Each kilowatt-hour you buy without a green tariff or certificate behind it counts as 0.9 kg CO₂e: 0.79 at the power plants and 0.11 for the fuel supplied to the power plants.

Value for any year

0.9kgCO₂e/kWh

Market-based · Residual mix · Biogenic CO₂ and land use excluded · GWP100 · AR5

FossilBio CH₄Land useBio CO₂GHG Protocol and IPCC inventories

One value, for any year

NGA sets no date window, so there is no year to pick.

Reference year 2025

Derived by open-climate.ai: the sum of NGA's published parts

Australia: every library's grid factor, side by side

Region
Australia AU
Boundary
Well-to-use
Data quality
HighRated by us, not by the source
Licence
Open · CC BY 4.0

Where 0.9 comes from

Derived by open-climate.ai

Σ 0.9: NGA prints the two parts separately; open-climate.ai adds them up.

Reporting this kilowatt-hour under the GHG Protocol

Scope 2 0.79 3.3 Energy upstream 0.11

You buy the energy, so its generation is your Scope 2.

Extracting, refining and delivering the fuel behind it happens upstream: Scope 3, category 3.

CiteAPI

The factor, standardised

Every factor on open-climate.ai answers the same questions in the same words, whatever the publisher. Open any ⓘ for the definition.

Electricity › Grid electricity · Australia · per kWh · Average

Well-to-use · Market-based · Excl. biogenic CO₂ · AR5

Boundary
Well-to-use
Fuel supply, generation and network losses
Calculation approach
Market-based, residual mix
GWP method
IPCC AR5, 100-year horizon
Not on the record; inferred by open-climate.ai
CO₂e basis
Excl. biogenic CO₂FossilBio CH₄Land useBio CO₂GHG Protocol and IPCC inventories
Not split by gas; CO₂e only
Life cycle
Upstream: coveredProduction: coveredDownstream: not applicableEnd of life: not applicable

High quality · Open licence · Any year

What this number covers

The path of one kilowatt-hour, from the fuel to your meter. Every step on it is counted.

  1. Fuel supply

    Extracting, processing and transporting the fuel the plants burn

    Included3.3 Energy upstream0.11
  2. Generation

    Producing the electricity at the power plants that make up the mix

    IncludedScope 20.79
  3. Your meter

    1 kWh used. The factor is per kWh measured here.

    = 0.9

Outside this boundary

  • Building the power plants
  • Building the grid

Capital goods and infrastructure sit outside every well-to-use factor, in every library.

Gases

NGA publishes this factor as CO₂e only, with no split by gas. The CO₂e leaves biogenic CO₂ and land-use carbon out; methane from biogenic sources is counted.

From NGA's record to a comparable factor

NGA publishes the two parts; open-climate.ai added them up to this total. Here is each field as printed and what open-climate.ai made of it.

The total and its parts

Each part has its own page, with its own years and source record. Use a part on its own when you report Scope 2 and Scope 3 separately; never add a part to the total.

You are here · the totalGrid electricity, residual mix, well-to-use0.9

About this factor

NGA gives no description for this factor. Filed under Energy.

Source and licence

Value
Summed by open-climate.ai from its parts
Publisher
Department of Climate Change, Energy, the Environment and Water (DCCEEW)
Library
NGA 2026
See the source data at NGA

The values and their metadata are served in full and may be reused with credit to the publisher.

Credit it with this lineDCCEEW 2026, Australian National Greenhouse Accounts Factors, Department of Climate Change, Energy, the Environment and Water, Canberra, September. CC BY 4.0.
A plain reading of the licence, not legal advice. The licence text prevails.

Cite this factor

DCCEEW 2026, Australian National Greenhouse Accounts Factors, Department of Climate Change, Energy, the Environment and Water, Canberra, September. CC BY 4.0. Normalised by open-climate.ai, https://open-climate.ai/factors/libraries/nga_australia/ (CC BY 4.0). https://open-climate.ai/factors/ef-ngaaustralia-grid_electricity-au-kwh-well_to_use-6d1a1fca/?v=efv1-fadb7931084c2676338e46c0fcef4cbd

Something looks wrong?

Tell us which value and why. We check it against the source and answer within a week.

Page data as of .