope 3, categories 2 and 4 121
This one figure covers both together; no split between them is given.
The product becomes part of a building you own. The product and its installation go to category 2 in the year you buy it, the delivery to category 4. Use and end of life are reported in the years they happen.
Later, when it happens
During use, in the years the building stands
- B6 Scope 1 Scope 2 3.3 Energy upstream 108
At end of life, in the year of demolition
- Cradle to grave, embodied 3.5 Waste 121
Outside the scopes, reported separately
- D −8.57
A1-A3 to A5, B1 to B5, B7 and C1 to C4 are not declared: nothing to report.
The factor, standardised
Every factor on open-climate.ai answers the same questions in the same words, whatever the publisher. Open any ⓘ for the definition.
Manufactured goods › Machinery · Germany · per item · Supplier-specific
EPD total · Fossil only · AR5
- BoundaryEPD totalThe sum of every EN 15804 module an EPD declares, when that set is not the complete A-C grid (MOD-0034). Learn more
- EPD total
- Raw materials, inbound transport, fuel supply, fuel combustion, manufacturing, packaging, purchased energy, installation, outbound transport, use, maintenance and end of life
- GWP methodWhich IPCC assessment report's warming potentials convert each gas to CO₂e, and over how many years the warming is counted (GWP100: 100 years). Learn more
- IPCC AR5, 100-year horizon
- Not on the record; set from ÖKOBAUDAT's method notes · impact method EF 3.0
- CO₂e basisWhich carbon the CO₂e counts. Fossil only leaves out biogenic methane, land-use change and biogenic CO₂; excl. biogenic CO₂ counts biogenic methane but not the other two; net total counts every pool, net of removals. The same activity on two bases is two different numbers. Learn more
- Fossil onlyFossilBio CH₄Land useBio CO₂EN 15804 GWP-fossil
- Split by carbon origin, not by gas
- Life cycle
- Upstream: coveredProduction: coveredDownstream: partly coveredEnd of life: partly covered
High quality · Open licence · Any year
Module by module, up to the total
Seventeen EN 15804 modules, always in the same order. Each declared one moves the running total. D sits below zero after the total, because it is reported beside it.
beside the total, not in it
| Module | Name | Per unit | Running total | Status |
|---|---|---|---|---|
| A1 | Raw material supply | 105 | 105 | Declared |
| A2 | Transport to the plant | 4.69 | 109.69 | Declared |
| A3 | Manufacturing | 3.6 | 113.29 | Declared |
| A4 | Transport to site | 1.58 | 114.87 | Declared |
| A5 | Installation | 0.111 | 114.981 | Declared |
| B1 | Use | not declared | 114.981 | Not declared |
| B2 | Maintenance | not declared | 114.981 | Not declared |
| B3 | Repair | not declared | 114.981 | Not declared |
| B4 | Replacement | not declared | 114.981 | Not declared |
| B5 | Refurbishment | not declared | 114.981 | Not declared |
| B6 | Energy in use | 108 | 222.981 | Declared |
| B7 | Water in use | not declared | 222.981 | Not declared |
| C1 | Demolition | not declared | 222.981 | Not declared |
| C2 | Waste transport | 0.645 | 223.626 | Declared |
| C3 | Waste processing | 5.72 | 229.346 | Declared |
| C4 | Disposal | 0.121 | 229.467 | Declared |
| Total | EPD total, declared modules | 229.467 | Sum of the declared modules | |
| D | Beyond the system boundary | −8.57 | not added | Beside the total, not in it |
What this number covers
Follow 1 unit of this product through EN 15804's stages. The total counts what the EPD declares; what it leaves out stays visible.
A1-A3Product
Materials and making the product
Included113A4-A5Construction
Delivery and installation
Included1.69B1-B7Use
Energy in use only; B1 to B5, B7 not declared
B6 only108C1-C4End of life
Waste transport to disposal; C1 not declared
C2 to C46.49DBeyond the boundary
Recovery after end of life
Not in the total−8.57
Outside this boundary
- Retail
- Recycling credit
The recycling credit is module D, shown beside the total.
Gases
- Fossil CO₂e229
- Biogenic CO₂e0.553
- Land-use CO₂e0.133
The total counts fossil CO₂e. ÖKOBAUDAT reports biogenic and land-use CO₂e separately; they are shown beside it, not added.
