Emission factor from ÖKOBAUDAT OBD_2024_III
District heating from light fuel oil
Germany · Well-to-use · Any year
Value for any year
0.23kgCO₂e/kWh
Fossil only · GWP100 · AR6
FossilBio CH₄Land useBio CO₂EN 15804 GWP-fossilOne value, valid until 31 December 2026
ÖKOBAUDAT sets this validity and gives no value for another period, so there is no year to pick.
Reference year 2023
- Region
- Germany DE
- Boundary
- Well-to-use
- Data quality
- MediumRated by us, not by the source
- Licence
- Open · ÖKOBAUDAT terms
Where 0.23 comes from
- Fossil emissionsScope 2 3.3 Energy upstream0.23100%
- Biogenic CO₂Outside0.000282beside
Σ 0.23: the fossil emissions are the total. ÖKOBAUDAT reports 0.000282 of biogenic CO₂ beside it, never in it.
Reporting this kilowatt-hour under the GHG Protocol
Scope 2 + 3.3 Energy upstream 0.23
This one figure covers both together; no split between them is given.
You buy the energy, so its generation is your Scope 2.
The fuel behind it and the energy lost on the way to you are Scope 3, category 3.
The factor, standardised
Every factor on open-climate.ai answers the same questions in the same words, whatever the publisher. Open any ⓘ for the definition.
Heat and cooling › District heat and steam · Germany · per kWh · Generic
Well-to-use · Fossil only · AR6
- BoundaryWell-to-useOne unit of energy as consumed, priced from the well to the point of use: the well-to-tank chain plus the burn for a fuel; generation, its well-to-tank and the transmission and distribution losses for a delivered carrier (electricity, steam or hot water, chilled water). Learn more
- Well-to-use
- Fuel supply, generation and network losses
- GWP methodWhich IPCC assessment report's warming potentials convert each gas to CO₂e, and over how many years the warming is counted (GWP100: 100 years). Learn more
- IPCC AR6, 100-year horizon
- Not on the record; set from ÖKOBAUDAT's method notes · impact method EF 3.1
- CO₂e basisWhich carbon the CO₂e counts. Fossil only leaves out biogenic methane, land-use change and biogenic CO₂; excl. biogenic CO₂ counts biogenic methane but not the other two; net total counts every pool, net of removals. The same activity on two bases is two different numbers. Learn more
- Fossil onlyFossilBio CH₄Land useBio CO₂EN 15804 GWP-fossil
- Split by carbon origin, not by gas
Medium quality · Open licence · Any year
What this number covers
The path of one kilowatt-hour of heat, from the fuel to your meter. Every step on it is counted.
Fuel supply
Extracting, processing and transporting the fuel the heat plants burn
Included, not split outHeat generation
Producing the heat and steam at the plants that feed the network
Included, not split outNetwork losses
Heat lost in the pipes between the plant and your meter, which still had to be produced
Included, not split outYour meter
1 kWh used. The factor is per kWh measured here.
= 0.23
Outside this boundary
- Building the heat plants
- Building the heat network
Capital goods and infrastructure sit outside every well-to-use factor, in every library.
Gases
- Fossil CO₂e0.23
- Biogenic CO₂e0.000282
- Land-use CO₂e0.00000965
The total counts fossil CO₂e. ÖKOBAUDAT reports biogenic and land-use CO₂e separately; they are shown beside it, not added.
From ÖKOBAUDAT's record to a comparable factor
ÖKOBAUDAT publishes this factor as one German record. Here is each field as printed and what open-climate.ai made of it.
About this factor
From ÖKOBAUDAT
What it is
This data set has been modeled according to the European Standard EN 15804+A2 for Sustainable Building. Results are depicted in modules that allow the structured expression of results over the entire life cycle.What it includes
This dataset represents the production of district heating considering the following technical parameters: the energy is produced from 100% fuel oil (light). The distribution between electricity and heat is 90/10, the efficiency of the CHP (Combined Heat and Power) is 58%. For the electricity and heat produced, allocation by exergetic content is applied (electricity exergy = 1; heat exergy = 0,33). Network losses are not calculated losses are usually around 10%. The primary energy factor is 0,70 (based on lower heating value and non-renewable energy). Background system: Electricity: Electricity is modelled according to the individual country-specific situations. The country-specific modelling is achieved on multiple levels. Firstly, individual energy carrier specific power plants and plants for renewable energy sources are modelled according to the current national electricity grid mix. Modelling the electricity consumption mix includes transmission / distribution losses and the own use by energy producers (own consumption of power plants and "other" own consumption e.g. due to pumped storage hydro power etc.), as well as imported electricity. Secondly, the national emission and efficiency standards of the power plants are modelled as well as the share of electricity plants and combined heat and power plants (CHP). Thirdly, the country-specific energy carrier supply (share of imports and / or domestic supply) including the country-specific energy carrier properties (e.g. element and energy content) are accounted for. Fourthly, the exploration, mining/production, processing and transport processes of the energy carrier supply chains are modelled according to the specific situation of each electricity producing country. The different production and processing techniques (emissions and efficiencies) in the different energy producing countries are considered, e.g. different crude oil production technologies or different flaring rates at the oil platforms. Thermal energy, process steam: The thermal energy and process steam supply is modelled according to the individual country-specific situation with regard to emission standards and considered energy carriers. The thermal energy and process steam are produced at heat plants. Efficiencies for thermal energy production are by definition 100% in relation to the corresponding energy carrier input. For process steam the efficiency ranges from 85%, 90% to 95%. The energy carriers used for the generation of thermal energy and process steam are modelled according to the specific import situation (see electricity above). Transports: All relevant and known transport processes are included. Ocean-going and inland ship transport as well as rail, truck and pipeline transport of bulk commodities are considered. Energy carriers: The energy carriers are modelled according to the specific supply situation (see electricity above). Refinery products: Diesel fuel, gasoline, technical gases, fuel oils, lubricants and residues such as bitumen are modelled with a parameterised country-specific refinery model. The refinery model represents the current national standard in refining techniques (e.g. emission level, internal energy consumption, etc.) as well as the individual country-specific product output spectrum, which can be quite different from country to country. The supply of crude oil is modelled, again, according to the country-specific situation with the respective properties of the resources.Where it applies
Thermal energy for heating of buildings.Source and licence
- Publisher
- ÖKOBAUDAT (BBSR / BMWSB)
- Library
- ÖKOBAUDAT OBD_2024_III
- Record
- 989900d3-38ad-4241-b43a-af6901326215 · process UUID
- Published
- 13 November 2026
- Valid until
- 31 December 2026
- Status
- Generic dataset
The values and their metadata are served in full and may be reused with credit to the publisher.
Cite this factor
Source: ÖKOBAUDAT (OBD_2024_III), BBSR / BMWSB. Individual EPDs © their respective programme operators / declaration owners. Normalised by open-climate.ai, https://open-climate.ai/factors/libraries/okobaudat/ (CC BY 4.0). https://open-climate.ai/factors/ef-okobaudat-district_heating_from-de-kwh-b6-42e97309/?v=efv1-a18e03ff63fec3863921d7065de9e40e
Something looks wrong?
Tell us which value and why. We check it against the source and answer within a week.
Page data as of .