Emission factor from ICM 2019
Electricity, high voltage, New South Wales
Australia · Energy, full life cycle · Any year
Each kilowatt-hour drawn from the grid counts as 1.05 kg CO₂e: 1.02 for process LCA (AusLCI) and 0.0288 for input-output supplement (services, capital, machinery).
Value for any year
1.05kgCO₂e/kWh
Location-based · Production mix · Biogenic CO₂ and land use excluded · GWP100 · AR4
FossilBio CH₄Land useBio CO₂GHG Protocol and IPCC inventoriesOne value, for any year
ICM sets no date window, so there is no year to pick.
Reference year 2015
- Region
- Australia AU
- Boundary
- Energy, full life cycle
- Data quality
- MediumRated by us, not by the source
- Licence
- Open · CC BY 4.0
Where 1.05 comes from
- Process LCA (AusLCI)Energy, full life cycleScope 2 3.3 Energy upstream1.0297.3%
- Input-output supplement (services, capital, machinery)Derived by open-climate.aiOther stages3.3 Energy upstream0.02882.7%
Σ 1.05: the two parts add up to ICM's published total.
Reporting this kilowatt-hour under the GHG Protocol
Scope 2 + 3.3 Energy upstream 1.02 3.3 Energy upstream 0.0288
This one figure covers both together; no split between them is given.
You buy the energy, so its generation is your Scope 2.
The fuel behind it and the energy lost on the way to you are Scope 3, category 3.
The factor, standardised
Every factor on open-climate.ai answers the same questions in the same words, whatever the publisher. Open any ⓘ for the definition.
Electricity › Grid electricity · Australia · per kWh · Average
Energy, full life cycle · Location-based · Excl. biogenic CO₂ · AR4
- BoundaryEnergy, full life cycleFull life-cycle emissions of one unit of energy service (a kWh generated, or a vehicle-, passenger- or tonne-kilometre moved): extraction and delivery of the fuel or electricity, its combustion in the plant or vehicle, and the manufacture of the generating asset or vehicle itself amortized over its lifetime output. Learn more
- Energy, full life cycle
- Fuel supply, generation, network losses, capital goods and overheads and services
- Calculation approachLocation-based uses the average grid mix where the electricity was consumed; market-based uses the supplier contract or the residual mix. The two can differ by an order of magnitude on the same kilowatt-hour, so they are never interchangeable. Learn more
- Location-based, production mix
- GWP methodWhich IPCC assessment report's warming potentials convert each gas to CO₂e, and over how many years the warming is counted (GWP100: 100 years). Learn more
- IPCC AR4, 100-year horizon
- Not on the record; inferred by open-climate.ai
- CO₂e basisWhich carbon the CO₂e counts. Fossil only leaves out biogenic methane, land-use change and biogenic CO₂; excl. biogenic CO₂ counts biogenic methane but not the other two; net total counts every pool, net of removals. The same activity on two bases is two different numbers. Learn more
- Excl. biogenic CO₂FossilBio CH₄Land useBio CO₂GHG Protocol and IPCC inventories
- Not split by gas; CO₂e only
- Life cycle
- Upstream: coveredProduction: coveredDownstream: not applicableEnd of life: not applicable
Medium quality · Open licence · Any year
What this number covers
The path of one kilowatt-hour, from the fuel to your meter. Every step on it is counted.
Process LCA (AusLCI)
IncludedScope 21.02Input-output supplement (services, capital, machinery)
Included3.3 Energy upstream0.0288Your meter
1 kWh used. The factor is per kWh measured here.
= 1.05
Gases
ICM publishes this factor as CO₂e only, with no split by gas. The CO₂e leaves biogenic CO₂ and land-use carbon out; methane from biogenic sources is counted.
From ICM's record to a comparable factor
ICM publishes this factor as one record with two sub-lines. Here is each field as printed and what open-climate.ai made of it.
The total and its parts
Each part has its own page, with its own years and source record. Use a part on its own when you report Scope 2 and Scope 3 separately; never add a part to the total.
About this factor
ICM gives no description for this factor.
Source and licence
- Publisher
- UNSW Sydney, Integrated Carbon Metrics (ICM) Database
- Library
- ICM 2019
- Record
- 303
The values and their metadata are served in full and may be reused with credit to the publisher.
Cite this factor
Wiedmann, T., Teh, S. H. and Yu, M. (2019) ICM Database - Integrated Carbon Metrics Embodied Carbon Life Cycle Inventory Database, UNSW Sydney. CC BY 4.0, https://creativecommons.org/licenses/by/4.0/. Normalised by open-climate.ai, https://open-climate.ai/factors/libraries/icm/ (CC BY 4.0). https://open-climate.ai/factors/ef-icm-electricity_high_voltage-au-kwh-energy_lifecycle-d5f788b2/?v=efv1-6596863affc77d5f534fd6b747c96666
Something looks wrong?
Tell us which value and why. We check it against the source and answer within a week.
Page data as of .