Emission factor from EPA Hub 2026.01
Purchased electricity - SERC South
SERC South (eGRID) · Well-to-use · Any year
Each kilowatt-hour drawn from the grid counts as 0.446 kg CO₂e: 0.363 at the power plants, 0.0639 for the fuel supplied to the power plants (estimated) and 0.0188 for the electricity lost on the network (estimated).
Value for any year
0.446kgCO₂e/kWh
Location-based · Production mix · Fossil only · GWP100 · Mixed GWP vintages
FossilBio CH₄Land useBio CO₂EN 15804 GWP-fossilOne value, for any year
EPA Hub sets no date window, so there is no year to pick.
Reference year 2026
EstimatedAn estimate by open-climate.ai, not a number the publisher printed. Where an electricity publisher prints generation only, we add the grid losses and the fuel chain behind it, computed by one stated rule from the publisher's own generation value and public statistics. Learn more Summed by open-climate.ai from 3 parts, 2 of them estimated by us
- Region
- SERC South (eGRID) US-SRSO
- Boundary
- Well-to-use
- Data quality
- HighRated by us, not by the source
- Licence
- Open · CC BY 4.0
Where 0.446 comes from
- Scope 20.36381.4%
- Fuel supplyEstimatedAn estimate by open-climate.ai, not a number the publisher printed. Where an electricity publisher prints generation only, we add the grid losses and the fuel chain behind it, computed by one stated rule from the publisher's own generation value and public statistics. Learn moreDerived by open-climate.ai3.3 Energy upstream0.063914.3%
- Network lossesEstimatedAn estimate by open-climate.ai, not a number the publisher printed. Where an electricity publisher prints generation only, we add the grid losses and the fuel chain behind it, computed by one stated rule from the publisher's own generation value and public statistics. Learn moreDerived by open-climate.ai3.3 Energy upstream0.01884.2%
Σ 0.446: open-climate.ai adds up the three parts. EPA Hub prints generation. open-climate.ai estimates fuel supply and network losses from other published figures.
Reporting this kilowatt-hour under the GHG Protocol
Scope 2 0.363 3.3 Energy upstream 0.0827
You buy the energy, so its generation is your Scope 2.
The fuel behind it and the energy lost on the way to you are Scope 3, category 3.
The factor, standardised
Every factor on open-climate.ai answers the same questions in the same words, whatever the publisher. Open any ⓘ for the definition.
Electricity › Grid electricity · SERC South (eGRID) · per kWh · Average
Well-to-use · Location-based · Fossil only
- BoundaryWell-to-useOne unit of energy as consumed, priced from the well to the point of use: the well-to-tank chain plus the burn for a fuel; generation, its well-to-tank and the transmission and distribution losses for a delivered carrier (electricity, steam or hot water, chilled water). Learn more
- Well-to-use
- Fuel supply, generation and network losses
- Calculation approachLocation-based uses the average grid mix where the electricity was consumed; market-based uses the supplier contract or the residual mix. The two can differ by an order of magnitude on the same kilowatt-hour, so they are never interchangeable. Learn more
- Location-based, production mix
- GWP methodWhich IPCC assessment report's warming potentials convert each gas to CO₂e, and over how many years the warming is counted (GWP100: 100 years). Learn more
- Mixed IPCC reports, 100-year horizon
- Not on the record; set from EPA Hub's method notes
- CO₂e basisWhich carbon the CO₂e counts. Fossil only leaves out biogenic methane, land-use change and biogenic CO₂; excl. biogenic CO₂ counts biogenic methane but not the other two; net total counts every pool, net of removals. The same activity on two bases is two different numbers. Learn more
- Fossil onlyFossilBio CH₄Land useBio CO₂EN 15804 GWP-fossil
- Not split by gas; CO₂e only
- Life cycle
- Upstream: coveredProduction: coveredDownstream: not applicableEnd of life: not applicable
High quality · Open licence · Any year
What this number covers
The path of one kilowatt-hour, from the fuel to your meter. Every step on it is counted.
Fuel supply
Extracting, processing and transporting the fuel the plants burn
Included3.3 Energy upstream0.0639Generation
Producing the electricity at the power plants that make up the mix
IncludedScope 20.363Network losses
Electricity lost between the plant and your meter, which still had to be generated
Included3.3 Energy upstream0.0188Your meter
1 kWh used. The factor is per kWh measured here.
= 0.446
Outside this boundary
- Building the power plants
- Building the grid
Capital goods and infrastructure sit outside every well-to-use factor, in every library.
Gases
EPA Hub publishes this factor as CO₂e only, with no split by gas. The CO₂e counts fossil carbon only; biogenic CO₂, biogenic methane and land-use carbon are left out.
From EPA Hub's record to a comparable factor
EPA Hub publishes one of the three parts; open-climate.ai estimated the others and added them all up to this total. Here is each field as printed and what open-climate.ai made of it.
The total and its parts
Each part has its own page. Use a part on its own when you report Scope 2 and Scope 3 separately; never add a part to the total.
About this factor
Source and licence
- Value
- Summed by open-climate.ai from its parts
- Publisher
- U.S. EPA GHG Emission Factors Hub (Cornerstone Sustainability Data Initiative)
- Library
- EPA Hub 2026.01
- Published
- 26 May 2026
The values and their metadata are served in full and may be reused with credit to the publisher.
Cite this factor
Emission factors: U.S. EPA GHG Emission Factors Hub (2026 edition), published by the Cornerstone Sustainability Data Initiative, CC BY 4.0. Underlying data is public-domain U.S. EPA. Normalised by open-climate.ai, https://open-climate.ai/factors/libraries/epa/ (CC BY 4.0). https://open-climate.ai/factors/ef-epa-purchased_electricity-us_srso-kwh-well_to_use-7200c968/?v=efv1-9682ed80a4b56ca3aa30e98a19fec594
Something looks wrong?
Tell us which value and why. We check it against the source and answer within a week.
Page data as of .