Each kilowatt-hour of this fuel counts as 0.403 kg CO₂e: 0.345 from burning it and 0.0583 for producing it and bringing it to you (estimated).
Value per kWh, net calorific value
0.403kgCO₂e/kWh
Net calorific value · Biogenic CO₂ and land use excluded · GWP100 · Mixed GWP vintages
FossilBio CH₄Land useBio CO₂GHG Protocol and IPCC inventoriesOne value, for any year
DCE sets no date window, so there is no year to pick.
Reference year 2024
EstimatedAn estimate by open-climate.ai, not a number the publisher printed. Where a fuel publisher prints combustion only, we add the supply chain before the burn (well-to-tank), computed by one stated rule from the publisher's own combustion value and a published supply-chain ratio. Learn more Summed by open-climate.ai from 2 parts, 1 of them estimated by us
- Region
- Denmark DK
- Boundary
- Well-to-use
- Data quality
- MediumRated by us, not by the source
- Licence
- Open · DCE terms
Where 0.403 comes from
- Scope 10.34585.5%
- Fuel supplyEstimatedAn estimate by open-climate.ai, not a number the publisher printed. Where a fuel publisher prints combustion only, we add the supply chain before the burn (well-to-tank), computed by one stated rule from the publisher's own combustion value and a published supply-chain ratio. Learn moreDerived by open-climate.ai3.3 Energy upstream0.058314.5%
Σ 0.403: open-climate.ai adds up the two parts. DCE prints fuel combustion. open-climate.ai estimates fuel supply from other published figures.
Reporting this kilowatt-hour under the GHG Protocol
Scope 1 0.345 3.3 Energy upstream 0.0583
You burn the fuel, so its combustion is your Scope 1.
Supplying the fuel is Scope 3, category 3 for whoever burns it.
The factor, standardised
Every factor on open-climate.ai answers the same questions in the same words, whatever the publisher. Open any ⓘ for the definition.
Fuels › Solid fossil fuels · Denmark · per kWh · Average
Well-to-use · Excl. biogenic CO₂
- BoundaryWell-to-useOne unit of energy as consumed, priced from the well to the point of use: the well-to-tank chain plus the burn for a fuel; generation, its well-to-tank and the transmission and distribution losses for a delivered carrier (electricity, steam or hot water, chilled water). Learn more
- Well-to-use
- Fuel supply and fuel combustion
- GWP methodWhich IPCC assessment report's warming potentials convert each gas to CO₂e, and over how many years the warming is counted (GWP100: 100 years). Learn more
- Mixed IPCC reports, 100-year horizon
- Not on the record; set from DCE's method notes
- CO₂e basisWhich carbon the CO₂e counts. Fossil only leaves out biogenic methane, land-use change and biogenic CO₂; excl. biogenic CO₂ counts biogenic methane but not the other two; net total counts every pool, net of removals. The same activity on two bases is two different numbers. Learn more
- Excl. biogenic CO₂FossilBio CH₄Land useBio CO₂GHG Protocol and IPCC inventories
- Not split by gas; CO₂e only
Medium quality · Open licence · Any year
What this number covers
The path of one kilowatt-hour of this fuel, from the well to your flame. DCE gives one figure for the first three steps together.
Well-to-tank0.05833.3 Energy upstream
Extraction
Getting the fuel out of the ground
Processing
Treating it to the quality it is sold at
Transport
Moving it to your site
Your meter
1 kWh used. The factor is per kWh measured here.
Burning it
In your boiler, furnace or engine: CO₂, with a little CH₄ and N₂O
Scope 10.345
0.0583 + 0.345 = 0.403 per kWh
Outside this boundary
- Making the boiler that burns it
- Building the pipelines and the network
DCE counts the fuel, not the things built to extract, move and burn it.
Gases
DCE publishes this factor as CO₂e only, with no split by gas. The CO₂e leaves biogenic CO₂ and land-use carbon out; methane from biogenic sources is counted.
From DCE's record to a comparable factor
DCE publishes one of the two parts; open-climate.ai estimated the others and added them all up to this total. Here is each field as printed and what open-climate.ai made of it.
The total and its parts
Each part has its own page. Use a part on its own when you report Scope 1 and Scope 3 separately; never add a part to the total.
About this factor
Source and licence
- Value
- Summed by open-climate.ai from its parts
- Publisher
- DCE – Danish Centre for Environment and Energy, Aarhus University
- Library
- DCE 2024
- Published
- 2 January 2026
The values and their metadata are served in full and may be reused with credit to the publisher.
Reproduction permitted provided the source is explicitly acknowledged
Cite this factor
Source: DCE – Danish Centre for Environment and Energy, Aarhus University. Emission factors used in the Danish national emission inventories, 2024. Normalised by open-climate.ai, https://open-climate.ai/factors/libraries/dce_denmark/ (CC BY 4.0). https://open-climate.ai/factors/ef-dcedenmark-coal_machinery-dk-kwh-well_to_use-a0f81d08/?v=efv1-70cbab122d6ce632939fad26c909e1de
Something looks wrong?
Tell us which value and why. We check it against the source and answer within a week.
Page data as of .