Emission factor from ÖKOBAUDAT OBD_2024_III EPD, industry average
TEC2 T-TE 2500-9 BK
European Union (27) · Cradle to grave, embodied · Reference year 2026
Value per unit, over the modules the EPD declares
14.5kgCO₂e/unit
EN 15804 modules A1 to A5 · Fossil only · GWP100 · AR5
FossilBio CH₄Land useBio CO₂EN 15804 GWP-fossilDerived by open-climate.ai: the sum of ÖKOBAUDAT's published parts
The one scenario this EPD declaresReference year 2026
- Region
- European Union (27)
- Boundary
- Cradle to grave, embodied
- Data quality
- MediumRated by us, not by the source
- Licence
- Open · ÖKOBAUDAT terms
- Declared by
- Zumtobel Lighting GmbH
Where 14.5 comes from
- A1-A3 Product stage3.1 Goods we buy11.780.8%
- 3.4 Freight we pay0.2141.5%
- A5 Installation3.1 Goods we buy0.1591.1%
- End of lifeDerived by open-climate.ai3.5 Waste2.4216.7%
- Outside−7.46beside
Σ 14.5: the four declared modules add up to the total. D stays beside it.
Reporting this item under the GHG Protocol
This period
3.1 Goods we buy 11.9 3.4 Freight we pay 0.214
You buy the product for a building that is not yours. The product and its installation go to category 1, the delivery to category 4. The use stage belongs to the building owner; demolition waste you handle is category 5.
Later, when it happens
At end of life, in the year of demolition
- End of life 3.5 Waste 2.42
Outside the scopes, reported separately
- D −7.46
B1 to B7 and C1 to C4 are not declared: nothing to report.
The factor, standardised
Every factor on open-climate.ai answers the same questions in the same words, whatever the publisher. Open any ⓘ for the definition.
Manufactured goods › Electrical equipment · European Union (27) · per item · Average
Cradle to grave, embodied · Fossil only · AR5
- BoundaryCradle to grave, embodiedThe whole life cycle EXCEPT the use stage: cradle_to_gate plus distribution to site, installation and end-of-life (EN 15804 A1-A3 + A4 + A5 + C1-C4). Learn more
- Cradle to grave, embodied
- Raw materials, inbound transport, fuel supply, fuel combustion, manufacturing, packaging, purchased energy, installation, outbound transport and end of life
- GWP methodWhich IPCC assessment report's warming potentials convert each gas to CO₂e, and over how many years the warming is counted (GWP100: 100 years). Learn more
- IPCC AR5, 100-year horizon
- Not on the record; set from ÖKOBAUDAT's method notes · impact method EF 3.0
- CO₂e basisWhich carbon the CO₂e counts. Fossil only leaves out biogenic methane, land-use change and biogenic CO₂; excl. biogenic CO₂ counts biogenic methane but not the other two; net total counts every pool, net of removals. The same activity on two bases is two different numbers. Learn more
- Fossil onlyFossilBio CH₄Land useBio CO₂EN 15804 GWP-fossil
- Split by carbon origin, not by gas
- Life cycle
- Upstream: coveredProduction: coveredDownstream: partly coveredEnd of life: covered
Medium quality · Open licence · Any year
Module by module, up to the total
Seventeen EN 15804 modules, always in the same order. Each declared one moves the running total. D sits below zero after the total, because it is reported beside it.
beside the total, not in it
| Module | Name | Per unit | Running total | Status |
|---|---|---|---|---|
| A1-A3 | Product stage | 11.7018 | 11.7018 | Declared |
| A4 | Transport to site | 0.213839 | 11.9157 | Declared |
| A5 | Installation | 0.158591 | 12.0743 | Declared |
| B1 | Use | not declared | 12.0743 | Not declared |
| B2 | Maintenance | not declared | 12.0743 | Not declared |
| B3 | Repair | not declared | 12.0743 | Not declared |
| B4 | Replacement | not declared | 12.0743 | Not declared |
| B5 | Refurbishment | not declared | 12.0743 | Not declared |
| B6 | Energy in use | not declared | 12.0743 | Not declared |
| B7 | Water in use | not declared | 12.0743 | Not declared |
| C1 | Demolition | 0.0365243 | 12.1108 | Declared |
| C2 | Waste transport | 0.0305485 | 12.1413 | Declared |
| C3 | Waste processing | 2.34889 | 14.4902 | Declared |
| C4 | Disposal | 0.000422526 | 14.4907 | Declared |
| Total | EPD total, declared modules | 14.4907 | Sum of the declared modules | |
| D | Beyond the system boundary | −7.46037 | not added | Beside the total, not in it |
What this number covers
Follow 1 unit of this product through EN 15804's stages. The total counts what the EPD declares; what it leaves out stays visible.
