DCE - DCE – Danish Centre for Environment and Energy, Aarhus University

Denmark's national combustion emission factors for stationary plants and mobile sources, by fuel and technology, as used in the Danish national emission inventories and published by DCE, the Danish Centre for Environment and Energy at Aarhus University.

ResearchSpecialistRestricted licence
Factors
1,160
Values
1,160

One per year and method

Countries
1

1 region, sub-national included

Edition
2024

published 2 Jan 2026 · all versions

Last loaded
1 Oct 2026

Report a newer version

Overview

DCE compiles Denmark's national emission inventories for the UNFCCC, the EU and the UNECE air convention. On its emission factors page it publishes the emission factors those inventories use, as web tables revised every year. The edition loaded is data year 2024: the stationary combustion table stamped 31 December 2025 and the mobile sources table stamped 2 January 2026.

The stationary table gives one factor per fuel and SNAP process code: public power, district heating, each industry branch, commercial and institutional plants, households and agriculture, split further by technology such as boilers, gas turbines and engines. The mobile table gives one factor per fuel and source: road vehicles by vehicle type and road type (urban, rural, highway), mopeds and motorcycles, air traffic below and above 3,000 feet, railways, national and international sea traffic, fishing, recreational craft, the military, and the machinery of industry, agriculture, forestry, households and gardening.

For electricity, DCE's page points to Energinet, which estimates the environmental declarations for Danish electricity. This library holds fuels only.

At a glance

Publisher
DCE – Danish Centre for Environment and Energy, Aarhus University
Kind
Research
Scope
Specialist
Home region
Denmark
Edition
2024
Licence
Restricted licence (au-web-copyright-notice)

What open-climate.ai standardised

over the publisher's own fileHow we standardise
7 more things standardised

Parts and parents

600 factor values grouped under 560 parents

Use a part on its own, or the parent when you want the whole.

Estimated fuel legs

300 estimated supply-chain legs (well-to-tank) the publisher does not print

300 totals over burning and supply

Audit checks

117 passed2 known limitations3 enforced when loadedlast run 5 Oct 2026

Checks we run on every load to keep the data above trustworthy. Counts are for this library; the grey figure is the same check across all libraries. Point at the i to see why a check matters.

What the statuses meanHow checks are countedWhy we checkHow checks are grouped

Needs attention

  • A unit label that names no basis folds one way

    Known limitation · 1 in this library · 1 in all libraries

  • Values that exclude a carbon pool list the gases behind the total

    Known limitation · 300 in this library · 50,262 in all libraries

One category axis

Learn more
  • Every source category maps to our vocabulary

    Enforced when loaded

  • The publisher's classification is kept

    Passed

  • Every classification level has a valid parent

    Passed

  • Every product code comes with the codes above it

    Passed

  • A publisher's own classification is used only by that publisher

    Passed

  • A standard classification code has one label in every library

    Passed

Coded regions

Learn more
  • Every region is a known code

    Enforced when loaded

  • No named region is filed under a broader one

    Passed

  • Every region sits in the world hierarchy

    Passed

Canonical units

Learn more
  • Every unit is a known code

    Enforced when loaded

  • One source unit maps to one unit

    Passed

  • A unit label means the same in every library

    Passed

  • A unit label that names no basis folds one way

    Known limitation · 1 in this library · 1 in all libraries

Declared boundaries

Learn more
  • Every boundary states what it includes

    Passed

  • Boundary scope terms are known codes

    Passed

  • No two factors for the same activity partly overlap in scope

    Passed

  • Separate stages of one activity are linked as parts

    Passed

  • Every part of a factor states its boundary

    Passed

  • Every biofuel counted with its biogenic CO2 says how much

    Passed

  • No recycling credit is hidden inside a life-cycle total

    Passed

Warming potentials

Learn more
  • Methane and nitrous oxide figures match the stated GWP

    Passed

  • Every convertible value has its AR6 version

    Passed

  • CO2e totals leave out what their basis excludes

    Passed

  • Values that exclude a carbon pool list the gases behind the total

    Known limitation · 300 in this library · 50,262 in all libraries

  • Standardised figures keep every gas the publisher lists

    Passed

  • Every value states what its CO2e total includes

    Passed

  • A library with no AR6 version at all has a recorded reason

    Passed · 2 in all libraries

Parts and parents

Learn more
  • Every part links to a valid parent

    Passed

  • No factor is an unlinked part of another factor

    Passed

  • Every factor points to its top parent

    Passed · 1 in all libraries

Estimated fuel legs

Learn more
  • No fuel estimate is served where the publisher printed the supply-chain figure

