Value from 2021 onwards
0.418kgCO₂e/kWh
Location-based · Consumption mix · Biogenic CO₂ and land use excluded · GWP100 · AR6
FossilBio CH₄Land useBio CO₂GHG Protocol and IPCC inventoriesGermany: every library's grid factor, side by side
- Region
- Germany DE
- Boundary
- Generation
- Data quality
- MediumRated by us, not by the source
- Licence
- Open · UBA (DE) terms
Where 0.418 comes from
UBA (DE) prints this factor as a single figure, with no parts to add up.
Reporting this kilowatt-hour under the GHG Protocol
Scope 2 0.418
You buy the energy, so its generation is your Scope 2.
The factor, standardised
Every factor on open-climate.ai answers the same questions in the same words, whatever the publisher. Open any ⓘ for the definition.
Electricity › Grid electricity · Germany · per kWh · Average
Generation · Location-based · Excl. biogenic CO₂ · AR6
- BoundaryGenerationCombustion at the generating plant for purchased energy carriers. Learn more
- Generation
- Calculation approachLocation-based uses the average grid mix where the electricity was consumed; market-based uses the supplier contract or the residual mix. The two can differ by an order of magnitude on the same kilowatt-hour, so they are never interchangeable. Learn more
- Location-based, consumption mix
- GWP methodWhich IPCC assessment report's warming potentials convert each gas to CO₂e, and over how many years the warming is counted (GWP100: 100 years). Learn more
- IPCC AR6, 100-year horizon
- Re-weighted by open-climate.ai from UBA (DE)'s AR5 figure of 0.418 kgCO₂e/kWh
- CO₂e basisWhich carbon the CO₂e counts. Fossil only leaves out biogenic methane, land-use change and biogenic CO₂; excl. biogenic CO₂ counts biogenic methane but not the other two; net total counts every pool, net of removals. The same activity on two bases is two different numbers. Learn more
- Excl. biogenic CO₂FossilBio CH₄Land useBio CO₂GHG Protocol and IPCC inventories
- Split by gas
- Life cycle
- Upstream: not coveredProduction: coveredDownstream: not applicableEnd of life: not applicable
Medium quality · Open licence · 1999 to now
All values
3 values, one per period back to 1999. Every one is location-based, consumption mix, biogenic CO₂ and land use excluded, AR6 GWP100, so the years compare directly. Tap a bar.
2021 onwards0.418Default value
| AppliesYears | TotalkgCO₂e/kWh |
|---|---|
| 0.418Default value | |
| 0.649 | |
| 0.77 |
- Default: what search and the API return when you ask for nothing specific
What this number covers
The path of one kilowatt-hour, from the fuel to your meter. Not every step on it is counted; what is left out is listed below.
Generation
Producing the electricity at the power plants that make up the mix
Included0.418Your meter
1 kWh used. The factor is per kWh measured here.
= 0.418
Outside this boundary
- Electricity lost on the network
- Producing and delivering the plants' fuel
- Building the power plants
UBA (DE) counts burning fuel at the plants, not producing and delivering that fuel or building the plants.
Gases
Basis: Excl. biogenic CO₂Biogenic CO₂ and land-use change are left out; fossil CO₂, the other greenhouse gases and methane from biogenic sources are counted. Learn moreFossilBio CH₄Land useBio CO₂GHG Protocol and IPCC inventories
- Fossil CO₂0.37589.6%
- Methane (CH₄)0.004881.2%
- Nitrous oxide (N₂O)0.003120.7%
- Rest, not split by gas Derived by open-climate.ai0.03578.5%
The rest is not split by gas: open-climate.ai works it out as the 0.418 total less the gases UBA (DE) prints.
Each gas is converted to CO₂e with AR6 100-year warming potentials; biogenic CO₂ and land-use carbon are left out, while methane from biogenic sources is counted.
From UBA (DE)'s record to a comparable factor
UBA (DE) publishes this factor as one German record. Here is each field as printed and what open-climate.ai made of it.
About this factor
UBA (DE) gives no description for this factor. Filed under Electricity, gas, steam and air conditioning supply.
Source and licence
- Publisher
- Umweltbundesamt (UBA)
- Library
- UBA (DE) Data year 2024
- Published
- 1 September 2025
The values and their metadata are served in full and may be reused with credit to the publisher.
Used with the written consent of the Umweltbundesamt (2026-11-09), on condition that the source is acknowledged. The consent is not § 12a EGovG open data: UBA does not count these factors as unprocessed raw data.
Cite this factor
Source: German Environment Agency (Umweltbundesamt), September 2025: Emissionsbilanz erneuerbarer Energieträger, unter Verwendung von Daten der AGEE-Stat, https://www.umweltbundesamt.de/publikationen/emissionsbilanz-erneuerbarer-energietrager-2024. Values converted from g/kWh to kg/kWh; no other change. Normalised by open-climate.ai, https://open-climate.ai/factors/libraries/uba_de/ (CC BY 4.0). https://open-climate.ai/factors/ef-ubade-deutscher_strommix-de-kwh-generation-c4f004f3/?v=efv1-0299fef17d22d7e250b8d2bf55be1515
Something looks wrong?
Tell us which value and why. We check it against the source and answer within a week.