Emission factor from EPA Hub 2026.01

Purchased electricity - SERC South

SERC South (eGRID) · Well-to-use · Any year

Each kilowatt-hour drawn from the grid counts as 0.446 kg CO₂e: 0.363 at the power plants, 0.0639 for the fuel supplied to the power plants (estimated) and 0.0188 for the electricity lost on the network (estimated).

Value for any year

0.446kgCO₂e/kWh

Location-based · Production mix · Fossil only · GWP100 · Mixed GWP vintages

FossilBio CH₄Land useBio CO₂EN 15804 GWP-fossil

One value, for any year

EPA Hub sets no date window, so there is no year to pick.

Reference year 2026

Estimated Summed by open-climate.ai from 3 parts, 2 of them estimated by us

Region
SERC South (eGRID) US-SRSO
Boundary
Well-to-use
Data quality
HighRated by us, not by the source
Licence
Open · CC BY 4.0

Where 0.446 comes from

  • Scope 20.36381.4%
  • Fuel supplyEstimatedDerived by open-climate.ai
    3.3 Energy upstream0.063914.3%
  • Network lossesEstimatedDerived by open-climate.ai
    3.3 Energy upstream0.01884.2%
Derived by open-climate.ai

Σ 0.446: open-climate.ai adds up the three parts. EPA Hub prints generation. open-climate.ai estimates fuel supply and network losses from other published figures.

Reporting this kilowatt-hour under the GHG Protocol

Scope 2 0.363 3.3 Energy upstream 0.0827

You buy the energy, so its generation is your Scope 2.

The fuel behind it and the energy lost on the way to you are Scope 3, category 3.

CiteAPI

The factor, standardised

Every factor on open-climate.ai answers the same questions in the same words, whatever the publisher. Open any ⓘ for the definition.

Electricity › Grid electricity · SERC South (eGRID) · per kWh · Average

Well-to-use · Location-based · Fossil only

Boundary
Well-to-use
Fuel supply, generation and network losses
Calculation approach
Location-based, production mix
GWP method
Mixed IPCC reports, 100-year horizon
Not on the record; set from EPA Hub's method notes
CO₂e basis
Fossil onlyFossilBio CH₄Land useBio CO₂EN 15804 GWP-fossil
Not split by gas; CO₂e only
Life cycle
Upstream: coveredProduction: coveredDownstream: not applicableEnd of life: not applicable

High quality · Open licence · Any year

What this number covers

The path of one kilowatt-hour, from the fuel to your meter. Every step on it is counted.

  1. Fuel supply

    Extracting, processing and transporting the fuel the plants burn

    Included3.3 Energy upstream0.0639
  2. Generation

    Producing the electricity at the power plants that make up the mix

    IncludedScope 20.363
  3. Network losses

    Electricity lost between the plant and your meter, which still had to be generated

    Included3.3 Energy upstream0.0188
  4. Your meter

    1 kWh used. The factor is per kWh measured here.

    = 0.446

Outside this boundary

  • Building the power plants
  • Building the grid

Capital goods and infrastructure sit outside every well-to-use factor, in every library.

Gases

EPA Hub publishes this factor as CO₂e only, with no split by gas. The CO₂e counts fossil carbon only; biogenic CO₂, biogenic methane and land-use carbon are left out.

From EPA Hub's record to a comparable factor

EPA Hub publishes one of the three parts; open-climate.ai estimated the others and added them all up to this total. Here is each field as printed and what open-climate.ai made of it.

The total and its parts

Each part has its own page. Use a part on its own when you report Scope 2 and Scope 3 separately; never add a part to the total.

You are here · the totalPurchased electricity, SERC South, well-to-use0.446

About this factor

Source and licence

Value
Summed by open-climate.ai from its parts
Publisher
U.S. EPA GHG Emission Factors Hub (Cornerstone Sustainability Data Initiative)
Published
26 May 2026
See the source data at EPA Hub

The values and their metadata are served in full and may be reused with credit to the publisher.

Credit it with this lineEmission factors: U.S. EPA GHG Emission Factors Hub (2026 edition), published by the Cornerstone Sustainability Data Initiative, CC BY 4.0. Underlying data is public-domain U.S. EPA.
A plain reading of the licence, not legal advice. The licence text prevails.

Cite this factor

Emission factors: U.S. EPA GHG Emission Factors Hub (2026 edition), published by the Cornerstone Sustainability Data Initiative, CC BY 4.0. Underlying data is public-domain U.S. EPA. Normalised by open-climate.ai, https://open-climate.ai/factors/libraries/epa/ (CC BY 4.0). https://open-climate.ai/factors/ef-epa-purchased_electricity-us_srso-kwh-well_to_use-7200c968/?v=efv1-9682ed80a4b56ca3aa30e98a19fec594

Something looks wrong?

Tell us which value and why. We check it against the source and answer within a week.

Page data as of .