    Passed

  • No supply-chain estimate is served for a fuel we deliberately left out

    Passed

  • Every fuel estimate is built only from data we may redistribute

    Passed

  • No fuel supply-chain estimate is rated above what its method allows

    Passed

  • Every fuel eligible for a supply-chain estimate is classified

    Passed

  • Every fuel supply-chain estimate still matches the figures it was computed from

    Passed

  • The text of each fuel supply-chain estimate matches its current figures

    Passed

Data quality

Learn more
  • Quality ratings fall inside their scale

    Passed

  • Every zero value is explained

    Passed

  • No default value is withheld for poor quality

    Passed

  • No implausibly high per-kilogram value is rated reliable

    Passed

  • Every quality level gives a recognised reason

    Passed

  • A zero that is only a gap in the source is withheld

    Passed

  • The library is not rated entirely on one fallback quality level

    Passed

Languages

Learn more
  • Every factor has an English name

    Passed

  • Translations match the current source text

    Passed · 310 in all libraries

  • Translations follow a corrected source text

    Passed · 4 in all libraries

  • Recorded translations survive a reload

    Passed · 5 in all libraries

  • Every served factor has a name

    Passed

  • Factors are searched on their English name where one exists

    Passed · 20 in all libraries

  • Every language with a main name also has a full name

    Passed

  • Full names are built from their parts in the same language

    Passed

  • Every text is labelled with its real language

    Passed

  • Every description is available for display and translation

    Passed

  • Every usage note is available for display and translation

    Passed

Traceable to the source

Learn more
  • Values traced to one source row agree with each other

    Passed

  • No duplicate factors are served

    Passed · 174 in all libraries

  • No factor value claims two things that cannot both be true

    Passed · 3,243 in all libraries

  • No factor value the publisher has withdrawn is still served

    Passed · 10,480 in all libraries

Other checks

  • One activity keeps one family across its units

    Passed · 9 in all libraries

  • An activity's grouping key names only the activity

    Passed · 5 in all libraries

  • A Creative Commons credit names its licence

    Passed

  • No note of ours appears in the credit or licence notice

    Passed

  • The credit line carries no terms of use

    Passed

  • Every impact assessment method is a recognised code

    Passed

  • Summed totals keep their parts' classification

    Passed

  • Every summed total has a classification when its parts do

    Passed

  • Green-electricity zeros are not rated below market-based peers

    Passed

  • An avoided credit is linked to the burden it belongs to

    Passed

  • Every value is typed as specific, generic or average

    Passed

  • The market-based value is the default

    Passed

  • Summed totals equal their parts on every gas

    Passed

  • Validity dates are the publisher's own, never guessed

    Passed

  • Quality breakdowns use their scheme's axes

    Passed

  • No battery-electric vehicle carries tailpipe emissions

    Passed

  • The text of each estimated electricity total matches its current figures

    Passed

  • Every estimated factor carries its description in each language

    Passed · 16 in all libraries

  • The text of each estimated factor matches its current figures

    Passed

  • A total built on an estimated part is marked as estimated

    Passed

  • Every estimate is built only from data we may redistribute

    Passed

  • No estimated factor is rated above the data it was built from

    Passed

  • No estimate sits beside a total of unclear scope

    Passed

  • No estimate repeats a stage the publisher's total already includes

    Passed · 2 in all libraries

  • Every factor we complete has all of its estimated parts

    Passed · 7 in all libraries

  • No estimate is served where the publisher printed the figure

    Passed · 25 in all libraries

  • We only estimate for publishers whose rule allows it

    Passed

  • Every estimated factor still matches the inputs it was computed from

    Passed

  • No estimated total competes with a published one

    Passed · 24 in all libraries

  • Every factor with a current value has a default

    Passed

  • Every factor has a value, in a library that publishes values

    Passed

  • Every tagged gas has a known GWP

    Passed

  • Every fixed group of regions lists what it covers

    Passed

  • Where both exist, the residual mix is shown before the green-tariff zero

    Passed

  • Every green-electricity zero is a market-based value

    Passed

  • Every electricity factor states its mix

