Emission factor from ÖKOBAUDAT OBD_2024_III Generic data

Refrigerant R410a

Germany · EPD total · Any year

Each kilogram counts as 2,492 kg CO₂e: 10.6 up to the factory gate and 2,481 for use.

Value per kilogram, over the modules the dataset declares

2,492kgCO₂e/kg

EN 15804 modules A1 to B1 · Fossil only · GWP100 · AR6

FossilBio CH₄Land useBio CO₂EN 15804 GWP-fossil

Derived by open-climate.ai: the sum of ÖKOBAUDAT's published parts

The one scenario this EPD declaresReference year 2023

Region
Germany DE
Boundary
EPD total
Data quality
MediumRated by us, not by the source
Licence
Open · ÖKOBAUDAT terms

Where 2,492 comes from

Derived by open-climate.ai

Σ 2,492: the two declared modules add up to the total. D stays beside it.

Reporting this kilogram under the GHG Protocol

This period

3.1 Goods we buy 10.6

You buy the product for a building that is not yours. The product and its installation go to category 1, the delivery to category 4. The use stage belongs to the building owner; demolition waste you handle is category 5.

Later, when it happens

During use: the building owner reports it

  • B1 Not yours to report 2,481

Outside the scopes, reported separately

  • D −8.79

A4, A5, B2 to B7 and C1 to C4 are not declared: nothing to report.

CiteAPI

The factor, standardised

Every factor on open-climate.ai answers the same questions in the same words, whatever the publisher. Open any ⓘ for the definition.

Materials › Chemicals · Germany · per kg · Generic

EPD total · Fossil only · AR6

Boundary
EPD total
Raw materials, inbound transport, fuel supply, fuel combustion, manufacturing, packaging, purchased energy and use
GWP method
IPCC AR6, 100-year horizon
Not on the record; set from ÖKOBAUDAT's method notes · impact method EF 3.1
CO₂e basis
Fossil onlyFossilBio CH₄Land useBio CO₂EN 15804 GWP-fossil
Split by carbon origin, not by gas
Life cycle
Upstream: coveredProduction: coveredDownstream: partly coveredEnd of life: partly covered

Medium quality · Open licence · Any year

Module by module, up to the total

Seventeen EN 15804 modules, always in the same order. Each declared one moves the running total. D sits below zero after the total, because it is reported beside it.

kgCO₂e per kilogram. Each bar starts where the one before ended. Pick a module to read it.
Product
Con­struc­tion
A4 to A5not de­clared
Use
B2 to B7not de­clared
End of life
C1 to C4not de­clared
Beyond the boundary

beside the total, not in it

What this number covers

Follow one kilogram of this product through EN 15804's stages. The total counts what the EPD declares; what it leaves out stays visible.

  1. A1-A3Product

    Materials and making the product

    Included10.6
  2. A4-A5Construction

    Delivery and installation

    Not declared
  3. B1-B7Use

    Use only; B2 to B7 not declared

    B1 only2,481
  4. C1-C4End of life

    From demolition to disposal

    Not declared
  5. DBeyond the boundary

    Recovery after end of life

    Not in the total−8.79

Outside this boundary

  • Installation
  • Maintenance
  • Outbound transport
  • Retail
  • End of life
  • Recycling credit

Maintenance is out because B2 is not declared. The recycling credit is module D, shown beside the total.

Gases

  • Fossil CO₂e2,492
  • Biogenic CO₂e0.0558
  • Land-use CO₂e0.00324

The total counts fossil CO₂e. ÖKOBAUDAT reports biogenic and land-use CO₂e separately; they are shown beside it, not added.

From ÖKOBAUDAT's record to a comparable factor

ÖKOBAUDAT publishes this EPD with one value per module. Each field as printed, and what open-climate.ai made of it.

The total and its modules

Use a module on its own when you report it in a different year or scope; never add one to the total.

You are here · the EPD total2,492
D beside−8.79
The two modules add up to the total; D stays beside it. Each opens its own page.

About this factor

From ÖKOBAUDAT

What it is

This data set has been modeled according to the European Standard EN 15804+A2 for Sustainable Building. Results are depicted in modules that allow the structured expression of results over the entire life cycle.

What it includes

The manufacturing (modules A1-A3) of the refrigerant is carried out by mixing the two refrigerants R32 and R125 (50/50). The upstream chain of the above mentioned basic chemicals dominates the manufacturing phase (modules A1-A3). In module B1, the escape of 1 kg of refrigerant into the air was accounted for. The values of module B1 can be used for both the usage phase (e.g., leakage) and the disposal phase (module C1 disposal losses). Scenarios for use and disposal must be defined at the building level (see field "Use advice for data set"). In the disposal phase (C-modules), any burdens due to removal (usually extraction by means of compressed air in special container systems), transport to the disposal or recycling company, as well as the loads for chemical analysis (e.g. gas chromatography) were neglected. Disposal losses (emissions into the air) must be determined at building level (see above). In module D, 100% material recycling was accounted for. If properly extracted, the refrigerant can be reused directly (without treatment) with the appropriate purity.

Where it applies

The usual purpose is the use in air conditioners and heat pumps.

Source and licence

Value
Summed by open-climate.ai from its parts
Publisher
ÖKOBAUDAT (BBSR / BMWSB)
Published
13 November 2026
Valid until
31 December 2026
See the source data at ÖKOBAUDAT

The values and their metadata are served in full and may be reused with credit to the publisher.

Credit it with this lineSource: ÖKOBAUDAT (OBD_2024_III), BBSR / BMWSB. Individual EPDs © their respective programme operators / declaration owners.
A plain reading of the licence, not legal advice. The licence text prevails.

Cite this factor

Source: ÖKOBAUDAT (OBD_2024_III), BBSR / BMWSB. Individual EPDs © their respective programme operators / declaration owners. Normalised by open-climate.ai, https://open-climate.ai/factors/libraries/okobaudat/ (CC BY 4.0). https://open-climate.ai/factors/ef-okobaudat-refrigerant_r410a-de-kg-epd_total-4325cd27/?v=efv1-952c60712505b6adaf3f818258f05513

Something looks wrong?

Tell us which value and why. We check it against the source and answer within a week.

Page data as of .