Emission factor from EPD Italy EPD, product-specific
ALL.CO HT160S – anodized
Italy · EPD total · Reference year 2025
Each kilogram of this product counts as 9.4 kg CO₂e over the modules its EPD declares: 9.19 to make it (A1–A3) and 0.213 at end of life.
Value per kilogram, over the modules the EPD declares
9.4kgCO₂e/kg
EN 15804 modules A1 to A3 · Fossil only · GWP100 · AR5
Derived by open-climate.ai: the sum of EPD Italy's published parts
The one scenario this EPD declaresReference year 2025
- Region
- Italy IT
- Boundary
- EPD total
- Data quality
- HighRated by us, not by the source
- Licence
- Open · EPD Italy terms
- Declared by
- ALL.CO S.p.A.
Where 9.4 comes from
- A1-A3 Product stageDerived by open-climate.aiScope 3, cat. 19.1997.7%
- End of lifeDerived by open-climate.aiScope 3, cat. 50.2132.3%
- Outside the scopes−2.79beside
Σ 9.4: the two declared modules add up to the total. D stays beside it.
Reporting this kilogram under the GHG Protocol
This period
Scope 3, category 1 9.19
You buy the product for a building that is not yours. The product and its installation go to category 1, the delivery to category 4. The use stage belongs to the building owner; demolition waste you handle is category 5.
Later, when it happens
At end of life, in the year of demolition
- End of life Scope 3, category 5 0.213
Outside the scopes, reported separately
- D −2.79
A4, A5, B1 to B7 and C1 to C4 are not declared: nothing to report.
The factor, standardised
Every factor on open-climate.ai answers the same questions in the same words, whatever the publisher. Open any ⓘ for the definition.
Materials › Metals · Italy · per kg · Supplier-specific
EPD total · Fossil only · AR5
- BoundaryEPD totalThe sum of every EN 15804 module an EPD declares, when that set is not the complete A-C grid (MOD-0034). Learn more
- EPD total
- Raw materials, inbound transport, fuel supply, fuel combustion, manufacturing, packaging, purchased energy and end of life
- GWP methodWhich IPCC assessment report's warming potentials convert each gas to CO₂e, and over how many years the warming is counted (GWP100: 100 years). Learn more
- IPCC AR5, 100-year horizon
- Not on the record; set from EPD Italy's method notes · impact method EF 3.0
- CO₂e basisWhich carbon the CO₂e counts. Fossil only leaves out biogenic CO₂ and land use; net total counts every pool, net of removals. The same activity on two bases is two different numbers. Learn more
- Fossil only
- Split by carbon origin, not by gas
- Life cycle
- Upstream: coveredProduction: coveredDownstream: not coveredEnd of life: partly covered
High quality · Open licence · Any year
Module by module, up to the total
Seventeen EN 15804 modules, always in the same order. Each declared one moves the running total. D sits below zero after the total, because it is reported beside it.
beside the total, not in it
| Module | Name | Per kilogram | Running total | Status |
|---|---|---|---|---|
| A1 | Raw material supply | 8.76 | 8.76 | Declared |
| A2 | Transport to the plant | 0.086 | 8.846 | Declared |
| A3 | Manufacturing | 0.343 | 9.189 | Declared |
| A4 | Transport to site | not declared | 9.189 | Not declared |
| A5 | Installation | not declared | 9.189 | Not declared |
| B1 | Use | not declared | 9.189 | Not declared |
| B2 | Maintenance | not declared | 9.189 | Not declared |
| B3 | Repair | not declared | 9.189 | Not declared |
| B4 | Replacement | not declared | 9.189 | Not declared |
| B5 | Refurbishment | not declared | 9.189 | Not declared |
| B6 | Energy in use | not declared | 9.189 | Not declared |
| B7 | Water in use | not declared | 9.189 | Not declared |
| C1 | Demolition | not declared | 9.189 | Not declared |
| C2 | Waste transport | 0.00879 | 9.19779 | Declared |
| C3 | Waste processing | 0.203 | 9.40079 | Declared |
| C4 | Disposal | 0.00133 | 9.40212 | Declared |
| Total | EPD total, declared modules | 9.40212 | Sum of the declared modules | |
| D | Beyond the system boundary | −2.79 | not added | Beside the total, not in it |
What this number covers
Follow one kilogram of this product through EN 15804's stages. The total counts what the EPD declares; what it leaves out stays visible.