    Passed

  • The newest edition of each value is the one marked current

    Passed

  • Every publisher has a rule on whether we estimate its missing parts

    Passed

  • Factor descriptions describe the factor, not the whole library

    Passed

  • Every library's licence has its rights recorded

    Passed

  • No fossil electricity mix has a zero fuel supply chain

    Passed

  • Every green-electricity zero is exactly zero and says why

    Passed

  • Green-electricity zeros cover power generation only

    Passed

  • Only a total we computed may mix GWP vintages

    Passed

  • Spend factors state their price year and basis

    Passed

  • One default value per factor and year

    Passed

  • Every value has a number, a GWP version and a reference year

    Passed

  • No factor description is too long to display in full

    Passed · 28 in all libraries

  • The library-wide answers on what a factor covers are up to date

    Passed

  • Every library-wide answer applies to at least one factor

    Passed · 3 in all libraries

  • Every excused arithmetic disagreement is stated

    Passed

  • Every reference year falls between 1960 and next year

    Passed

  • The parts of a total are never listed twice under one label

    Passed

  • Every residual mix has its green-tariff counterpart

    Passed

  • Every publisher's quality rating system is read

    Passed

  • Every factor is filed under the most specific category its source allows

    Passed · 1,852 in all libraries

  • Every factor has a category

    Passed

  • Every categorised factor has a GHG Protocol scope

    Passed · 30 in all libraries

  • Single-gas values have their AR6 version

    Passed · 5 in all libraries

  • No factor answers a question that does not arise for it

    Passed · 5 in all libraries

  • A supplier named in the source is linked to the factor

    Passed

  • A part covering the same scope as its total is linked to it

    Passed

  • A year in a factor's name matches its reference year

    Passed

How the audit works

What can I do with this data?

Restricted licence · credit the publisher

Your rights

Restricted licence · au-web-copyright-notice
Use it to calculate my own footprint
Yes, if
  • you credit the publisher
Publish my footprint results
Yes, if
  • you credit the publisher

Publisher's published terms, checked on 1 Oct 2026

"The design and content of these web pages are protected according to current copyright and trademark laws, etc., and may neither be copied, altered nor reproduced in part or in whole without written permission from Aarhus University. It is permitted, however, to read, save or print the web pages for private use. Citing from web page texts is also permitted providing that this is done in accordance with established norms, that the length and content of the citation are appropriate for its purpose and that the citation is accompanied by a proper source reference." The emission factor tables carry no licence of their own.

Credit line

Source: DCE – Danish Centre for Environment and Energy, Aarhus University. Emission factors used in the Danish national emission inventories, 2024. Normalised by open-climate.ai, https://open-climate.ai/factors/libraries/dce_denmark/ (CC BY 4.0)

Not legal advice: the publisher's terms prevail.

Full terms

How to read these answers

Coverage

Browse factors

top 0 matches

SavedUnfoldFactorRegionBoundary
Unit
VersionPublishedLoadedStatusSource
20242 Jan 20261 Oct 2026ServedSource

Methodology

How this works
  • The tables print the mass of each gas per GJ of fuel input: CO2 in kg, methane and nitrous oxide in g. They print no CO2e and name no GWP set.
  • open-climate.ai computes the CO2e: fossil CO2, plus methane times 29.8 (27.0 on a fuel whose only carbon is biogenic), plus nitrous oxide times 273, the 100-year values of the IPCC Sixth Assessment Report.
  • Values are served per kWh of fuel input, converted from per GJ at 0.0036. The energy is the net calorific value, as DCE's inventory report states for the stationary table.
  • In the stationary table an italic CO2 figure is biomass. We read that markup cell by cell: an italic figure is stored as biogenic CO2, an upright one as fossil CO2, and municipal waste, which prints both, keeps both parts. The mobile table prints fossil and biogenic CO2 in separate columns. Biogenic CO2 is kept out of the CO2e and carried as its own gas.
  • The stationary table's own notes describe three fuels: the wood factor is an average of firewood (98.7 kg CO2 per GJ), wood chips (105.6) and wood waste (99.7); municipal waste has a total CO2 factor of 93.5 kg per GJ, part of it fossil; gridded gas is a mix of fossil natural gas and biomethane. Those notes are the descriptions of the factors they name.
  • The reference year of a value is the inventory year the factors were applied to, 2024.

