Emission factor from EPD Italy EPD, product-specific
Painted Aluminium Coil (0.46-3003)
China · EPD total · Reference year 2025
Each kilogram of this product counts as 16.2 kg CO₂e over the modules its EPD declares: 14.9 to make it (A1–A3) and 1.24 at end of life.
Value per kilogram, over the modules the EPD declares
16.2kgCO₂e/kg
EN 15804 modules A1 to A3 · Fossil only · GWP100 · AR5
Derived by open-climate.ai: the sum of EPD Italy's published parts
The one scenario this EPD declaresReference year 2025
- Region
- China CN
- Boundary
- EPD total
- Data quality
- HighRated by us, not by the source
- Licence
- Open · EPD Italy terms
- Declared by
- Jiangsu Lidao New Material Co., LTD.
Where 16.2 comes from
- A1-A3 Product stageDerived by open-climate.aiScope 3, cat. 114.992.4%
- End of lifeDerived by open-climate.aiScope 3, cat. 51.247.6%
- Outside the scopes−4.52beside
Σ 16.2: the two declared modules add up to the total. D stays beside it.
Reporting this kilogram under the GHG Protocol
This period
Scope 3, category 1 14.9
You buy the product for a building that is not yours. The product and its installation go to category 1, the delivery to category 4. The use stage belongs to the building owner; demolition waste you handle is category 5.
Later, when it happens
At end of life, in the year of demolition
- End of life Scope 3, category 5 1.24
Outside the scopes, reported separately
- D −4.52
A4, A5, B1 to B7 and C1 to C4 are not declared: nothing to report.
The factor, standardised
Every factor on open-climate.ai answers the same questions in the same words, whatever the publisher. Open any ⓘ for the definition.
Materials › Metals · China · per kg · Supplier-specific
EPD total · Fossil only · AR5
- BoundaryEPD totalThe sum of every EN 15804 module an EPD declares, when that set is not the complete A-C grid (MOD-0034). Learn more
- EPD total
- Raw materials, inbound transport, fuel supply, fuel combustion, manufacturing, packaging, purchased energy and end of life
- GWP methodWhich IPCC assessment report's warming potentials convert each gas to CO₂e, and over how many years the warming is counted (GWP100: 100 years). Learn more
- IPCC AR5, 100-year horizon
- Not on the record; set from EPD Italy's method notes · impact method EF 3.0
- CO₂e basisWhich carbon the CO₂e counts. Fossil only leaves out biogenic CO₂ and land use; net total counts every pool, net of removals. The same activity on two bases is two different numbers. Learn more
- Fossil only
- Split by carbon origin, not by gas
- Life cycle
- Upstream: coveredProduction: coveredDownstream: not coveredEnd of life: partly covered
High quality · Open licence · Any year
Module by module, up to the total
Seventeen EN 15804 modules, always in the same order. Each declared one moves the running total. D sits below zero after the total, because it is reported beside it.
beside the total, not in it
| Module | Name | Per kilogram | Running total | Status |
|---|---|---|---|---|
| A1 | Raw material supply | 14.5772 | 14.5772 | Declared |
| A2 | Transport to the plant | 0.0319046 | 14.6091 | Declared |
| A3 | Manufacturing | 0.337541 | 14.9466 | Declared |
| A4 | Transport to site | not declared | 14.9466 | Not declared |
| A5 | Installation | not declared | 14.9466 | Not declared |
| B1 | Use | not declared | 14.9466 | Not declared |
| B2 | Maintenance | not declared | 14.9466 | Not declared |
| B3 | Repair | not declared | 14.9466 | Not declared |
| B4 | Replacement | not declared | 14.9466 | Not declared |
| B5 | Refurbishment | not declared | 14.9466 | Not declared |
| B6 | Energy in use | not declared | 14.9466 | Not declared |
| B7 | Water in use | not declared | 14.9466 | Not declared |
| C1 | Demolition | 1.07379 | 16.0204 | Declared |
| C2 | Waste transport | 0.00958264 | 16.03 | Declared |
| C3 | Waste processing | 0.146112 | 16.1761 | Declared |
| C4 | Disposal | 0.00552847 | 16.1816 | Declared |
| Total | EPD total, declared modules | 16.1816 | Sum of the declared modules | |
| D | Beyond the system boundary | −4.51624 | not added | Beside the total, not in it |
What this number covers
Follow one kilogram of this product through EN 15804's stages. The total counts what the EPD declares; what it leaves out stays visible.
