Emission factor from Ei

Grid electricity - Nordisk residualmix: the Nordic residual mix (Denmark, Finland, Norway, Sweden) Swedish suppliers disclosed for electricity without guarantees of origin; combustion at the plant only

Nordic area: Denmark, Finland, Norway and Sweden · Upstream fuel · 2024 onwards

Each kilowatt-hour you buy from 2024 without a green tariff or certificate behind it counts as 0.0834 kg CO₂e for the fuel supplied to the power plants (estimated).

Value from 2024 onwards

0.0834kgCO₂e/kWh

Market-based · Residual mix · Fossil only · GWP100 · AR5

FossilBio CH₄Land useBio CO₂EN 15804 GWP-fossil
2024–
Default: the latest year−11% on 2023

Estimated By open-climate.ai, not published by Ei

Region
Nordic area: Denmark, Finland, Norway and Sweden
Boundary
Upstream fuel
Data quality
Very lowEstimated from a broader region
Licence
Open · Ei terms

Where 0.0834 comes from

Estimated by open-climate.ai

Ei does not publish this value. open-climate.ai estimated it from Ei's published figures and the figure for a broader region.

How it was estimated

Reporting this kilowatt-hour under the GHG Protocol

3.3 Energy upstream 0.0834

Extracting, refining and delivering the fuel behind it happens upstream: Scope 3, category 3.

CiteAPI

The factor, standardised

Every factor on open-climate.ai answers the same questions in the same words, whatever the publisher. Open any ⓘ for the definition.

Electricity › Grid electricity · Nordic area: Denmark, Finland, Norway and Sweden · per kWh · Average

Upstream fuel · Market-based · Fossil only · AR5

Boundary
Upstream fuel
Fuel supply
Calculation approach
Market-based, residual mix
GWP method
IPCC AR5, 100-year horizon
Not on the record; set from Ei's method notes
CO₂e basis
Fossil onlyFossilBio CH₄Land useBio CO₂EN 15804 GWP-fossil
Not split by gas; CO₂e only
Life cycle
Upstream: coveredProduction: not coveredDownstream: not applicableEnd of life: not applicable

Very low quality · Open licence · 2011 to now

All values

28 values: 2 methods over 14 periods back to 2011. Tap a bar.

2024 onwards · Market-based · residual mix0.0834Default valueEstimated

kgCO₂e per kWh, by year, for market-based · residual mix. Pick a year to read it.

What this number covers

The path of one kilowatt-hour, from the fuel to your meter. Not every step on it is counted; what is left out is listed below.

  1. Fuel supply

    Extracting, processing and transporting the fuel the plants burn

    Included0.0834
  2. Your meter

    1 kWh used. The factor is per kWh measured here.

    = 0.0834

Outside this boundary

  • Burning fuel at the plants
  • Purchased electricity and heat
  • Building the power plants
  • Building the grid

open-climate.ai counts running the plants, not building them.

From Ei's inputs to a comparable factor

Ei publishes the inputs; open-climate.ai estimated this value from them, so no printed record stands beside it.

Checks this factor passed

  • Unit, region, boundary and method mapped to fixed code lists.
How we standardise every library

About this factor

Source and licence

Value
Estimated by open-climate.ai from this source
Publisher
Energimarknadsinspektionen (Ei)
Published
13 June 2025
See the source data at Ei

The values and their metadata are served in full and may be reused with credit to the publisher.

Changes: values converted from g/kWh to kg/kWh. Ei does not endorse this use.
Credit it with this lineKälla: Energimarknadsinspektionen (Ei), Nordisk residualmix 2011-2024, hämtad 2026-11-09. https://ei.se/bransch/ursprungsmarkning-av-el/residualmix/residualmixen---tidigare-ar
A plain reading of the licence, not legal advice. The licence text prevails.

Cite this factor

Källa: Energimarknadsinspektionen (Ei), Nordisk residualmix 2011-2024, hämtad 2026-11-09. https://ei.se/bransch/ursprungsmarkning-av-el/residualmix/residualmixen---tidigare-ar. Normalised by open-climate.ai, https://open-climate.ai/factors/libraries/ei_sweden/ (CC BY 4.0). https://open-climate.ai/factors/ef-eisweden-grid_electricity_nordisk-nordic_dk_fi_no_se-kwh-upstream_fuel-36f09098/?v=efv1-63fe39c225ffce85ec3db5e04cd94f14

Something looks wrong?

Tell us which value and why. We check it against the source and answer within a week.

Page data as of .