CO2emissiefactoren.be - CO2emissiefactoren.be (EnergieID & BENOR)

The Belgian list of CO2 emission factors for fuels, electricity, heat, passenger transport, refrigerants and waste, run by EnergieID and BENOR.

Non-profitGeneralistOpen licence
Factors
512
Values
938

One per year and method

Countries
1

1 region, sub-national included

Edition
2026.06

published 16 Jun 2026 · all versions

Last loaded
15 Nov 2026

Report a newer version

Overview

CO2emissiefactoren.be is a private initiative that compiles emission factors for Belgian organisations and shares them as a tool. It is published on co2emissiefactoren.be as a downloadable set of files, released at irregular intervals.

The publisher states that it is not an official government initiative and that all values are indicative. Many rows take their value from the Dutch list at co2emissiefactoren.nl, which is a separate library here.

At a glance

Publisher
CO2emissiefactoren.be (EnergieID & BENOR)
Kind
Non-profit
Scope
Generalist4 categories each hold at least 5% of its factors; the largest, Fuels, holds 32.7%. A generalist needs 4.
Home region
Belgium
Edition
2026.06
Licence
Open licence (co2emissiefactoren-be-terms)

Standardised file

CO2emissiefactoren.be (EnergieID & BENOR), standardised by open-climate.ai

The publisher's file, re-cut into the schema every library on open-climate.ai shares: one category axis, coded regions, canonical units, AR6 warming potentials, the source row kept beside each value. What is in the file

  • Edition 2026.06
    derev 3 · 512 rows · built 2026-10-02 · 95fca3a027d3Licence requiredOpen data+
  • Edition 2026.06
    enrev 3 · 512 rows · built 2026-10-02 · b2a15aed9b9cfree account required
  • Edition 2026.06
    enrev 3 · 512 rows · built 2026-10-02 · 9655afec4c70Licence requiredOpen data+
  • Edition 2026.06
    frrev 3 · 512 rows · built 2026-10-02 · 434af749457fLicence requiredOpen data+

What open-climate.ai standardised

over the publisher's own fileHow we standardise

Warming potentials

1 factor value recalculated on AR6

40 factor values already on AR6

471 factor values left on the publisher's GWP

7 more things standardised

Parts and parents

304 factor values grouped under 208 parents

Use a part on its own, or the parent when you want the whole.

Languages

English: 100.0% of factor values

German: 100.0% of factor values

French: 100.0% of factor values

Norwegian Bokmål: 2.5% of factor values

Dutch: 100.0% of factor values

Swedish: 0.6% of factor values

Thai: 1.2% of factor values

Stable addresses

Slugs never break

143 old addresses redirect

Audit checks

143 passed3 known limitations3 enforced when loadedlast run 17 Nov 2026

Checks we run on every load to keep the data above trustworthy. Counts are for this library; the grey figure is the same check across all libraries. Point at the i to see why a check matters.

What the statuses meanHow checks are countedWhy we checkHow checks are grouped

Needs attention

  • A unit label that names no basis folds one way

    Known limitation · 1 in this library · 2 in all libraries

  • Every factor is filed under the most specific category its source allows

    Known limitation · 3 in this library · 7,103 in all libraries

  • Single-gas values have their AR6 version

    Known limitation · 1 in this library · 10 in all libraries

One category axis

Learn more
  • Every source category maps to our vocabulary

    Enforced when loaded

  • The publisher's classification is kept

    Passed

  • Every classification level has a valid parent

    Passed

  • Every product code comes with the codes above it

    Passed

  • A publisher's own classification is used only by that publisher

    Passed

  • A standard classification code has one label in every library

    Passed

Coded regions

Learn more
  • Every region is a known code

    Enforced when loaded

  • No named region is filed under a broader one

    Passed

  • Every region sits in the world hierarchy

    Passed

Canonical units

Learn more
  • Every unit is a known code

    Enforced when loaded

  • One source unit maps to one unit

    Passed

  • A unit label means the same in every library

    Passed

  • A unit label that names no basis folds one way

    Known limitation · 1 in this library · 2 in all libraries

Declared boundaries

Learn more
  • Every boundary states what it includes

    Passed

  • Boundary scope terms are known codes

    Passed

  • No two factors for the same activity partly overlap in scope

    Passed

  • Separate stages of one activity are linked as parts, or documented as having no total

    Passed

  • Every part of a factor states its boundary

    Passed

  • Every biofuel counted with its biogenic CO2 says how much

    Passed

  • No recycling credit is hidden inside a life-cycle total

    Passed

  • No burden value hides a sizeable credit inside it

    Passed · 13 in all libraries

Warming potentials

Learn more
  • Methane and nitrous oxide figures match the stated GWP

    Passed

  • Every convertible value has its AR6 version

    Passed

  • CO2e totals leave out what their basis excludes

    Passed

  • Where a library breaks its totals down by gas, every total is broken down or reviewed

