Emission factor from UBA (DE)
Fossil district heating mix - Final energy consumption, heat & cooling
Germany · Generation and upstream · Any year
Each kilowatt-hour of heat or steam bought counts as 0.319 kg CO₂e, including 0.266 for generating it.
Value for any year
0.319kgCO₂e/kWh
Biogenic CO₂ and land use excluded · GWP100 · AR6
FossilBio CH₄Land useBio CO₂GHG Protocol and IPCC inventoriesOne value, for any year
UBA (DE) sets no date window, so there is no year to pick.
Reference year 2024
- Region
- Germany DE
- Boundary
- Generation and upstream
- Data quality
- MediumRated by us, not by the source
- Licence
- Open · UBA (DE) terms
Where 0.319 comes from
- Scope 20.26683.4%
0.266 of it sits inside the total, 0.319, and is never added to it. The other 0.0529 is not published as a part of its own.
Reporting this kilowatt-hour under the GHG Protocol
Scope 2 + 3.3 Energy upstream 0.319
This one figure covers both together; no split between them is given.
You buy the energy, so its generation is your Scope 2.
The fuel behind it and the energy lost on the way to you are Scope 3, category 3.
The factor, standardised
Every factor on open-climate.ai answers the same questions in the same words, whatever the publisher. Open any ⓘ for the definition.
Heat and cooling › District heat and steam · Germany · per kWh · Average
Generation and upstream · Excl. biogenic CO₂ · AR6
- BoundaryGeneration and upstreamEverything before the network: one unit of a delivered energy carrier priced from the well to the plant, so the generation plus the well-to-tank chain of the fuel it burns, without the transmission and distribution losses between the plant and the point of use. Learn more
- Generation and upstream
- Fuel supply and generation
- GWP methodWhich IPCC assessment report's warming potentials convert each gas to CO₂e, and over how many years the warming is counted (GWP100: 100 years). Learn more
- IPCC AR6, 100-year horizon
- Re-weighted by open-climate.ai from UBA (DE)'s AR5 figure of 0.317 kgCO₂e/kWh
- CO₂e basisWhich carbon the CO₂e counts. Fossil only leaves out biogenic methane, land-use change and biogenic CO₂; excl. biogenic CO₂ counts biogenic methane but not the other two; net total counts every pool, net of removals. The same activity on two bases is two different numbers. Learn more
- Excl. biogenic CO₂FossilBio CH₄Land useBio CO₂GHG Protocol and IPCC inventories
- Split by gas
Medium quality · Open licence · Any year
What this number covers
The path of one kilowatt-hour of heat, from the fuel to your meter. Not every step on it is counted; what is left out is listed below.
Combustion (direct, at point of use)
IncludedScope 20.266Your meter
1 kWh used. The factor is per kWh measured here.
= 0.319
Outside this boundary
- Heat lost in the network
- Building the heat plants
- Building the heat network
UBA (DE) counts running the heat plants, not building them.
Gases
Basis: Excl. biogenic CO₂Biogenic CO₂ and land-use change are left out; fossil CO₂, the other greenhouse gases and methane from biogenic sources are counted. Learn moreFossilBio CH₄Land useBio CO₂GHG Protocol and IPCC inventories
- Fossil CO₂0.29191.3%
- Methane (CH₄)0.02628.2%
- Nitrous oxide (N₂O)0.001640.5%
Σ 0.291 + 0.0262 + 0.00164 = 0.319.
Each gas is converted to CO₂e with AR6 100-year warming potentials; biogenic CO₂ and land-use carbon are left out, while methane from biogenic sources is counted.
From UBA (DE)'s record to a comparable factor
UBA (DE) publishes this factor as one German record. Here is each field as printed and what open-climate.ai made of it.
The total and its parts
Each part has its own page. Never add a part to the total.
About this factor
UBA (DE) gives no description for this factor. Filed under Endenergieverbrauch Wärme & Kälte.
Source and licence
- Publisher
- Umweltbundesamt (UBA)
- Library
- UBA (DE) Data year 2024
- Published
- 1 September 2025
The values and their metadata are served in full and may be reused with credit to the publisher.
Used with the written consent of the Umweltbundesamt (2026-11-09), on condition that the source is acknowledged. The consent is not § 12a EGovG open data: UBA does not count these factors as unprocessed raw data.
Cite this factor
Source: German Environment Agency (Umweltbundesamt), September 2025: Emissionsbilanz erneuerbarer Energieträger, unter Verwendung von Daten der AGEE-Stat, https://www.umweltbundesamt.de/publikationen/emissionsbilanz-erneuerbarer-energietrager-2024. Values converted from g/kWh to kg/kWh; no other change. Normalised by open-climate.ai, https://open-climate.ai/factors/libraries/uba_de/ (CC BY 4.0). https://open-climate.ai/factors/ef-ubade-fossiler_fernwarmemix-de-kwh-well_to_wheel-de38f57d/?v=efv1-f4600bb6ff2d8cc44a144986c2543cc2
Something looks wrong?
Tell us which value and why. We check it against the source and answer within a week.
Page data as of .