Emission factor from ÖKOBAUDAT OBD_2024_III EPD, industry average

Metal Ceiling Membranes (0.5 mm, without acoustic infill)

Europe · EPD total · Reference year 2022

Each square metre of this product counts as 17.4 kg CO₂e over the modules its EPD declares: 17.4 to make it (A1–A3) and 0.0231 at end of life.

Value per square metre, over the modules the EPD declares

17.4kgCO₂e/m²

EN 15804 modules A1 to A3 · Fossil only · GWP100 · AR5

FossilBio CH₄Land useBio CO₂EN 15804 GWP-fossil

Derived by open-climate.ai: the sum of ÖKOBAUDAT's published parts

The one scenario this EPD declaresReference year 2022

Region
Europe
Boundary
EPD total
Data quality
MediumRated by us, not by the source
Licence
Open · ÖKOBAUDAT terms
Declared by
Knauf Ceiling Solutions GmbH & Co. KG

Where 17.4 comes from

Derived by open-climate.ai

Σ 17.4: the two declared modules add up to the total. D stays beside it.

Reporting this square metre under the GHG Protocol

This period

3.1 Goods we buy 17.4

You buy the product for a building that is not yours. The product and its installation go to category 1, the delivery to category 4. The use stage belongs to the building owner; demolition waste you handle is category 5.

Later, when it happens

At end of life, in the year of demolition

  • End of life 3.5 Waste 0.0231

Outside the scopes, reported separately

  • D −8.26

A4, A5, B1 to B7 and C1 to C4 are not declared: nothing to report.

CiteAPI

The factor, standardised

Every factor on open-climate.ai answers the same questions in the same words, whatever the publisher. Open any ⓘ for the definition.

Materials › Metals · Europe · per m² · Average

EPD total · Fossil only · AR5

Boundary
EPD total
Raw materials, inbound transport, fuel supply, fuel combustion, manufacturing, packaging, purchased energy and end of life
GWP method
IPCC AR5, 100-year horizon
Not on the record; set from ÖKOBAUDAT's method notes · impact method EF 3.0
CO₂e basis
Fossil onlyFossilBio CH₄Land useBio CO₂EN 15804 GWP-fossil
Split by carbon origin, not by gas
Life cycle
Upstream: coveredProduction: coveredDownstream: not coveredEnd of life: partly covered

Medium quality · Open licence · Any year

Module by module, up to the total

Seventeen EN 15804 modules, always in the same order. Each declared one moves the running total. D sits below zero after the total, because it is reported beside it.

kgCO₂e per square metre. Each bar starts where the one before ended. Pick a module to read it.
Product
Con­struc­tion
A4 to A5not de­clared
Use
B1 to B7not de­clared
End of life
C1not de­clared
C3not de­clared
Beyond the boundary

beside the total, not in it

What this number covers

Follow one square metre of this product through EN 15804's stages. The total counts what the EPD declares; what it leaves out stays visible.

  1. A1-A3Product

    Materials and making the product

    Included17.4
  2. A4-A5Construction

    Delivery and installation

    Not declared
  3. B1-B7Use

    The product in service: maintenance, repair, replacement and the energy and water it uses

    Not declared
  4. C1-C4End of life

    From demolition to disposal; C1, C3 not declared

    C2, C40.0231
  5. DBeyond the boundary

    Recovery after end of life

    Not in the total−8.26

Outside this boundary

  • Installation
  • Maintenance
  • Outbound transport
  • Retail
  • Use phase
  • Recycling credit

Maintenance is out because B2 is not declared. The recycling credit is module D, shown beside the total.

Gases

  • Fossil CO₂e17.4
  • Biogenic CO₂e−0.332
  • Land-use CO₂e0.0086

The total counts fossil CO₂e. ÖKOBAUDAT reports biogenic and land-use CO₂e separately; they are shown beside it, not added.

From ÖKOBAUDAT's record to a comparable factor

ÖKOBAUDAT publishes this EPD as one declared value. Each field as printed, and what open-climate.ai made of it.