A1-A3Product
Materials and making the product
Included11.7A4-A5Construction
Delivery and installation
Included0.372B1-B7Use
The product in service: maintenance, repair, replacement and the energy and water it uses
Not declaredC1-C4End of life
From demolition to disposal
Included2.42DBeyond the boundary
Recovery after end of life
Not in the total−7.46
Outside this boundary
- Maintenance
- Retail
- Use phase
- Recycling credit
Maintenance is out because B2 is not declared. The recycling credit is module D, shown beside the total.
Gases
- Fossil CO₂e14.5
- Biogenic CO₂e0.0279
- Land-use CO₂e0.0158
The total counts fossil CO₂e. ÖKOBAUDAT reports biogenic and land-use CO₂e separately; they are shown beside it, not added.
From ÖKOBAUDAT's record to a comparable factor
ÖKOBAUDAT publishes this EPD with one value per module. Each field as printed, and what open-climate.ai made of it.
The total and its modules
Use a module on its own when you report it in a different year or scope; never add one to the total.
About this factor
From ÖKOBAUDAT
What it is
This data set has been modeled according to the European Standard EN 15804+A2 for Sustainable Building. Results are depicted in modules that allow the structured expression of results over the entire life cycle. Transport modul: A Standard scenario with a truck with a transport distance of 700 km in Europe is considered. The weight of the transported unit includes product with packaging. Use-stage modul: During the use-stage, consumption of electricity is calculated, based on a for the declared product characteristical, standardardised scenario. All use-scenarios are defined in the [PCR part B] of IBU. Not only annual operating time, average product lifetime and power consumption is considered but also additional influences like stand-by circuits, dimming function and more. The following electricity grid mix is applied by default: EU Allocation of waste material: For the treatment of production residues the calculation considers the increased demand of materials' input resulting in production residues during manufacturing. These material flows are not connected to an EoL-scenario. Avoided burdens for secondary material in case of potential recycling are not included. End-of-life modul: As an EoL scenario the product as well as the replacement parts are assumed to be collected to 100% (legal requirements defined within WEEE directive). The product and replacement parts are fed to a generic shredding process with fixed demand on electrical energy per input mass (C3) of 1,2 MJ/kg, resulting in different waste fractions. For the amount of metal flows respective recycling processes are considered, including recycling losses. Environmental burdens of recycling processes, as well as avoided burdens for secondary materials are assigned as total value in module D. The plastic fraction is fed into a process for waste incineration (B4/C3). The calculation of emissions from the waste incineration plant follows a partial stream consideration for the combustion process, according to an average mix of plastics.What it includes
TECTON II continuous row for start of trunking made of roll-formed sheet steel with polyester coating in black. A total of 9 cores, 5 mains power lines (5 x 2.5mm²/16A) plus 2 x 2 cores (2 x 2.5mm²/16A) for integrating the emergency lighting via one independently insulated circuit, plus 1x2 control lines (2 x 1.5mm²/10A). Tool-free mechanical and electrical connection.. Dimensions: 2500 x 64 x 60 mm; weight: 4.15 kg The manufacturing process includes production technologies such as plastic injection moulding, plastics processing, metalworking and powder coating, as well as the operation of highly automated systems for assembling the products. All primary and secondary data are modelled to be specific to the technologies or technology mixes under study. Where technology-specific data are unavailable, proxy data are used. Technological representativeness is considered to be good.Where it applies
The declared product is a professional LED luminaire that is used for application 'Office'.Source and licence
- Value
- Summed by open-climate.ai from its parts
- Publisher
- ÖKOBAUDAT (BBSR / BMWSB)
- Library
- ÖKOBAUDAT OBD_2024_III
- Published
- 13 November 2026
- Valid until
- 31 December 2031
The values and their metadata are served in full and may be reused with credit to the publisher.
Cite this factor
Source: ÖKOBAUDAT (OBD_2024_III), BBSR / BMWSB. Individual EPDs © their respective programme operators / declaration owners. Normalised by open-climate.ai, https://open-climate.ai/factors/libraries/okobaudat/ (CC BY 4.0). https://open-climate.ai/factors/ef-okobaudat-tec2_tte_25009_bk-eu27-unit-cradle_to_grave_embodied-9d8931fa/?v=efv1-36ddaeb823cfb4db413f912591feb034
Something looks wrong?
Tell us which value and why. We check it against the source and answer within a week.
Page data as of .