Emission factor from ADEME Base Carbone
Electricity - wind turbine on land
Mainland France, excluding Corsica · Well-to-use · Any year
Each kilowatt-hour generated this way counts as 0.0141 kg CO₂e: 0 at the power plants and 0.0141 for the fuel supplied to the power plants.
Value for any year
0.0141kgCO₂e/kWh
Biogenic CO₂ and land use excluded · GWP100 · AR6
FossilBio CH₄Land useBio CO₂GHG Protocol and IPCC inventoriesOne value, valid until 31 December 2020
ADEME sets this validity and gives no value for another period, so there is no year to pick.
Reference year 2019
- Region
- Mainland France, excluding Corsica
- Boundary
- Well-to-use
- Data quality
- LowNo reason given by the publisher
- Licence
- Open · ADEME terms
Where 0.0141 comes from
- Scope 200%
- 3.3 Energy upstream0.0141100%
Σ 0.0141: the two parts add up to ADEME's published total.
Reporting this kilowatt-hour under the GHG Protocol
Scope 2 0 3.3 Energy upstream 0.0141
You buy the energy, so its generation is your Scope 2.
Extracting, refining and delivering the fuel behind it happens upstream: Scope 3, category 3.
The factor, standardised
Every factor on open-climate.ai answers the same questions in the same words, whatever the publisher. Open any ⓘ for the definition.
Electricity › Electricity by generation technology · Mainland France, excluding Corsica · per kWh · Average
Well-to-use · Excl. biogenic CO₂ · AR6
- BoundaryWell-to-useOne unit of energy as consumed, priced from the well to the point of use: the well-to-tank chain plus the burn for a fuel; generation, its well-to-tank and the transmission and distribution losses for a delivered carrier (electricity, steam or hot water, chilled water). Learn more
- Well-to-use
- Fuel supply, generation and capital goods
- GWP methodWhich IPCC assessment report's warming potentials convert each gas to CO₂e, and over how many years the warming is counted (GWP100: 100 years). Learn more
- IPCC AR6, 100-year horizon
- Not on the record; set from ADEME's method notes
- CO₂e basisWhich carbon the CO₂e counts. Fossil only leaves out biogenic methane, land-use change and biogenic CO₂; excl. biogenic CO₂ counts biogenic methane but not the other two; net total counts every pool, net of removals. The same activity on two bases is two different numbers. Learn more
- Excl. biogenic CO₂FossilBio CH₄Land useBio CO₂GHG Protocol and IPCC inventories
- Not split by gas; CO₂e only
- Life cycle
- Upstream: partly coveredProduction: coveredDownstream: not applicableEnd of life: not applicable
Low quality · Open licence · Any year
What this number covers
The path of one kilowatt-hour, from the fuel to your meter. Not every step on it is counted; what is left out is listed below.
Fuel supply
Extracting, processing and transporting the fuel the plants burn
Included3.3 Energy upstream0.0141Combustion (direct, at point of use)
IncludedScope 20Your meter
1 kWh used. The factor is per kWh measured here.
= 0.0141
Outside this boundary
- Electricity lost on the network
- Building the grid
Capital goods and infrastructure sit outside every well-to-use factor, in every library.
Gases
ADEME publishes this factor as CO₂e only, with no split by gas. The CO₂e leaves biogenic CO₂ and land-use carbon out; methane from biogenic sources is counted.
From ADEME's record to a comparable factor
ADEME publishes this factor as one French record with two sub-lines. Here is each field as printed and what open-climate.ai made of it.
The total and its parts
Each part has its own page, with its own years and source record. Use a part on its own when you report Scope 2 and Scope 3 separately; never add a part to the total.
About this factor
From ADEME
Data derived from an LCA study. Functional unit: "1 kilowatt-hour from French onshore wind production capacity in 2013, delivered to the electricity grid, with an average capacity factor calculated over the previous 5 years (2010-2014), for a farm lifetime of 20 years"Show ADEME's original (French)
Donnée issue d'une étude ACV. Unité fonctionnelle : «1 kilowattheure issu de la capacité de production éolienne française terrestre en 2013, délivré sur le réseau électrique, avec un facteur de charge moyen calculé sur les 5 dernières années (2010-2014), pour une durée de vie de parc de 20 ans»Source and licence
- Publisher
- ADEME
- Library
- Base Carbone v23.11
- Record
- 26033
- Published
- 18 June 2026
- Valid until
- 31 December 2020
- Status
- Valide générique
The values and their metadata are served in full and may be reused with credit to the publisher.
Pour les jeux de données issus de Base Carbone® et de Base IMPACTS®, aucune restriction n'est formulée mis à part le fait de céder ou de transférer partiellement ou totalement la propriété des jeux de données à un tiers. … L'utilisateur peut : … Mettre ces jeux de données à disposition dans un outil pour un usage par un tiers. L'utilisateur NE peut PAS : Vendre ou accorder des droits de licence à un tiers ; Céder ou transférer la propriété des jeux de données.
Cite this factor
Source ADEME, Base Carbone v23.11. Normalised by open-climate.ai, https://open-climate.ai/factors/libraries/ademe/ (CC BY 4.0). https://open-climate.ai/factors/ef-ademe-electricity_wind_turbine-fr-kwh-well_to_wheel-8b37ace0/?v=efv1-ea85212a0d689517f0561cb9651d576f
Something looks wrong?
Tell us which value and why. We check it against the source and answer within a week.