The total and its modules

Use a module on its own when you report it in a different year or scope; never add one to the total.

You are here · the EPD total17.4
D beside−8.26
The two modules add up to the total; D stays beside it. Each opens its own page.

About this factor

From ÖKOBAUDAT

What it is

Knauf Ceiling Solutions metal ceiling systems are made from punched and formed galvanised steel, as comprehensive construction kits or individual components and industrially manufactured. The construction kit comprises the visible membrane and the substructure. The components (tiles) are offered with various edge details and delivered unperforated or with a range of perforation patterns, fulfilling the functional requirements. The substructure is either exposed or concealed.

What it includes

The system components for metal ceilings are manufactured in a continuous manufacturing process. The sheet steel comes mainly in coils, gets optionally perforated, afterwards cut to size, punched, formed and powder-coated after the cleaning process. Punching and perforation waste is gathered, collected by local disposal companies, and redirected to the recycling centres. All production steps are carried out in accordance with the requirements and test guidelines outlined in EN 13964. The manufacturing plants are certified according to ISO 9001 and ISO 14001. Technical data: Metal membranes are regulated by EN 13964 and have corresponding labelling and declaration of performance. The following data provide an overview of results: Declared unit: This EPD refers to a declared unit of 1 m² of average steel ceiling membrane with a thickness of 0.5 mm (Standard white RAL 9010) and a surface weight of 4.25 kg/m² without acoustic infill.
Show ÖKOBAUDAT's original (German)
Die Systemkomponenten für Metalldecken werden in einem kontinuierlichen Fertigungsprozess hergestellt. Das Stahlblech kommt hauptsächlich in Coils, wird optional perforiert, anschließend zugeschnitten, gestanzt, geformt und nach dem Reinigungsprozess pulverbeschichtet. Stanz- und Perforationsabfälle werden gesammelt, von lokalen Entsorgungsunternehmen abgeholt und an die Recyclingzentren weitergeleitet. Alle Produktionsschritte werden in Übereinstimmung mit den in der EN 13964 festgelegten Anforderungen und Testrichtlinien durchgeführt. Die Produktionsstätten sind nach ISO 9001 und ISO 14001 zertifiziert. Technische Daten: Metallmembranen sind durch die EN 13964 geregelt und verfügen über eine entsprechende Kennzeichnung und Leistungserklärung. Die folgenden Daten geben einen Überblick über die Ergebnisse: Deklarierte Einheit: Diese EPD bezieht sich auf eine deklarierte Einheit von 1 m² durchschnittlicher Stahldeckenmembran mit einer Dicke von 0,5 mm (Standard weiß RAL 9010) und einem Flächengewicht von 4,25 kg/m² ohne akustische Füllung.

Where it applies

The described metal solutions are typically used internally as design elements, to cover the ceiling void, as well as acoustic solutions for sound absorption and sound attenuation, for fire resistance and against fire spreading, for cleanrooms and high hygiene requirements.

Source and licence

Value
Summed by open-climate.ai from its parts
Publisher
ÖKOBAUDAT (BBSR / BMWSB)
Published
13 November 2026
Valid until
31 December 2027
See the source data at ÖKOBAUDAT

The values and their metadata are served in full and may be reused with credit to the publisher.

Credit it with this lineSource: ÖKOBAUDAT (OBD_2024_III), BBSR / BMWSB. Individual EPDs © their respective programme operators / declaration owners.
The publisher's text on this page is translated by open-climate.ai.A plain reading of the licence, not legal advice. The licence text prevails.

Cite this factor

Source: ÖKOBAUDAT (OBD_2024_III), BBSR / BMWSB. Individual EPDs © their respective programme operators / declaration owners. Normalised by open-climate.ai, https://open-climate.ai/factors/libraries/okobaudat/ (CC BY 4.0). https://open-climate.ai/factors/ef-okobaudat-metal_ceiling_membranes-europe-m2-epd_total-534f8676/?v=efv1-f79f4cb48b39035069fa648e93f5940b

Something looks wrong?

Tell us which value and why. We check it against the source and answer within a week.

Page data as of .