Data year: the inventory year the factors were applied to (2024), which the stationary-combustion file does not print. Never the date in the page footer.

What we import

  • Both greenhouse gas tables of data year 2024: 560 factors, one value each, all served. 449 come from the stationary table and 111 from the mobile table. All are for Denmark.
  • 11 mobile rows print no emission value, for example LPG in fishing or kerosene on the railways. They are not loaded, and nothing they print is lost.
  • The stationary table names its fuels in capitals (NATURAL GAS, WOOD AND SIMIL.). Factor names use the fuel names of DCE's inventory report instead (Natural gas, Wood and similar wood wastes); the printed code is kept as a search tag. Mobile names are as printed. Every factor carries its SNAP code, the European source nomenclature national inventories use (SNAP 97), as a standard classification with all its levels: sector 01, sub-sector 0101, activity 010101. A code printed with a trailing 00, such as 010100 for public power, names the sub-sector itself, so it is filed at that level and the factor repeats no sub-sector. Some codes are Danish extensions the European list does not have: the industry branches 0304 to 0320, 010510 biogas upgrading and 0811 commercial and institutional machinery. The tables are in English only, so no Danish text is loaded; German and French names and descriptions are machine translated for every factor.
  • Each mobile row also carries a letter, A or P, which the table does not explain. DCE's inventory reports do: for air traffic, P is Copenhagen Airport, modelled as one large point source, and A is the other Danish airports, modelled as area sources. The letter is kept as part of the factor's identity, and the ten air traffic factors name the airports, for example "Jet fuel - Air traffic, Dom. < 3000 ft., Copenhagen Airport (point source)". For three of the five pairs the two airports print the same values.
  • Factors are placed in the open-climate.ai category tree under fuels: 77 gaseous fossil, 180 liquid fossil (LPG included), 63 solid fossil, 218 biofuels and 22 waste-derived fuels.
  • Not imported: the air pollutants the tables also print (SO2, NOx, NMVOC, CO, NH3, particulate matter and black carbon, kept with each source row in our archive), the heavy metal, PAH and non-exhaust particle tables, and earlier data years.

The tables print combustion only. Beside each fossil fuel factor, open-climate.ai adds an estimated well-to-tank leg (the emissions of extracting, processing and transporting the fuel) and a well-to-use total, each as its own factor marked as an estimate. The leg is the published combustion factor times the ratio of well-to-tank to combustion emissions for the same fuel. Natural gas, coal and LNG take the EU average of the JEC Well-to-Tank report (version 5, for 2020); the other fossil fuels take the ratio from the UK Government's 2026 greenhouse gas conversion factors. 300 of the 560 factors get a leg, every one rated very low quality. Biofuels get no leg: the combustion value leaves out their biogenic CO2, so a multiple of it means nothing. Nor do municipal and industrial waste, whose chain belongs to the waste's first life, and fuels for which no source prints both a combustion and a well-to-tank figure: coke oven coke, fly ash and GTL. The legs and totals are restricted, like the DCE factors they are built from, and carry the same terms. DCE's own numbers are unchanged: leave out estimated factors (is_estimated) to keep them only. How the fuel legs are estimated.

Restricted. The tables carry no licence of their own. The Aarhus University website notice says its pages "may neither be copied, altered nor reproduced in part or in whole without written permission from Aarhus University", and allows reading, saving and printing for private use and citing with a proper source reference. Using the factors for your own footprint and publishing results with attribution are allowed; sharing the values with customers, embedding them in a product, and modifying or combining them need DCE's written permission, which we have asked for. Attribution: "Source: DCE – Danish Centre for Environment and Energy, Aarhus University. Emission factors used in the Danish national emission inventories, 2024." Last verified 2026-10-01.

