Emission factor from CO2emissiefactoren.be 2026.06

Residual heat without supplementary firing

Belgium · Well-to-use · 2025 onwards

Each kilowatt-hour of heat or steam bought from 2025 counts as 0.0407 kg CO₂e: 0.0335 for generating it and 0.0072 for the fuel supplied to the plant.

Value from 2025 onwards

0.0407kgCO₂e/kWh

Biogenic CO₂ and land use excluded · GWP100 · GWP vintage not stated

FossilBio CH₄Land useBio CO₂GHG Protocol and IPCC inventories
2025–
Default: the latest year+28.4% on –2024
Region
Belgium BE
Boundary
Well-to-use
Data quality
MediumRated by us, not by the source
Licence
Open · CO2emissiefactoren.be terms

Where 0.0407 comes from

Σ 0.0407: the two parts add up to CO2emissiefactoren.be's published total.

Reporting this kilowatt-hour under the GHG Protocol

Scope 2 0.0335 3.3 Energy upstream 0.0072

You buy the energy, so its generation is your Scope 2.

Extracting, refining and delivering the fuel behind it happens upstream: Scope 3, category 3.

CiteAPI

The factor, standardised

Every factor on open-climate.ai answers the same questions in the same words, whatever the publisher. Open any ⓘ for the definition.

Heat and cooling › District heat and steam · Belgium · per kWh · Average

Well-to-use · Excl. biogenic CO₂

Boundary
Well-to-use
Fuel supply and generation
GWP method
Not stated by the publisher
CO₂e basis
Excl. biogenic CO₂FossilBio CH₄Land useBio CO₂GHG Protocol and IPCC inventories
Not split by gas; CO₂e only

Medium quality · Open licence · 2024 to now

Heat from a network, or from your own boiler

A heat network and your own boiler burn the same fuel. What changes is the scope the burning lands in.

The same 0.0335 of combustion, two scopes

  • The network's boiler burns the fuelScope 2It reaches you as heat you buy
  • Your own boiler burns the fuelScope 1It leaves your own flue

All values

2 values, one per year back to 2024. Every one is biogenic CO₂ and land use excluded, GWP not stated by the publisher, so the years compare directly. Tap a bar.

2025 onwards0.0407Default value

kgCO₂e per kWh, by year, split into its 2 parts. Pick a year to read it.

What this number covers

The path of one kilowatt-hour of heat, from the fuel to your meter. Every step on it is counted.

  1. Fuel supply

    Extracting, processing and transporting the fuel the heat plants burn

    Included3.3 Energy upstream0.0072
  2. Heat generation

    Producing the heat and steam at the plants that feed the network

    IncludedScope 20.0335
  3. Your meter

    1 kWh used. The factor is per kWh measured here.

    = 0.0407

Outside this boundary

  • Building the heat plants
  • Building the heat network

Capital goods and infrastructure sit outside every well-to-use factor, in every library.

Gases

CO2emissiefactoren.be publishes this factor as CO₂e only, with no split by gas. The CO₂e leaves biogenic CO₂ and land-use carbon out; methane from biogenic sources is counted.

From CO2emissiefactoren.be's record to a comparable factor

CO2emissiefactoren.be publishes this factor as one Dutch record with two sub-lines, and a new record every year. Here is each field as printed and what open-climate.ai made of it.

The total and its parts

Each part has its own page. Use a part on its own when you report Scope 2 and Scope 3 separately; never add a part to the total.

You are here · the totalResidual heat without supplementary firing, well-to-use0.0407

About this factor

From CO2emissiefactoren.be

This concerns the off-take of residual heat, where the customer itself covers the peaks at times when no or insufficient residual heat is available.

Source and licence

Publisher
CO2emissiefactoren.be (EnergieID & BENOR)
Record
Warmtelevering_NL.csv:10 · file and row
Published
16 June 2026
Valid from
1 January 2025

The values and their metadata are served in full and may be reused with credit to the publisher.

Credit it with this lineBron: CO2emissiefactoren.be, een initiatief van EnergieID en BENOR. © EnergieID & BENOR. Alle rechten voorbehouden.
The publisher's text on this page is translated by open-climate.ai.A plain reading of the licence, not legal advice. The licence text prevails.

Cite this factor

Bron: CO2emissiefactoren.be, een initiatief van EnergieID en BENOR. © EnergieID & BENOR. Alle rechten voorbehouden. Normalised by open-climate.ai, https://open-climate.ai/factors/libraries/co2emissiefactoren_be/ (CC BY 4.0). https://open-climate.ai/factors/ef-co2emissiefactor-restwarmte_zonder-be-kwh-well_to_wheel-3796261b/?v=efv1-7a949b09b31eb3ba0b0b6828720e9402

Something looks wrong?

Tell us which value and why. We check it against the source and answer within a week.

Page data as of .