Emission factor from ADEME Base Carbone
Anthracite
Mainland France, excluding Corsica · Well-to-use · 2015 onwards
Each kilowatt-hour of this fuel from 2015 counts as 0.387 kg CO₂e: 0.356 from burning it and 0.0305 for producing it and bringing it to you.
Value per kWh, net calorific value
0.387kgCO₂e/kWh
Net calorific value · Biogenic CO₂ and land use excluded · GWP100 · AR6
FossilBio CH₄Land useBio CO₂GHG Protocol and IPCC inventories- Region
- Mainland France, excluding Corsica
- Boundary
- Well-to-use
- Data quality
- HighNo reason given by the publisher
- Licence
- Open · ADEME terms
Where 0.387 comes from
- Scope 10.35692%
- 3.3 Energy upstream0.03057.9%
Σ 0.386: the two parts do not add up to ADEME's total, 0.387. The total is the value.
Reporting this kilowatt-hour under the GHG Protocol
Scope 1 0.356 3.3 Energy upstream 0.0305
You burn the fuel, so its combustion is your Scope 1.
Supplying the fuel is Scope 3, category 3 for whoever burns it.
The factor, standardised
Every factor on open-climate.ai answers the same questions in the same words, whatever the publisher. Open any ⓘ for the definition.
Fuels › Solid fossil fuels · Mainland France, excluding Corsica · per kWh · Average
Well-to-use · Excl. biogenic CO₂ · AR6
- BoundaryWell-to-useOne unit of energy as consumed, priced from the well to the point of use: the well-to-tank chain plus the burn for a fuel; generation, its well-to-tank and the transmission and distribution losses for a delivered carrier (electricity, steam or hot water, chilled water). Learn more
- Well-to-use
- Fuel supply and fuel combustion
- GWP methodWhich IPCC assessment report's warming potentials convert each gas to CO₂e, and over how many years the warming is counted (GWP100: 100 years). Learn more
- IPCC AR6, 100-year horizon
- Not on the record; set from ADEME's method notes
- CO₂e basisWhich carbon the CO₂e counts. Fossil only leaves out biogenic methane, land-use change and biogenic CO₂; excl. biogenic CO₂ counts biogenic methane but not the other two; net total counts every pool, net of removals. The same activity on two bases is two different numbers. Learn more
- Excl. biogenic CO₂FossilBio CH₄Land useBio CO₂GHG Protocol and IPCC inventories
- Split by gas
High quality · Open licence · 2014 to now
Burning it, and getting it to you
Combustion is almost all CO₂. Methane and nitrous oxide are there too, too small to see at this scale, so they are drawn again below, 100 times larger.
- CombustionScope 10.356
- Well-to-tank3.3 Energy upstream0.0305
- CH₄0.0001
- N₂O0.00147
| Part | Gas | kgCO₂e/kWh | Share | Scope |
|---|---|---|---|---|
| Combustion | CO₂ | 0.354 | 91.5% | Scope 1 |
| Combustion | CH₄ | 0.0001 | <0.1% | Scope 1 |
| Combustion | N₂O | 0.00147 | 0.4% | Scope 1 |
| Combustion, all gases | CO₂e | 0.356 | 92% | Scope 1 |
| Well-to-tank | CO₂e | 0.0305 | 7.9% | 3.3 Energy upstream |
| Total, well-to-use | CO₂e | 0.387 | 100% | Both |
All values
2 values, one per year back to 2014. Every one is biogenic CO₂ and land use excluded, AR6 GWP100, so the years compare directly. Tap a bar.
2015 onwards0.387Default value
What this number covers
The path of one kilowatt-hour of this fuel, from the well to your flame. ADEME gives one figure for the first three steps together.
Well-to-tank0.03053.3 Energy upstream
Extraction
Getting the fuel out of the ground
Processing
Treating it to the quality it is sold at
Transport
Moving it to your site
Your meter
1 kWh used. The factor is per kWh measured here.
Burning it
In your boiler, furnace or engine: CO₂, with a little CH₄ and N₂O
Scope 10.356
0.0305 + 0.356 = 0.387 per kWh
Outside this boundary
- Making the boiler that burns it
- Building the pipelines and the network
ADEME counts the fuel, not the things built to extract, move and burn it.
Gases
Basis: Excl. biogenic CO₂Biogenic CO₂ and land-use change are left out; fossil CO₂, the other greenhouse gases and methane from biogenic sources are counted. Learn moreFossilBio CH₄Land useBio CO₂GHG Protocol and IPCC inventories
- Fossil CO₂0.36694.8%
- Methane (CH₄)0.01874.8%
- Nitrous oxide (N₂O)0.001470.4%
Σ 0.366 + 0.0187 + 0.00147 = 0.38617, which ADEME rounds to 0.387.
Also printed, as zero: biogenic methane (CH₄), other gases and biogenic CO₂.
Each gas is converted to CO₂e with AR6 100-year warming potentials; biogenic CO₂ and land-use carbon are left out, while methane from biogenic sources is counted.
From ADEME's record to a comparable factor
ADEME publishes this factor as one French record with two sub-lines, and a new record every year. Here is each field as printed and what open-climate.ai made of it.
The total and its parts
Each part has its own page. Use a part on its own when you report Scope 1 and Scope 3 separately; never add a part to the total.
About this factor
ADEME gives no description for this factor. Filed under Combustibles › Fossiles › Solides › Charbons.
Source and licence
- Publisher
- ADEME
- Library
- Base Carbone v23.11
- Record
- 12902
- Published
- 18 June 2026
- Valid until
- 31 December 2018
- Status
- Valide générique
The values and their metadata are served in full and may be reused with credit to the publisher.
Pour les jeux de données issus de Base Carbone® et de Base IMPACTS®, aucune restriction n'est formulée mis à part le fait de céder ou de transférer partiellement ou totalement la propriété des jeux de données à un tiers. … L'utilisateur peut : … Mettre ces jeux de données à disposition dans un outil pour un usage par un tiers. L'utilisateur NE peut PAS : Vendre ou accorder des droits de licence à un tiers ; Céder ou transférer la propriété des jeux de données.
Cite this factor
Source ADEME, Base Carbone v23.11. Normalised by open-climate.ai, https://open-climate.ai/factors/libraries/ademe/ (CC BY 4.0). https://open-climate.ai/factors/ef-ademe-anthracite-fr-kwh-well_to_use-a2e28919/?v=efv1-9c9ab899954d9eb826413a0f086dc066
Something looks wrong?
Tell us which value and why. We check it against the source and answer within a week.
Page data as of .