From ÖKOBAUDAT's record to a comparable factor
ÖKOBAUDAT publishes this EPD as one declared value. Each field as printed, and what open-climate.ai made of it.
The total and its modules
Use a module on its own when you report it in a different year or scope; never add one to the total.
About this factor
From ÖKOBAUDAT
What it is
The Grundfos MAGNA3 circulator pumps are designed for circulating liquids in heating systems, air conditioning and cooling systems and domestic hot water systems. However, the pump range can also be used in ground source heat pump systems and solar heating systems. The MAGNA3 pump is a centrifugal pump powered by an electrical motor. It has a high-performance neodymium magnet rotor which increases motor efficiency and an insulation shell to reduce heat loss from the cast iron pump housing with threaded connections. The declaration covers six types of the MAGNA3 pump. They are listed below. The group reference in the technical data and scenarios refers also to these. MAGNA3 50-40 F (Group 1) MAGNA3 50-60 F (Group 2) MAGNA3 50-80 F (Group 3) MAGNA3 50-100 F (Group 4) MAGNA3 50-120 F (Group 5) MAGNA3 32-120 F (Group 6) The MAGNA 3 50-40/60/80/100/120 F are all the same physical products and 100 % identical in terms of design, dimensions and materials as well as supply chain and manufacturing processes, i.e., all cradle to gate processes (A1-A3).The MAGNA 3 32-120 flanged version (F), although smaller, utilizes the same technology and materials as the MAGNA 3 50-40/60/80/100/120 F. Given its smaller size, it is expected to have a lower environmental impact in A1-A3, but the MAGNA 3 50-40/60/80/100/120 F results will cover it being the 'worst-case' scenario EPD of the MAGNA3 32-120 F. The justification is the reduced material usage and the lower energy consumption during operation. The technical specifications table is separate for the 32-120 F, which clearly proves the justification. The B6 factor will also be indicated. The products are also identical in terms of packaging, distribution, reference service life and end-of-life treatment. The only thing that differentiates the products from each other is the software which controls how the pump operates in the system in which it is installed, making them fit for different applications. Hence, all life cycle modules are identical, except use stage module B6, which will change, as the applied scenarios for electricity consumption changes.What it includes
The Grundfos MAGNA3 circulation pumps are designed for circulating liquids in heating systems, air conditioning and cooling systems and domestic hot water systems. However, the pump series can also be used in geothermal heat pump systems and solar systems. Technical data: The performance data of the product according to the harmonised norms, based on the harmonisation provisions above apply. The relevant technical specifications according to the PCR Part B are given in the table below. Characteristics that are the same for all three product groups are only given once. Others are given individually for all three groups. Declared unit: The declared unit is 1 piece (pcs.) of MAGNA3 Stainless Steel pump.Where it applies
For the application and use the respective national provisions apply. The pump is designed for circulating liquids in the following systems: · heating systems · domestic hot-water systems · air-conditioning and cooling systems · ground-source heat-pump systems · solar-heating systems The pump is suitable for thin, clean, non-aggressive and non-explosive liquids, not containing solid particles or fibres that may attack the pump mechanically or chemically. In heating systems, the water must meet the requirements of accepted standards on water quality. The pumps are also suitable for domestic hot-water systems.Source and licence
- Value
- Summed by open-climate.ai from its parts
- Publisher
- ÖKOBAUDAT (BBSR / BMWSB)
- Library
- ÖKOBAUDAT OBD_2024_III
- Published
- 13 November 2026
- Valid until
- 31 December 2029
The values and their metadata are served in full and may be reused with credit to the publisher.
Cite this factor
Source: ÖKOBAUDAT (OBD_2024_III), BBSR / BMWSB. Individual EPDs © their respective programme operators / declaration owners. Normalised by open-climate.ai, https://open-climate.ai/factors/libraries/okobaudat/ (CC BY 4.0). https://open-climate.ai/factors/ef-okobaudat-magna3_50406080100120_f-de-unit-epd_total-9e72ea26/?v=efv1-29466fab7d5969047bb9169f3d8498d3
Something looks wrong?
Tell us which value and why. We check it against the source and answer within a week.
Page data as of .