Emission factor from ÖKOBAUDAT OBD_2024_III
Electricity from photovoltaics (1 kWh)
Germany · Well-to-use · Any year
Value for any year
0.0342kgCO₂e/kWh
Fossil only · GWP100 · AR6
FossilBio CH₄Land useBio CO₂EN 15804 GWP-fossilOne value, valid until 31 December 2026
ÖKOBAUDAT sets this validity and gives no value for another period, so there is no year to pick.
Reference year 2023
- Region
- Germany DE
- Boundary
- Well-to-use
- Data quality
- MediumRated by us, not by the source
- Licence
- Open · ÖKOBAUDAT terms
Where 0.0342 comes from
ÖKOBAUDAT prints this factor as a single figure, with no parts to add up.
Reporting this kilowatt-hour under the GHG Protocol
Scope 2 + 3.3 Energy upstream 0.0342
This one figure covers both together; no split between them is given.
You buy the energy, so its generation is your Scope 2.
The fuel behind it and the energy lost on the way to you are Scope 3, category 3.
The factor, standardised
Every factor on open-climate.ai answers the same questions in the same words, whatever the publisher. Open any ⓘ for the definition.
Electricity › Electricity by generation technology · Germany · per kWh · Generic
Well-to-use · Fossil only · AR6
- BoundaryWell-to-useOne unit of energy as consumed, priced from the well to the point of use: the well-to-tank chain plus the burn for a fuel; generation, its well-to-tank and the transmission and distribution losses for a delivered carrier (electricity, steam or hot water, chilled water). Learn more
- Well-to-use
- Fuel supply, generation and network losses
- GWP methodWhich IPCC assessment report's warming potentials convert each gas to CO₂e, and over how many years the warming is counted (GWP100: 100 years). Learn more
- IPCC AR6, 100-year horizon
- Not on the record; set from ÖKOBAUDAT's method notes · impact method EF 3.1
- CO₂e basisWhich carbon the CO₂e counts. Fossil only leaves out biogenic methane, land-use change and biogenic CO₂; excl. biogenic CO₂ counts biogenic methane but not the other two; net total counts every pool, net of removals. The same activity on two bases is two different numbers. Learn more
- Fossil onlyFossilBio CH₄Land useBio CO₂EN 15804 GWP-fossil
- Split by carbon origin, not by gas
- Life cycle
- Upstream: coveredProduction: coveredDownstream: not applicableEnd of life: not applicable
Medium quality · Open licence · Any year
What this number covers
The path of one kilowatt-hour, from the fuel to your meter. Every step on it is counted.
Fuel supply
Extracting, processing and transporting the fuel the plants burn
Included, not split outGeneration
Producing the electricity at the power plants that make up the mix
Included, not split outNetwork losses
Electricity lost between the plant and your meter, which still had to be generated
Included, not split outYour meter
1 kWh used. The factor is per kWh measured here.
= 0.0342
Outside this boundary
- Building the power plants
- Building the grid
Capital goods and infrastructure sit outside every well-to-use factor, in every library.
Gases
- Fossil CO₂e0.0342
- Biogenic CO₂e−0.000234
- Land-use CO₂e0.0000282
The total counts fossil CO₂e. ÖKOBAUDAT reports biogenic and land-use CO₂e separately; they are shown beside it, not added.
From ÖKOBAUDAT's record to a comparable factor
ÖKOBAUDAT publishes this factor as one German record. Here is each field as printed and what open-climate.ai made of it.
About this factor
From ÖKOBAUDAT
What it is
This data set has been modeled according to the European Standard EN 15804+A2 for Sustainable Building. Results are depicted in modules that allow the structured expression of results over the entire life cycle.What it includes
The data set includes the production of the photovoltaic systems based on the global average market mix of installed photovoltaic technologies: monocrystalline cells 42%, polycrystalline cells 47%, cadmium telluride cells (CdTe) 7% and copper-indium-gallium-diselenide cells 4% . The manufacturing and operation of the system are taken into account. The service life of the panels is modeled at 20 years. The following average efficiencies per technology are used: monocrystalline cells 18%, polycrystalline cells 16%, cadmium telluride (CdTe) 17%, copper-indium-gallium-diselenide 15%. The system efficiency is taken into account at 75% for pitched roof installation and 80% for floor installation. The proportion of pitched roof installation is 90%.Where it applies
Electrical energy is required for the operation of various technical systems and installations in the building context.Source and licence
- Publisher
- ÖKOBAUDAT (BBSR / BMWSB)
- Library
- ÖKOBAUDAT OBD_2024_III
- Record
- 7f5a034f-5541-4ac4-90ff-c1c41d7c93db · process UUID
- Published
- 13 November 2026
- Valid until
- 31 December 2026
- Status
- Generic dataset
The values and their metadata are served in full and may be reused with credit to the publisher.
Cite this factor
Source: ÖKOBAUDAT (OBD_2024_III), BBSR / BMWSB. Individual EPDs © their respective programme operators / declaration owners. Normalised by open-climate.ai, https://open-climate.ai/factors/libraries/okobaudat/ (CC BY 4.0). https://open-climate.ai/factors/ef-okobaudat-electricity_from-de-kwh-b6-beb9b02f/?v=efv1-389c417365351ff3cbc0bed38781126e
Something looks wrong?
Tell us which value and why. We check it against the source and answer within a week.
Page data as of .