    Passed · 693 in all libraries

  • Standardised figures keep every gas the publisher lists

    Passed

  • Every value states what its CO2e total includes

    Passed

  • A library with no AR6 version at all has a recorded reason

    Passed

Parts and parents

Learn more
  • Every part links to a valid parent

    Passed

  • No factor is an unlinked part of another factor

    Passed

  • No part is larger than the total it belongs to

    Passed

  • Every factor points to its top parent

    Passed

Electricity mix

Learn more
  • Every electricity factor states its mix

    Passed

  • The market-based value is the default

    Passed

  • One default value per factor and year

    Passed

  • Every green-electricity zero is a market-based value

    Passed

  • Green-electricity zeros are not rated below market-based peers

    Passed

Data quality

Learn more
  • Quality ratings fall inside their scale

    Passed

  • Every zero value is explained

    Passed

  • No default value is withheld without a stated reason

    Passed

  • No implausibly high per-kilogram value is rated reliable

    Passed

  • Every quality level gives a recognised reason

    Passed

  • A zero that is only a gap in the source is withheld

    Passed

  • The library is not rated entirely on one fallback quality level

    Passed

Languages

Learn more
  • Every factor has an English name

    Passed

  • Translations match the current source text

    Passed · 36 in all libraries

  • Translations follow a corrected source text

    Passed · 1 in all libraries

  • Recorded translations survive a reload

    Passed

  • Every served factor has a name

    Passed

  • Each factor's name is its English name or the publisher's own, never a mix of both

    Passed · 2 in all libraries

  • Every language with a main name also has a full name

    Passed

  • Full names are built from their parts in the same language

    Passed

  • Every text is labelled with its real language

    Passed

  • Every description is available for display and translation

    Passed

  • Every usage note is available for display and translation

    Passed

Traceable to the source

Learn more
  • Values traced to one source row agree with each other

    Passed

  • No duplicate factors are served

    Passed

  • No factor value claims two things that cannot both be true

    Passed

  • No energy factor answers a question about packaging or recycling

    Passed

  • Every served value past its publisher's end date has been reviewed

    Passed · 9 in all libraries

Other checks

  • One activity keeps one family across its units

    Passed · 8 in all libraries

  • An activity's grouping key names only the activity

    Passed · 2 in all libraries

  • A Creative Commons credit names its licence

    Passed

  • No note of ours appears in the credit or licence notice

    Passed

  • The credit line carries no terms of use

    Passed

  • Every impact assessment method is a recognised code

    Passed

  • Summed totals keep their parts' classification

    Passed

  • Every summed total has a classification when its parts do

    Passed

  • An avoided credit is linked to the burden it belongs to

    Passed

  • Every value is typed as specific, generic or average

    Passed

  • Summed totals equal their parts on every gas

    Passed

  • No total is served when one of its parts is withheld

    Passed

  • Validity dates are the publisher's own, never guessed

    Passed

  • Every district-heat factor says whether the network's heat loss is included

    Passed · 2 in all libraries

  • Quality breakdowns use their scheme's axes

    Passed

  • No battery-electric vehicle carries tailpipe emissions

    Passed

  • The text of each estimated electricity total matches its current figures

    Passed

  • No EPD value is wildly off its peers without a review

    Passed

  • Every estimated factor carries its description in each language

    Passed

  • The text of each estimated factor matches its current figures

    Passed

  • A total built on an estimated part is marked as estimated

    Passed

  • Every estimated district-heat leg still adds up from its sources

    Passed

  • Every estimate is built only from data we may redistribute

    Passed

  • No estimated factor is rated above the data it was built from

    Passed

  • No estimate sits beside a total of unclear scope

    Passed

  • No estimate repeats a stage the publisher's total already includes

    Passed

  • Every factor we complete has all of its estimated parts

    Passed · 247 in all libraries

  • No estimate is served where the publisher printed the figure

    Passed

  • We only estimate for publishers whose rule allows it

    Passed

  • Every estimated factor still matches the inputs it was computed from

    Passed

  • No estimated total competes with a published one

    Passed

  • Every factor with a current value has a default

    Passed

  • Every factor has a value, in a library that publishes values

    Passed

  • Only food, farming and land factors carry a FLAG split

    Passed

  • Every FLAG land-use change figure states its method and time frame

    Passed

  • Every total equals the sum of its SBTi FLAG split

    Passed

  • Every FLAG split says whether it was published or derived

    Passed

  • Fossil-only CO2 is filed as fossil

    Passed

  • The text of each fuel supply-chain estimate matches its current figures

    Passed

  • No fuel supply-chain estimate is rated above what its method allows

    Passed

  • Every fuel estimate is built only from data we may redistribute

    Passed

  • Every fuel eligible for a supply-chain estimate is classified

    Passed

  • No fuel estimate is served where the publisher printed the supply-chain figure

    Passed

  • No supply-chain estimate is served for a fuel we deliberately left out

    Passed

  • Every fuel supply-chain estimate still matches the figures it was computed from

