Emission factor from ECCC NIR-1990-2024
Grid electricity
Alberta · Upstream of transmission and distribution losses · 2024 onwards
Each kilowatt-hour drawn from the grid from 2024 counts as 0.00189 kg CO₂e for the fuel behind the electricity lost on the network (estimated). That is the 3.3 Energy upstream part of the total for Grid electricity - Alberta.
Value from 2024 onwards
0.00189kgCO₂e/kWh
Location-based · Production mix · Biogenic CO₂ and land use excluded · GWP100 · AR5
FossilBio CH₄Land useBio CO₂GHG Protocol and IPCC inventoriesEstimatedAn estimate by open-climate.ai, not a number the publisher printed. Where an electricity publisher prints generation only, we add the grid losses and the fuel chain behind it, computed by one stated rule from the publisher's own generation value and public statistics. Learn more By open-climate.ai, not published by ECCC
- Region
- Alberta CA-AB
- Boundary
- Upstream of transmission and distribution losses
- Data quality
- LowEstimated from a model of the region
- Licence
- Open · ECCC terms
Where 0.00189 comes from
ECCC does not publish this value. open-climate.ai estimated it from ECCC's published figures and a regional model.
The total: Grid electricity - Alberta
How it was estimatedReporting this kilowatt-hour under the GHG Protocol
3.3 Energy upstream 0.00189
The fuel behind the energy lost on the way to you is Scope 3, category 3.
The factor, standardised
Every factor on open-climate.ai answers the same questions in the same words, whatever the publisher. Open any ⓘ for the definition.
Electricity › Grid electricity · Alberta · per kWh · Average
Upstream of transmission and distribution losses · Location-based · Excl. biogenic CO₂ · AR5
- BoundaryUpstream of transmission and distribution lossesUpstream (well-to-tank) of the energy a grid or network loses between generation and the point of use: extraction, refining and transport of the fuel that generated the lost energy. Learn more
- Upstream of transmission and distribution losses
- Fuel supply
- Calculation approachLocation-based uses the average grid mix where the electricity was consumed; market-based uses the supplier contract or the residual mix. The two can differ by an order of magnitude on the same kilowatt-hour, so they are never interchangeable. Learn more
- Location-based, production mix
- GWP methodWhich IPCC assessment report's warming potentials convert each gas to CO₂e, and over how many years the warming is counted (GWP100: 100 years). Learn more
- IPCC AR5, 100-year horizon
- Not on the record; set from ECCC's method notes
- CO₂e basisWhich carbon the CO₂e counts. Fossil only leaves out biogenic methane, land-use change and biogenic CO₂; excl. biogenic CO₂ counts biogenic methane but not the other two; net total counts every pool, net of removals. The same activity on two bases is two different numbers. Learn more
- Excl. biogenic CO₂FossilBio CH₄Land useBio CO₂GHG Protocol and IPCC inventories
- Not split by gas; CO₂e only
- Life cycle
- Upstream: coveredProduction: not coveredDownstream: not applicableEnd of life: not applicable
Low quality · Open licence · 2004 to now
All values
10 values, one per period back to 2004. Every one is location-based, production mix, biogenic CO₂ and land use excluded, AR5 GWP100, so the years compare directly. Tap a bar.
2024 onwards0.00189Default valueEstimated
| AppliesYears | TotalkgCO₂e/kWh |
|---|---|
| 0.00189Default valueEstimated | |
| 0.00229Estimated | |
| 0.00253Estimated | |
| 0.00256Estimated | |
| 0.00292Estimated | |
| 0.00307Estimated | |
| 0.0051Estimated | |
| 0.00697Estimated | |
| 0.0146Estimated | |
| 0.0144Estimated |
- Default: what search and the API return when you ask for nothing specific
- EstimatedComputed from other figures
What this number covers
The path of one kilowatt-hour, from the fuel to your meter. This factor counts more than one step of it; the others have factors of their own.
Fuel supply
Extracting, processing and transporting the fuel the plants burn
Included, not split outGeneration
Producing the electricity at the power plants that make up the mix
Not in this partNetwork losses
Electricity lost between the plant and your meter, which still had to be generated
Not in this partUpstream of transmission and distribution losses
Counted here0.00189Your meter
1 kWh used. The factor is per kWh measured here.
Outside this boundary
- Building the power plants
Capital goods and infrastructure sit outside every well-to-use factor, in every library.
From ECCC's inputs to a comparable factor
ECCC publishes the inputs; open-climate.ai estimated this value from them, so no printed record stands beside it.
Checks this factor passed
- Ten year windows from 2004, no gaps, no overlaps.
- Unit, region, boundary and method mapped to fixed code lists.
The total and its parts
Use a part on its own when you report its scope apart from the others. Never add a part to the total.
About this factor
Source and licence
- Value
- Estimated by open-climate.ai from this source
- Publisher
- Environment and Climate Change Canada
- Library
- ECCC NIR-1990-2024
- Published
- 14 April 2026
The values and their metadata are served in full and may be reused with credit to the publisher.
Cite this factor
Contains information licensed under the Open Government Licence – Canada. Normalised by open-climate.ai, https://open-climate.ai/factors/libraries/eccc_canada/ (CC BY 4.0). https://open-climate.ai/factors/ef-eccccanada-grid_electricity_alberta-ca_ab-kwh-transmission_distributio-cadf75e1/?v=efv1-ef276dff7a5b9fe0a73cd580f23e3a0e
Something looks wrong?
Tell us which value and why. We check it against the source and answer within a week.
Page data as of .