Emission factor from UBA (DE)

Natural gas, petroleum gas - Gross electricity generation

Germany · Well-to-use · Any year

Each kilowatt-hour of gross output, measured at the generator before the plant's own use and network losses, counts as 0.441 kg CO₂e, including 0.376 at the power plants.

Value for any year

0.441kgCO₂e/kWh gross output

Biogenic CO₂ and land use excluded · GWP100 · AR6

FossilBio CH₄Land useBio CO₂GHG Protocol and IPCC inventories

One value, for any year

UBA (DE) sets no date window, so there is no year to pick.

Reference year 2024

Region
Germany DE
Boundary
Well-to-use
Data quality
MediumRated by us, not by the source
Licence
Open · UBA (DE) terms

Where 0.441 comes from

0.376 of it sits inside the total, 0.441, and is never added to it. The other 0.0644 is not published as a part of its own.

Reporting this kilowatt-hour under the GHG Protocol

Scope 2 + 3.3 Energy upstream 0.441

This one figure covers both together; no split between them is given.

This is the plant's output at its generator terminals, before the grid: whoever buys that energy reports its generation as Scope 2.

The fuel behind it and the energy lost on the way to you are Scope 3, category 3.

CiteAPI

The factor, standardised

Every factor on open-climate.ai answers the same questions in the same words, whatever the publisher. Open any ⓘ for the definition.

Electricity › Electricity by generation technology · Germany · per kWh gross output · Average

Well-to-use · Excl. biogenic CO₂ · AR6

Boundary
Well-to-use
Fuel supply, generation and capital goods
GWP method
IPCC AR6, 100-year horizon
Re-weighted by open-climate.ai from UBA (DE)'s AR5 figure of 0.438 kgCO₂e/kWh gross output
CO₂e basis
Excl. biogenic CO₂FossilBio CH₄Land useBio CO₂GHG Protocol and IPCC inventories
Split by gas
Life cycle
Upstream: partly coveredProduction: coveredDownstream: not applicableEnd of life: not applicable

Medium quality · Open licence · Any year

What this number covers

The path of one kilowatt-hour of gross output, from the fuel to the generator terminals. Every step on it is counted.

  1. Generation

    Producing the electricity at the power plants that make up the mix

    IncludedScope 20.376
  2. Generator terminals

    1 kWh of gross output, measured at the generator terminals before the plant's own use.

    = 0.441

Outside this boundary

  • Building the grid

Capital goods and infrastructure sit outside every well-to-use factor, in every library.

Gases

Basis: Excl. biogenic CO₂FossilBio CH₄Land useBio CO₂GHG Protocol and IPCC inventories

  • Fossil CO₂0.39289.1%
  • Methane (CH₄)0.045610.3%
  • Nitrous oxide (N₂O)0.002490.6%

Σ 0.392 + 0.0456 + 0.00249 = 0.441.

Each gas is converted to CO₂e with AR6 100-year warming potentials; biogenic CO₂ and land-use carbon are left out, while methane from biogenic sources is counted.

From UBA (DE)'s record to a comparable factor

UBA (DE) publishes this factor as one German record. Here is each field as printed and what open-climate.ai made of it.

The total and its parts

Each part has its own page, with its own years and source record. Never add a part to the total.

You are here · the totalNatural gas, petroleum gas, gross electricity generation, well-to-use0.441

About this factor

UBA (DE) gives no description for this factor. Filed under Bruttostromerzeugung.

Source and licence

Publisher
Umweltbundesamt (UBA)
Published
1 September 2025
Open the record at UBA (DE)

The values and their metadata are served in full and may be reused with credit to the publisher.

Used with the written consent of the Umweltbundesamt (2026-11-09), on condition that the source is acknowledged. The consent is not § 12a EGovG open data: UBA does not count these factors as unprocessed raw data.
Credit it with this lineSource: German Environment Agency (Umweltbundesamt), September 2025: Emissionsbilanz erneuerbarer Energieträger, unter Verwendung von Daten der AGEE-Stat, https://www.umweltbundesamt.de/publikationen/emissionsbilanz-erneuerbarer-energietrager-2024. Values converted from g/kWh to kg/kWh; no other change.
A plain reading of the licence, not legal advice. The licence text prevails.

Cite this factor

Source: German Environment Agency (Umweltbundesamt), September 2025: Emissionsbilanz erneuerbarer Energieträger, unter Verwendung von Daten der AGEE-Stat, https://www.umweltbundesamt.de/publikationen/emissionsbilanz-erneuerbarer-energietrager-2024. Values converted from g/kWh to kg/kWh; no other change. Normalised by open-climate.ai, https://open-climate.ai/factors/libraries/uba_de/ (CC BY 4.0). https://open-climate.ai/factors/ef-ubade-erdgas_erdolgas-de-kwh_gross_ou-well_to_wheel-1e16c71d/?v=efv1-26c909fdb65584ee01e4175664beb1a7

Something looks wrong?

Tell us which value and why. We check it against the source and answer within a week.

Page data as of .