    Passed

  • Per-gas values are in CO2e

    Passed

  • Every tagged gas has a known GWP

    Passed

  • Every fixed group of regions lists what it covers

    Passed

  • Where both exist, the residual mix is shown before the green-tariff zero

    Passed

  • The newest edition of each value is the one marked current

    Passed

  • Every publisher has a rule on whether we estimate its missing parts

    Passed

  • Factor descriptions describe the factor, not the whole library

    Passed

  • Every library's licence has its rights recorded

    Passed

  • No fossil electricity mix has a zero fuel supply chain

    Passed

  • Every green-electricity zero is exactly zero and says why

    Passed

  • Green-electricity zeros cover power generation only

    Passed

  • Only a total we computed may mix GWP vintages

    Passed

  • Spend factors state their price year and basis

    Passed

  • No electricity or heat factor answers network losses against its stage

    Passed

  • Every value has a number, a GWP version and a reference year

    Passed

  • Only a library cleared for it lists factors without their number

    Passed

  • Plug-in hybrid factors say when the electricity is left out

    Passed

  • A published total missing its fuel supply chain comes with a complete sum

    Passed

  • Product footprints headline fossil carbon, like EPDs

    Passed

  • No factor description is too long to display in full

    Passed · 11 in all libraries

  • The library-wide answers on what a factor covers are up to date

    Passed

  • Every library-wide answer applies to at least one factor

    Passed

  • Every excused arithmetic disagreement still matches the published figures

    Passed

  • Every reference year falls between 1960 and next year

    Passed

  • Each library's current edition is the one its values come from

    Passed

  • No two editions of a library share a release date

    Passed

  • The parts of a total are never listed twice under one label

    Passed

  • Every residual mix has its green-tariff counterpart

    Passed

  • Every conservative value carries the same label

    Passed

  • Every publisher's quality rating system is read

    Passed

  • Every factor's boundary includes what its category measures

    Passed

  • Every factor uses the most precise boundary for its category

    Passed

  • Every factor is filed under the most specific category its source allows

    Known limitation · 3 in this library · 7,103 in all libraries

  • Every factor has a category

    Passed

  • Every categorised factor has a GHG Protocol scope

    Passed · 39 in all libraries

  • Single-gas values have their AR6 version

    Known limitation · 1 in this library · 10 in all libraries

  • No factor answers a question that does not arise for it

    Passed · 9 in all libraries

  • A supplier named in the source is linked to the factor

    Passed

  • A part covering the same scope as its total is linked to it

    Passed

  • Every device total that includes its use also gives the manufacturing share (embodied emissions)

    Passed · 115 in all libraries

  • Every estimated vehicle fuel-supply leg matches its sources

    Passed

  • No plug-in vehicle supply-chain estimate is rated above what its method allows

    Passed

  • Every exhaust-only vehicle factor gets a fuel-supply leg or a recorded reason

    Passed

  • A year in a factor's name matches its reference year

    Passed

How the audit works

What can I do with this data?

Open licence · credit the publisher

Your rights

Open licence · co2emissiefactoren-be-terms
Use it to calculate my own footprint
Yes
Publish my footprint results
Yes, if
  • you credit the publisher
Share the file with my customers
Unclear: ask EnergieID & BENOR
Put the factors in a product I sell
Unclear: ask EnergieID & BENOR
Modify it or combine it with my own data
Unclear: ask EnergieID & BENOR

Our reading, where no written grant settles it, checked on 7 Oct 2026

Every page footer: "© EnergieID & BENOR. Alle rechten voorbehouden." (all rights reserved); the about page calls the list open source without naming a licence. Served on the owner's risk decision of 2026-09-14; the grant request is unanswered.

Credit line

Bron: CO2emissiefactoren.be, een initiatief van EnergieID en BENOR. © EnergieID & BENOR. Alle rechten voorbehouden. Normalised by open-climate.ai, https://open-climate.ai/factors/libraries/co2emissiefactoren_be/ (CC BY 4.0)

Not legal advice: the publisher's terms prevail.

Full terms

How to read these answers

Coverage

What the library covers, by category and by boundary. Click a slice to drill in, then a sub-category or a boundary to filter the factors below.

By category

Fuels: 68Transport: 59Direct emissions: 41Waste treatment: 30Electricity: 7Heat and cooling: 2Materials: 1
208factors

Click a slice to see what is under it. A name opens its category page; its swatch hides it from the ring.

