Emission factor from ICM 2019

Electricity, high voltage, New South Wales

Australia · Energy, full life cycle · Any year

Each kilowatt-hour drawn from the grid counts as 1.05 kg CO₂e: 1.02 for process LCA (AusLCI) and 0.0288 for input-output supplement (services, capital, machinery).

Value for any year

1.05kgCO₂e/kWh

Location-based · Production mix · Biogenic CO₂ and land use excluded · GWP100 · AR4

FossilBio CH₄Land useBio CO₂GHG Protocol and IPCC inventories

One value, for any year

ICM sets no date window, so there is no year to pick.

Reference year 2015

Region
Australia AU
Boundary
Energy, full life cycle
Data quality
MediumRated by us, not by the source
Licence
Open · CC BY 4.0

Where 1.05 comes from

Σ 1.05: the two parts add up to ICM's published total.

Reporting this kilowatt-hour under the GHG Protocol

Scope 2 + 3.3 Energy upstream 1.02 3.3 Energy upstream 0.0288

This one figure covers both together; no split between them is given.

You buy the energy, so its generation is your Scope 2.

The fuel behind it and the energy lost on the way to you are Scope 3, category 3.

CiteAPI

The factor, standardised

Every factor on open-climate.ai answers the same questions in the same words, whatever the publisher. Open any ⓘ for the definition.

Electricity › Grid electricity · Australia · per kWh · Average

Energy, full life cycle · Location-based · Excl. biogenic CO₂ · AR4

Boundary
Energy, full life cycle
Fuel supply, generation, network losses, capital goods and overheads and services
Calculation approach
Location-based, production mix
GWP method
IPCC AR4, 100-year horizon
Not on the record; inferred by open-climate.ai
CO₂e basis
Excl. biogenic CO₂FossilBio CH₄Land useBio CO₂GHG Protocol and IPCC inventories
Not split by gas; CO₂e only
Life cycle
Upstream: coveredProduction: coveredDownstream: not applicableEnd of life: not applicable

Medium quality · Open licence · Any year

What this number covers

The path of one kilowatt-hour, from the fuel to your meter. Every step on it is counted.

  1. Process LCA (AusLCI)

    IncludedScope 21.02
  2. Input-output supplement (services, capital, machinery)

    Included3.3 Energy upstream0.0288
  3. Your meter

    1 kWh used. The factor is per kWh measured here.

    = 1.05

Gases

ICM publishes this factor as CO₂e only, with no split by gas. The CO₂e leaves biogenic CO₂ and land-use carbon out; methane from biogenic sources is counted.

From ICM's record to a comparable factor

ICM publishes this factor as one record with two sub-lines. Here is each field as printed and what open-climate.ai made of it.

The total and its parts

Each part has its own page, with its own years and source record. Use a part on its own when you report Scope 2 and Scope 3 separately; never add a part to the total.

You are here · the totalElectricity, high voltage, New South Wales, energy, full life cycle1.05

About this factor

ICM gives no description for this factor.

Source and licence

Publisher
UNSW Sydney, Integrated Carbon Metrics (ICM) Database
Library
ICM 2019
Record
303

The values and their metadata are served in full and may be reused with credit to the publisher.

Credit it with this lineWiedmann, T., Teh, S. H. and Yu, M. (2019) ICM Database - Integrated Carbon Metrics Embodied Carbon Life Cycle Inventory Database, UNSW Sydney. CC BY 4.0, https://creativecommons.org/licenses/by/4.0/
A plain reading of the licence, not legal advice. The licence text prevails.

Cite this factor

Wiedmann, T., Teh, S. H. and Yu, M. (2019) ICM Database - Integrated Carbon Metrics Embodied Carbon Life Cycle Inventory Database, UNSW Sydney. CC BY 4.0, https://creativecommons.org/licenses/by/4.0/. Normalised by open-climate.ai, https://open-climate.ai/factors/libraries/icm/ (CC BY 4.0). https://open-climate.ai/factors/ef-icm-electricity_high_voltage-au-kwh-energy_lifecycle-d5f788b2/?v=efv1-6596863affc77d5f534fd6b747c96666

Something looks wrong?

Tell us which value and why. We check it against the source and answer within a week.

Page data as of .