Value from 2025 onwards
0.258kgCO₂e/kWh
Location-based · Production mix · Net total: fossil, biogenic and land use · GWP100 · GWP vintage not stated
FossilBio CH₄Land useBio CO₂full carbon balance- Region
- Romania RO
- Boundary
- Energy, full life cycle
- Data quality
- MediumRated by us, not by the source
- Licence
- Open · CC BY 4.0
Where 0.258 comes from
Ember prints this factor as a single figure, with no parts to add up and no split by gas.
Reporting this kilowatt-hour under the GHG Protocol
Scope 2 + 3.3 Energy upstream 0.258
This one figure covers both together; no split between them is given.
You buy the energy, so its generation is your Scope 2.
What happens before the power station, from extracting the fuel to building the plant, is Scope 3, category 3.
The factor, standardised
Every factor on open-climate.ai answers the same questions in the same words, whatever the publisher. Open any ⓘ for the definition.
Electricity › Grid electricity · Romania · per kWh · Average
Energy, full life cycle · Location-based · Net total
- BoundaryEnergy, full life cycleFull life-cycle emissions of one unit of energy service (a kWh generated, or a vehicle-, passenger- or tonne-kilometre moved): extraction and delivery of the fuel or electricity, its combustion in the plant or vehicle, and the manufacture of the generating asset or vehicle itself amortized over its lifetime output. Learn more
- Energy, full life cycle
- Fuel supply, generation and capital goods
- Calculation approachLocation-based uses the average grid mix where the electricity was consumed; market-based uses the supplier contract or the residual mix. The two can differ by an order of magnitude on the same kilowatt-hour, so they are never interchangeable. Learn more
- Location-based, production mix
- GWP methodWhich IPCC assessment report's warming potentials convert each gas to CO₂e, and over how many years the warming is counted (GWP100: 100 years). Learn more
- Not stated by the publisher
- CO₂e basisWhich carbon the CO₂e counts. Fossil only leaves out biogenic methane, land-use change and biogenic CO₂; excl. biogenic CO₂ counts biogenic methane but not the other two; net total counts every pool, net of removals. The same activity on two bases is two different numbers. Learn more
- Net totalFossilBio CH₄Land useBio CO₂full carbon balance
- Not split by gas; CO₂e only
- Life cycle
- Upstream: partly coveredProduction: coveredDownstream: not applicableEnd of life: not applicable
Medium quality · Open licence · 1990 to now
All values
36 values, one per year back to 1990. Every one is location-based, production mix, net total, GWP not stated by the publisher, so the years compare directly.
2025 onwards0.258Default value
- Default: what search and the API return when you ask for nothing specific
What this number covers
The path of one kilowatt-hour, from the fuel to your meter. Not every step on it is counted; what is left out is listed below.
Fuel supply
Extracting, processing and transporting the fuel the plants burn
Included, not split outGeneration
Producing the electricity at the power plants that make up the mix
Included, not split outAlso counted
- Building the power plants
Included, not split outYour meter
1 kWh used. The factor is per kWh measured here.
= 0.258
Outside this boundary
- Electricity lost on the network
From Ember's record to a comparable factor
Ember publishes this factor as one record, and a new record every year. Here is each field as printed and what open-climate.ai made of it.
About this factor
Ember gives no description for this factor. Filed under Total generation.
Source and licence
- Publisher
- Ember
- Library
- Ember
- Record
- Total generation|ROU|2025 · source, area and year
- Published
- 3 November 2026
The values and their metadata are served in full and may be reused with credit to the publisher.
Cite this factor
Ember (2026), Yearly Electricity Data. Licensed under CC BY 4.0. Normalised by open-climate.ai, https://open-climate.ai/factors/libraries/ember/ (CC BY 4.0). https://open-climate.ai/factors/ef-ember-electricity_generation-ro-kwh-generation_lifecycle-89da7570/?v=efv1-cb9df5228c7125e33c32ed84fa0f213f
Something looks wrong?
Tell us which value and why. We check it against the source and answer within a week.
Page data as of .