A1-A3Product
Materials and making the product
Included9.19A4-A5Construction
Delivery and installation
Not declaredB1-B7Use
The product in service: maintenance, repair, replacement and the energy and water it uses
Not declaredC1-C4End of life
Waste transport to disposal; C1 not declared
C2 to C40.213DBeyond the boundary
Recovery after end of life
Not in the total−2.79
Outside this boundary
- Installation
- Maintenance
- Outbound transport
- Retail
- Use phase
- Recycling credit
Maintenance is out because B2 is not declared. The recycling credit is module D, shown beside the total.
Gases
- Fossil CO₂e9.4
- Biogenic CO₂e0.0527
- Land-use CO₂e0.00488
The total counts fossil CO₂e. EPD Italy reports biogenic and land-use CO₂e separately; they are shown beside it, not added.
From EPD Italy's record to a comparable factor
EPD Italy publishes this EPD as one declared value. Each field as printed, and what open-climate.ai made of it.
The total and its modules
Use a module on its own when you report it in a different year or scope; never add one to the total.
About this factor
From EPD Italy
What it is
1 kg of aluminium profile The validity period of the Managed LCA Content database used is between 2018 and 2023. Most of the information (use of raw materials, energy and water consumption, pollutant emissions and dust production) is measured or calculated directly at company level and declared in the official company documentation. The overall quality of the data can be considered good. "The allocation criteria are based on mass and comply with the provisions of standard EN 15804+A2: · foundry data is based on an annual average allocated to total production; · total annual energy consumption has been allocated considering the different production areas; · for painting, annual average data has been used and the allocation has been based on primary aluminium input; · for extrusion and thermal cutting, specific data relating to billets were used, while all other flows were considered as annual averages; · specific billet data were used for extrusion and thermal breaking, while all other flows were considered as annual averages; · for the extrusion process, all data are allocated to the extruded profiles produced, while the auxiliaries are allocated to the incoming billets." "All processes involved in production were taken into account in the study. These include the production of raw materials, electricity and the direct generation of waste from production. In addition, all material and energy flows (even those with a share of less than 1% of the total mass/energy) were considered. It can be concluded that the total sum of neglected material streams does not exceed 5% of mass, energy or environmental relevance. The impacts generated by machinery and infrastructures (in compliance with the ISO14040/44 standard) have been excluded from the boundaries of the system."What it includes
"Fixed frame section: 160 mm Sash cross-section: 70 mm Glass seat height: 24 mm Thermal transmittance of the profiles (Uf): 2.6÷ 7.4 W/m²K Air permeability: 600 Pa Water tightness: Up to 1050 Pa Wind resistance: Up to 2000 Pa Noise isolation: Up to 38 dB"Where it applies
"The profiles of the HT160S ALL.CO series are made by extrusion in aluminum alloy EN AW 6060 (UNI EN 573-3 and UNI EN 755-2) with supply status T6 (UNI EN 515), with thicknesses and dimensional tolerances in accordance with the UNI EN 12020-2 standard. The thermal break of the profiles is obtained by means of 30/32 mm bars in low lambda polyamide PA66GF25 reinforced with 25% glass fibers. The assembly of the latter with the aluminium profiles is carried out by computerised mechanical rolling to ensure a sliding resistance of more than 2.4 daN/mm. Assembly is done by means of 45° cuts and joints. The fixed frame has a depth of 160 mm, two-way track, while the movable sash has a depth of 70 mm. The middle knot has a width of 105 mm, while the side knot has a width of 129.3 mm. The assembly of the profiles takes place by means of push-button die-cast aluminium brackets. The protection and finishing of aluminium profiles can be carried out by anodizing with a minimum thickness of 15 microns (UNI 10681), or by powder coating with thermosetting polyesters cured in an oven at a temperature between 185 °C and 195 °C with a maximum residence time of 20 minutes. Application area: Thermal break aluminium profiles applied in the building sector. " ALL.CO HT160S – mill-finished ALL.CO HT160S – painted ALL.CO HT160S– anodizedSource and licence
- Value
- Summed by open-climate.ai from its parts
- Publisher
- EPD Italy (ICMQ)
- Published
- 2 October 2026
- Valid until
- 31 December 2030
The values and their metadata are served in full and may be reused with credit to the publisher.
Cite this factor
EPD Italy (ICMQ), EPD data from https://epditaly.lca-data.com. Normalised by open-climate.ai, https://open-climate.ai/factors/libraries/epd_italy/ (CC BY 4.0). https://open-climate.ai/factors/ef-epditaly-allco_ht160s_anodized-it-kg-epd_total-89941d64/?v=efv1-6f9cbb7285e8ef285a3314f38bd21ec8
Something looks wrong?
Tell us which value and why. We check it against the source and answer within a week.