Emission factor from Electricity Info 2005-2024
Electricity - Shell Energy
United Kingdom · Generation · 2023 onwards
Value from 2023 onwards
0.111kgCO₂e/kWh
Market-based · Supplier-specific mix · Fossil only · CO₂ only
FossilBio CH₄Land useBio CO₂EN 15804 GWP-fossil- Region
- United Kingdom GB
- Boundary
- Generation
- Data quality
- MediumRated by us, not by the source
- Licence
- Open · Electricity Info terms
Where 0.111 comes from
Electricity Info prints this factor as a single figure, with no parts to add up.
Reporting this kilowatt-hour under the GHG Protocol
Scope 2 0.111
You buy the energy, so its generation is your Scope 2.
The factor, standardised
Every factor on open-climate.ai answers the same questions in the same words, whatever the publisher. Open any ⓘ for the definition.
Electricity › Grid electricity · United Kingdom · per kWh · Average
Generation · Market-based · Fossil only
- BoundaryGenerationCombustion at the generating plant for purchased energy carriers. Learn more
- Generation
- Calculation approachLocation-based uses the average grid mix where the electricity was consumed; market-based uses the supplier contract or the residual mix. The two can differ by an order of magnitude on the same kilowatt-hour, so they are never interchangeable. Learn more
- Market-based, supplier-specific mix
- GWP methodWhich IPCC assessment report's warming potentials convert each gas to CO₂e, and over how many years the warming is counted (GWP100: 100 years). Learn more
- None: the value counts CO₂ alone
- CO₂ weighs 1 in every IPCC report, so no GWP applies
- CO₂e basisWhich carbon the CO₂e counts. Fossil only leaves out biogenic methane, land-use change and biogenic CO₂; excl. biogenic CO₂ counts biogenic methane but not the other two; net total counts every pool, net of removals. The same activity on two bases is two different numbers. Learn more
- Fossil onlyFossilBio CH₄Land useBio CO₂EN 15804 GWP-fossil
- All of it is CO₂
- Life cycle
- Upstream: not coveredProduction: coveredDownstream: not applicableEnd of life: not applicable
Medium quality · Open licence · 2018 to now
All values
6 values, one per year back to 2018. Every one is market-based, supplier-specific, fossil only, so the years compare directly. Tap a bar.
2023 onwards0.111Default value
| AppliesYears | TotalkgCO₂e/kWh |
|---|---|
| 0.111Default value | |
| 0 | |
| 0 | |
| 0 | |
| 0 | |
| 0.32 |
- Default: what search and the API return when you ask for nothing specific
What this number covers
The path of one kilowatt-hour, from the fuel to your meter. Not every step on it is counted; what is left out is listed below.
Generation
Producing the electricity at the power plants that make up the mix
Included0.111Your meter
1 kWh used. The factor is per kWh measured here.
= 0.111
Outside this boundary
- Electricity lost on the network
- Producing and delivering the plants' fuel
- Building the power plants
Electricity Info counts burning fuel at the plants, not producing and delivering that fuel or building the plants.
Gases
Basis: Fossil onlyFossil carbon only: biogenic CO₂, methane from biogenic sources and land-use change are left out. Learn moreFossilBio CH₄Land useBio CO₂EN 15804 GWP-fossil
- Fossil CO₂0.111
The CO₂e counts fossil carbon only; biogenic CO₂, biogenic methane and land-use carbon are left out.
From Electricity Info's record to a comparable factor
Electricity Info publishes this factor as one record. Here is each field as printed and what open-climate.ai made of it.
About this factor
Electricity Info gives no description for this factor.
Source and licence
- Publisher
- Electricity Info (ElectricityInfo.org)
- Library
- Electricity Info 2005-2024
The values and their metadata are served in full and may be reused with credit to the publisher.
Cite this factor
Electricity Info (electricityinfo.org): Fuel Mix of UK Domestic Electricity Suppliers, disclosure years 2005-2024. Normalised by open-climate.ai, https://open-climate.ai/factors/libraries/electricity_info_uk/ (CC BY 4.0). https://open-climate.ai/factors/ef-electricityinfou-electricity_shell_energy-gb-kwh-generation-5f87454d/?v=efv1-a6432866c817f9f28b9c353e6a23e46a
Something looks wrong?
Tell us which value and why. We check it against the source and answer within a week.
Page data as of .