What can I do with this data?

Credit line: Source: DCE – Danish Centre for Environment and Energy, Aarhus University. Emission factors used in the Danish national emission inventories, 2024.

au-web-copyright-notice

The design and content of these web pages are protected according to current copyright and trademark laws, etc., and may neither be copied, altered nor reproduced in part or in whole without written permission from Aarhus University. It is permitted, however, to read, save or print the web pages for private use. Citing from web page texts is also permitted providing that this is done in accordance with established norms, that the length and content of the citation are appropriate for its purpose and that the citation is accompanied by a proper source reference.

Limitations

  • These are national inventory factors, averaged per fuel and technology. A plant that measures its own fuel and emissions has better numbers.
  • DCE prints no upstream emissions. The estimated well-to-tank legs we add cover the fossil fuels at very low quality, and are in CO2e on the GWP set of their source (AR4 for the JEC ratios, AR5 for the UK ones). Biofuels, waste, coke oven coke, fly ash and GTL have none.
  • The net calorific basis is stated for the stationary table only. Applying a factor to energy billed on a gross basis overstates emissions.
  • Fly ash prints the same CO2 as coal (95.13 kg per GJ), while DCE's 2023 inventory report prints 94.51. It is loaded as printed.
  • The CO2 of some fuels is a fixed national value, while methane and nitrous oxide move with the technology: natural gas runs from 57.4 to 71.6 kg CO2e per GJ depending on the plant.
  • 553 values are rated medium quality, the rating of the Norwegian, Swedish, Finnish and German inventory factors: national averages per fuel and technology, not measured at your plant. The 7 mobile factors the table marks as Tier 1, the IPCC default method, are rated low. How quality tiers are set.
  • Industrial waste prints 46.1 kg of fossil and 47.4 kg of biogenic CO2 per GJ, the same split as municipal waste. DCE's inventory report explains why: the fuel is burnt at a single cement plant, whose own data are confidential, so the municipal waste factors stand in for it.
  • One data year is loaded. The source URLs are overwritten every January, and the 2021 and 2022 stationary tables are no longer online.

Some values differ from other sources. All of these are loaded exactly as DCE prints them. Each is a Danish national value, several of them taken from the plant data reported under the EU Emissions Trading System, so they can differ from the IPCC defaults and from other countries' inventories.

  • LPG: 64.8 kg CO2 per GJ on 28 rows, but 67.39 on the process furnaces of petroleum refineries (SNAP 010306), a value taken from the refineries' own data.
  • Natural gas: 57.1 kg CO2 per GJ on 62 rows, but 57.46 on the gas turbines of oil and gas extraction (SNAP 010504). DCE's report for data year 2023 shows the same gap (57.52 against 57.14).
  • Gasoline: 73.0 kg CO2 per GJ, 5.3% above the IPCC default of 69.3. Aviation gasoline: also 73.0, 4.3% above the IPCC default of 70.0.
  • Petroleum coke: 93.0 kg CO2 per GJ, 4.6% below the IPCC default of 97.5 and below every other library we hold.
  • Biogas: 81.9 kg of biogenic CO2 per GJ, where other libraries print 54.6 to 56.1. It is biogenic, so it is carried as its own gas and stays out of the CO2e.
  • Mineral wool plants (SNAP 030701): 40 g of nitrous oxide per GJ on all six fuels, a plant-specific value far above the usual combustion factor. DCE's report for data year 2023 printed 46.

Changelog

  • 2026-10-01: data year 2024 loaded (stationary table of 31 December 2025, mobile table of 2 January 2026).
  • 2026-10-04: SNAP codes added as a classification; the A and P letters of air traffic named as the two kinds of airport; quality rating aligned with the other Nordic inventories (medium, Tier 1 low); every factor translated into German and French; values that differ from other sources documented.
  • 2026-10-05: estimated well-to-tank legs and well-to-use totals added beside the fossil fuel combustion factors, restricted like them.

Know a newer edition?

If DCE has published an edition we do not serve yet, tell us where to find it.