A1-A3Product
Materials and making the product
Included14.9A4-A5Construction
Delivery and installation
Not declaredB1-B7Use
The product in service: maintenance, repair, replacement and the energy and water it uses
Not declaredC1-C4End of life
From demolition to disposal
Included1.24DBeyond the boundary
Recovery after end of life
Not in the total−4.52
Outside this boundary
- Installation
- Maintenance
- Outbound transport
- Retail
- Use phase
- Recycling credit
Maintenance is out because B2 is not declared. The recycling credit is module D, shown beside the total.
Gases
- Fossil CO₂e16.2
- Biogenic CO₂e0.0263
- Land-use CO₂e0.141
The total counts fossil CO₂e. EPD Italy reports biogenic and land-use CO₂e separately; they are shown beside it, not added.
From EPD Italy's record to a comparable factor
EPD Italy publishes this EPD as one declared value. Each field as printed, and what open-climate.ai made of it.
The total and its modules
Use a module on its own when you report it in a different year or scope; never add one to the total.
About this factor
From EPD Italy
What it is
1kg product Geographical representativeness and technical representativeness mostly are good, and time representativeness is very good. the physical relationship (yield) is adopted to allocate electricity, photovoltaic power, water, natural gas and diesel. "All inputs and outputs to a (unit) process shall be included in the calculation, for which data are available. Data gaps may be filled by conservative assumptions with average or generic data. Any assumptions for such choices shall be documented; — In case of insufficient input data or data gaps for a unit process, the cut-off criteria shall be 1 % of renewable and non-renewable primary energy usage and 1 % of the total mass input of that unit process. The total of neglected input flows per module, e.g. per module A1-A3, A4-A5, B1-B5, B6-B7, C1-C4 and module D shall be a maximum of 5 % of energy usage and mass. Conservative assumptions in combination with plausibility considerations and expert judgement can be used to demonstrate compliance with these criteria; — Particular care should be taken to include material and energy flows known to have the potential to cause significant emissions into air and water or soil related to the environmental indicators of this standard. Conservative assumptions in combination with plausibility considerations and expert judgement can be used to demonstrate compliance with these criteria.According to the above cut-off principle, this study ignored the environment impact of infrastructure such as roads and factories, production equipment, personnel and living facilities in the plant."What it includes
Painted Aluminium Coil (3.0-5052) Painted Aluminium Coil (1.5-3003) Painted Aluminium Coil (1.2-3004) Painted Aluminium Coil (0.98-3003) Painted Aluminium Coil (0.9-3004) Painted Aluminium Coil (0.7-5005) Painted Aluminium Coil (0.6-5052) Painted Aluminium Coil (0.46-3003) Painted Aluminium Coil (0.38-3003) Painted Aluminium Coil (1.0-3003)Where it applies
The Painted Aluminium Coil for Construction is a high - performance material designed for building applications, offering durability, weather - resistance, excellent formation capabilities. Products can be used in industries such as construction, household appliances, and transportation. The technical standards and performance index requirements can be referred to YS/T 431—2009 Aluminium and aluminium alloys—Coil coated sheet and strip. The identification name is determined by the thickness of aluminium coils (cm) and the alloy grade utilized in the product manufacturing process.Source and licence
- Value
- Summed by open-climate.ai from its parts
- Publisher
- EPD Italy (ICMQ)
- Published
- 2 October 2026
- Valid until
- 31 December 2030
The values and their metadata are served in full and may be reused with credit to the publisher.
Cite this factor
EPD Italy (ICMQ), EPD data from https://epditaly.lca-data.com. Normalised by open-climate.ai, https://open-climate.ai/factors/libraries/epd_italy/ (CC BY 4.0). https://open-climate.ai/factors/ef-epditaly-painted_aluminium_coil-cn-kg-epd_total-2ea72278/?v=efv1-cdca6254a57b9f1952ccfc5dce79df00
Something looks wrong?
Tell us which value and why. We check it against the source and answer within a week.