Emission factor from CO2emissiefactoren.nl 2026

R407c

Netherlands · Fugitive releases · 2026 onwards

Each kilogram of R407c released to the air from 2026 counts as 1,908 kg CO₂e, its 100-year warming potential under IPCC AR6.

Value for R407c, per kg leaked

1,908kgCO₂e/kg

Leak to air · GWP100 · IPCC AR6

2026–
Default: the latest yearUnchanged on 2025

1 kg leaked = 1,908 kg CO₂e

The same warming over 100 years as releasing 1,908 kg of carbon dioxide.

Refrigerant you topped up this year

1 kg= 1,908 kg CO₂e

No top-up records? Charge × yearly leak rate gives the kilograms.

Region
Netherlands NL
Boundary
Fugitive releases
Data quality
HighRated by us, not by the source
Licence
Open · CO2emissiefactoren.nl terms

Where 1,908 comes from

Published as one number

CO2emissiefactoren.nl prints this factor as a single figure, with no parts to add up and no split by gas.

Reporting this kilogram under the GHG Protocol

Scope 1 1,908

Gas that escapes from equipment you run is a direct emission, so it is your Scope 1.

CiteAPI

The factor, standardised

Every factor on open-climate.ai answers the same questions in the same words, whatever the publisher. Open any ⓘ for the definition.

Direct emissions › Fugitive emissions and refrigerants · Netherlands · per kg · Average

Fugitive releases · Excl. biogenic CO₂ · AR6

Boundary
Fugitive releases
GWP method
IPCC AR6, 100-year horizon
As printed by CO2emissiefactoren.nl
CO₂e basis
Excl. biogenic CO₂FossilBio CH₄Land useBio CO₂GHG Protocol and IPCC inventories
Not split by gas; CO₂e only

High quality · Open licence · 2020 to now

Every horizon, every IPCC report

A warming potential rests on two choices: how many years of warming are counted, and which IPCC assessment report supplies the numbers. CO2emissiefactoren.nl publishes 3 of these 9 cells; the other 6 read “Not published by CO2emissiefactoren.nl”.

This factor1,908 AR6, GWP100
Cells published for R407c3 of 9 100 years only
kgCO₂e per kg of R407c leaked, by horizon and IPCC report. Pick a cell to read it.
AR4IPCC, 2007AR5IPCC, 2013AR6IPCC, 2021
GWP2020 years
Not published by CO2emissiefactoren.nl
Not published by CO2emissiefactoren.nl
Not published by CO2emissiefactoren.nl
GWP100100 years
GWP500500 years
Not published by CO2emissiefactoren.nl
Not published by CO2emissiefactoren.nl
Not published by CO2emissiefactoren.nl

Default: what search and the API return when you ask for nothing specificNot published by CO2emissiefactoren.nl

R407C: every publisher's GWP, side by side

What this number covers

One step: refrigerant leaving your equipment. Your records give the kilograms; the factor converts them.

  1. Refrigerant in your equipment

    The charge in a heat pump, air-conditioning unit or chiller. No emission while it stays in the circuit.

    Starting point, not counted
  2. Leak to air

    Refrigerant lost through seals and joints, during servicing, or in a failure. Counted as the kilograms you top up.

    Included1 kg
  3. Warming over 100 years

    Heat trapped by that kilogram, compared with 1 kg of CO₂: its GWP100 from the IPCC's sixth report.

    Included× 1,908
  4. Your footprint

    1 kg leaked, reported as CO₂e.

    = 1,908

Outside this boundary

  • Making the refrigerant
  • Recovery at end of life
  • Power the unit uses

Buying the gas is Scope 3, category 1, with its own factor, not this one.

A warming potential, not a measurement

Nobody measured this number at a site. It is the warming caused by 1 kg of the gas over 100 years, divided by the warming of 1 kg of CO₂. It is the same wherever the leak happens.

kg leaked × 1,908 = kg CO₂e

From CO2emissiefactoren.nl's record to a comparable factor

CO2emissiefactoren.nl publishes this factor as one Dutch record. Here is each field as printed and what open-climate.ai made of it.

About this factor

From CO2emissiefactoren.nl

What it is

Mixture: 23% R32; 25% R125; 52% R134a This value can be used to include the climate impact of leaking refrigerant in a CO₂‑inventory. The global warming potential (GWP) is calculated as the warming potential over a 100-year period of 1 kg of a gas relative to 1 kg of CO₂; emissions during production are not known and are not included. The total GWP for a mixture is calculated as the weighted average of its components.

What it includes

The global warming potential (GWP) is calculated as the warming potential over a 100-year period of 1 kg of a gas relative to 1 kg of CO₂; emissions during production are not known and are not included.

Where it applies

Mixture: 23% R32; 25% R125; 52% R134a This value can be used to include the climate impact of leaking refrigerant in a CO₂‑inventory.

Source and licence

Publisher
CO2emissiefactoren.nl (Rijkswaterstaat / Stichting Stimular)
Record
22 · factor number
Published
2026
Open the record at CO2emissiefactoren.nl

The values and their metadata are served in full and may be reused with credit to the publisher.

Credit it with this lineBron: Lijst CO2-emissiefactoren (co2emissiefactoren.nl), beheerd door Rijkswaterstaat en Stichting Stimular namens de Green Deal-partijen.
The publisher's text on this page is translated by open-climate.ai.A plain reading of the licence, not legal advice. The licence text prevails.

Cite this factor

Bron: Lijst CO2-emissiefactoren (co2emissiefactoren.nl), beheerd door Rijkswaterstaat en Stichting Stimular namens de Green Deal-partijen. Normalised by open-climate.ai, https://open-climate.ai/factors/libraries/co2emissiefactoren_nl/ (CC BY 4.0). https://open-climate.ai/factors/ef-co2emissiefactor-r407c-nl-kg-fugitive-6f167a8f/?v=efv1-39d359a9f92bef1ac3b709d2a4ab65ec

Something looks wrong?

Tell us which value and why. We check it against the source and answer within a week.

Page data as of .