Emission factor from CO2emissiefactoren.be 2026.06
Residual heat without supplementary firing
Belgium · Well-to-use · 2025 onwards
Each kilowatt-hour of heat or steam bought from 2025 counts as 0.0407 kg CO₂e: 0.0335 for generating it and 0.0072 for the fuel supplied to the plant.
Value from 2025 onwards
0.0407kgCO₂e/kWh
Biogenic CO₂ and land use excluded · GWP100 · GWP vintage not stated
FossilBio CH₄Land useBio CO₂GHG Protocol and IPCC inventories- Region
- Belgium BE
- Boundary
- Well-to-use
- Data quality
- MediumRated by us, not by the source
- Licence
- Open · CO2emissiefactoren.be terms
Where 0.0407 comes from
- Scope 20.033582.3%
- 3.3 Energy upstream0.007217.7%
Σ 0.0407: the two parts add up to CO2emissiefactoren.be's published total.
Reporting this kilowatt-hour under the GHG Protocol
Scope 2 0.0335 3.3 Energy upstream 0.0072
You buy the energy, so its generation is your Scope 2.
Extracting, refining and delivering the fuel behind it happens upstream: Scope 3, category 3.
The factor, standardised
Every factor on open-climate.ai answers the same questions in the same words, whatever the publisher. Open any ⓘ for the definition.
Heat and cooling › District heat and steam · Belgium · per kWh · Average
Well-to-use · Excl. biogenic CO₂
- BoundaryWell-to-useOne unit of energy as consumed, priced from the well to the point of use: the well-to-tank chain plus the burn for a fuel; generation, its well-to-tank and the transmission and distribution losses for a delivered carrier (electricity, steam or hot water, chilled water). Learn more
- Well-to-use
- Fuel supply and generation
- GWP methodWhich IPCC assessment report's warming potentials convert each gas to CO₂e, and over how many years the warming is counted (GWP100: 100 years). Learn more
- Not stated by the publisher
- CO₂e basisWhich carbon the CO₂e counts. Fossil only leaves out biogenic methane, land-use change and biogenic CO₂; excl. biogenic CO₂ counts biogenic methane but not the other two; net total counts every pool, net of removals. The same activity on two bases is two different numbers. Learn more
- Excl. biogenic CO₂FossilBio CH₄Land useBio CO₂GHG Protocol and IPCC inventories
- Not split by gas; CO₂e only
Medium quality · Open licence · 2024 to now
Heat from a network, or from your own boiler
A heat network and your own boiler burn the same fuel. What changes is the scope the burning lands in.
The same 0.0335 of combustion, two scopes
- The network's boiler burns the fuelScope 2It reaches you as heat you buy
- Your own boiler burns the fuelScope 1It leaves your own flue
All values
2 values, one per year back to 2024. Every one is biogenic CO₂ and land use excluded, GWP not stated by the publisher, so the years compare directly. Tap a bar.
2025 onwards0.0407Default value
| AppliesYears | TotalkgCO₂e/kWh | CO2emissiefactoren.be recordRecord |
|---|---|---|
| 0.0407Default value | Warmtelevering_NL.csv:10 | |
| 0.0317 | Warmtelevering_NL.csv:8 |
- Default: what search and the API return when you ask for nothing specific
What this number covers
The path of one kilowatt-hour of heat, from the fuel to your meter. Every step on it is counted.
Fuel supply
Extracting, processing and transporting the fuel the heat plants burn
Included3.3 Energy upstream0.0072Heat generation
Producing the heat and steam at the plants that feed the network
IncludedScope 20.0335Your meter
1 kWh used. The factor is per kWh measured here.
= 0.0407
Outside this boundary
- Building the heat plants
- Building the heat network
Capital goods and infrastructure sit outside every well-to-use factor, in every library.
Gases
CO2emissiefactoren.be publishes this factor as CO₂e only, with no split by gas. The CO₂e leaves biogenic CO₂ and land-use carbon out; methane from biogenic sources is counted.
From CO2emissiefactoren.be's record to a comparable factor
CO2emissiefactoren.be publishes this factor as one Dutch record with two sub-lines, and a new record every year. Here is each field as printed and what open-climate.ai made of it.
The total and its parts
Each part has its own page. Use a part on its own when you report Scope 2 and Scope 3 separately; never add a part to the total.
About this factor
From CO2emissiefactoren.be
This concerns the off-take of residual heat, where the customer itself covers the peaks at times when no or insufficient residual heat is available.Source and licence
- Publisher
- CO2emissiefactoren.be (EnergieID & BENOR)
- Record
- Warmtelevering_NL.csv:10 · file and row
- Published
- 16 June 2026
- Valid from
- 1 January 2025
The values and their metadata are served in full and may be reused with credit to the publisher.
Cite this factor
Bron: CO2emissiefactoren.be, een initiatief van EnergieID en BENOR. © EnergieID & BENOR. Alle rechten voorbehouden. Normalised by open-climate.ai, https://open-climate.ai/factors/libraries/co2emissiefactoren_be/ (CC BY 4.0). https://open-climate.ai/factors/ef-co2emissiefactor-restwarmte_zonder-be-kwh-well_to_wheel-3796261b/?v=efv1-7a949b09b31eb3ba0b0b6828720e9402
Something looks wrong?
Tell us which value and why. We check it against the source and answer within a week.
Page data as of .