By boundary

Energy, full chain: 111Direct only: 67End of life / waste: 30
208factors

Click a slice to see what is under it. Click a name to hide it from the ring.

Browse factors

top 0 matches

SavedUnfoldFactorRegionBoundary
Unit

Checked for updates 17 Nov 2026: the publisher still shows the edition we serve (2 signals watched)

VersionPublishedLoadedStatusSource
2026.0616 Jun 202615 Nov 2026ServedSource

Methodology

How this works
  • Values are kg CO2e per unit of activity. For fuels, vehicles, electricity, heat and passenger transport the list publishes a total with a use part (combustion) and a production part (upstream). We serve the total with its two parts as components, labelled Well-to-use.
  • Biogenic CO2 is left out of the total. Where the list publishes it, it is kept beside the value.
  • Only the refrigerant rows cite an IPCC assessment report, AR4 or AR6. Every other value states no GWP basis, so it shows as not stated.
  • One release carries every historical value, each with its own validity dates. The reference year is the start year of the validity window, or 2026 for the rows that carry no date. Values run from 2014 to 2026.
  • Grey electricity, a mix the publisher calls representative for Belgium, is served as a residual mix; electricity of unknown origin as a consumption mix. Green electricity is published per plant type; for biomass the publisher advises a supplier-specific factor instead.
  • Natural gas is published per kWh on both a net and a gross calorific value basis, as two factors. We never convert one into the other.
  • Other units are converted at fixed ratios only: district heat per GJ is served per kWh (× 0.0036), and green gas per Nm³ per litre (× 0.001). The 2026 average for heat networks, 40.45 kg CO2e per GJ, is served at 0.14562 kg CO2e per kWh. Green gas per Nm³ carries no conversion to kWh, because the list prints no heating value for it.
  • Waste factors are parallel routes, not parts of one total. Emissions avoided by recycling are negative and never netted.

Mixed: the start year of the value's published validity window, falling back to the release year on the 54 factors that state no window.

What we import

  • The 2026.06 release: seven section files covering fuels for vehicles, fuels for energy generation, electricity, heat supply, refrigerants, passenger transport and waste. 386 rows give 512 factors and 930 values, all placed in Belgium.
  • Every row, including those that cite the Dutch list as their source. The cited source is kept with each value.
  • The freight transport section holds no factors: the publisher refers to the Dutch list there.
  • Not imported: 14 rows marked withdrawn (vervallen) with no value, one row that refers to another factor instead of printing a number, and one exact duplicate row. The earlier release files are not read, since the 2026.06 release already carries their values as closed windows. Each excluded row is kept in our archive with its reason.
  • Names are published in Dutch. English and French names are machine translated.

Open, with a reservation. The site names no licence: it says the factors are shared openly as a tool, while every page carries the notice "© EnergieID & BENOR. Alle rechten voorbehouden." (all rights reserved). We serve the values with the publisher's credit line: "Bron: CO2emissiefactoren.be, een initiatief van EnergieID en BENOR. © EnergieID & BENOR. Alle rechten voorbehouden."

Before redistributing the values in a product of your own, confirm the terms with EnergieID and BENOR.

What can I do with this data?

Credit line: Bron: CO2emissiefactoren.be, een initiatief van EnergieID en BENOR. © EnergieID & BENOR. Alle rechten voorbehouden.

co2emissiefactoren-be-terms

Limitations

  • Values are indicative, with no quality rating or uncertainty. 279 of the 386 rows cite the Dutch list as their only source, so they describe the Netherlands rather than Belgium.
  • 58 factors serve a validity window that has already closed, with no successor: 6 closed in 2019, the rest in 2024 or 2025. Check the validity dates before use.
  • The refrigerant R600a (isobutane) still carries 3.0 kg CO2e per kg under an AR6 label, while its siblings propane and butane were corrected to their AR6 values.
  • As published, the battery electric bicycle's total (0.002 kg CO2e per vehicle-km) is below its own production part (0.022).
  • For the moped, the publisher prints two 2025 values (0.08 and 0.076) that differ only in their notes. We serve the one whose window is still open.
  • The date each row was last changed is not shown.

Changelog

  • 2026-09-15: fuel, electricity and transport totals relabelled Well-to-use.
  • 2026-09-14: values served openly with the publisher's credit line.
  • 2026-09-10: zero values for green electricity no longer rated lower in quality.
  • 2026-08-05: release 2026.06 loaded.

Highlighted factor pages

A selection of CO2emissiefactoren.be factors, with each value, boundary, source and derivation.

Know a newer edition?

If CO2emissiefactoren.be has published an edition we do not serve yet, tell us where to find it.