Value per tonne of goods carried one kilometre
0.0168kgCO₂e/t.km
Fossil only · GWP100 · AR6
FossilBio CH₄Land useBio CO₂EN 15804 GWP-fossilOne value, valid until 31 December 2026
ÖKOBAUDAT sets this validity and gives no value for another period, so there is no year to pick.
Reference year 2023
- LoadHow full the vehicle runs. ÖKOBAUDAT does not say which load this factor assumes.
- Not stated
- Vehicle sizeThe vehicle's class, by weight or capacity. ÖKOBAUDAT does not say which size this factor assumes.
- Not stated
- Distance bandFlights are priced by distance band, because take-off and climb burn a large share of a short flight's fuel. Road, rail and sea factors apply to a trip of any length.
- Any distance, not banded
- Cabin classA business seat takes more of the cabin than an economy one, so it carries more of the flight's emissions. First class on a long-haul flight counts four times economy.
- Not applicable
- Region
- Germany DE
- Boundary
- Well-to-use
- Data quality
- MediumRated by us, not by the source
- Licence
- Open · ÖKOBAUDAT terms
Where 0.0168 comes from
- Fossil emissions3.4 Freight we pay0.0168100%
- Biogenic CO₂Outside0.000182beside
Σ 0.0168: the fossil emissions are the total. ÖKOBAUDAT reports 0.000182 of biogenic CO₂ beside it, never in it.
Reporting this tonne-kilometre under the GHG Protocol
3.4 Freight we pay 0.0168
You pay a carrier to bring goods in, or to move them between your own sites. All of it goes in upstream transport.
The factor, standardised
Every factor on open-climate.ai answers the same questions in the same words, whatever the publisher. Open any ⓘ for the definition.
Transport › Rail freight · Germany · per t.km · Generic
Well-to-use · Fossil only · AR6
- BoundaryWell-to-useOne unit of energy as consumed, priced from the well to the point of use: the well-to-tank chain plus the burn for a fuel; generation, its well-to-tank and the transmission and distribution losses for a delivered carrier (electricity, steam or hot water, chilled water). Learn more
- Well-to-use
- Fuel supply, fuel combustion and purchased energy
- GWP methodWhich IPCC assessment report's warming potentials convert each gas to CO₂e, and over how many years the warming is counted (GWP100: 100 years). Learn more
- IPCC AR6, 100-year horizon
- Not on the record; set from ÖKOBAUDAT's method notes · impact method EF 3.1
- CO₂e basisWhich carbon the CO₂e counts. Fossil only leaves out biogenic methane, land-use change and biogenic CO₂; excl. biogenic CO₂ counts biogenic methane but not the other two; net total counts every pool, net of removals. The same activity on two bases is two different numbers. Learn more
- Fossil onlyFossilBio CH₄Land useBio CO₂EN 15804 GWP-fossil
- Split by carbon origin, not by gas
Medium quality · Open licence · Any year
Per tonne, per vehicle or per passenger
One trip, three ways to count it. Pick the unit you have a number for.
One tonne of goods carried one kilometre. Use it when you know what the shipment weighs.
0.016812 t over 300 km is 3,600 t.km, so 60.4 kg CO₂e
One person carried one kilometre, on a bus, a train or a flight. It never applies to goods.
Not for goodsWhat this number covers
The path of one tonne-kilometre, from the oil well to the delivered load.
Fuel production
Extracting, refining and delivering the fuel
IncludedTrain operation
The energy the train uses, diesel or electric, spread over the average load
IncludedYour shipment
1 tonne moved 1 km. The factor is per tonne-kilometre.
= 0.0168
Outside this boundary
- Building the train
- Tracks and stations
Vehicles and infrastructure sit outside every well-to-use factor. Some libraries price building the vehicle as a factor of its own.
Gases in train operation
- Fossil CO₂e0.0168
- Biogenic CO₂e0.000182
- Land-use CO₂e0.00000321
The total counts fossil CO₂e. ÖKOBAUDAT reports biogenic and land-use CO₂e separately; they are shown beside it, not added.
From ÖKOBAUDAT's record to a comparable factor
ÖKOBAUDAT publishes this factor as one German record. Here is each field as printed and what open-climate.ai made of it.
About this factor
From ÖKOBAUDAT
What it is
This data set has been modeled according to the European Standard EN 15804+A2 for Sustainable Building. Results are depicted in modules that allow the structured expression of results over the entire life cycle.What it includes
The dataset refers to the transport of 1000 kg cargo on a a distance of 1 km by railway with electric powertrain, 1000 t permissible total weight and 726 t payload with a utilisation ratio of 40%. The electricity consumption is 0,116 MJ/tkm.Where it applies
This product can be used in construction.Source and licence
- Publisher
- ÖKOBAUDAT (BBSR / BMWSB)
- Library
- ÖKOBAUDAT OBD_2024_III
- Record
- b04a12ef-0842-4ee9-b411-02d8073f0f96 · process UUID
- Published
- 13 November 2026
- Valid until
- 31 December 2026
- Status
- Generic dataset
The values and their metadata are served in full and may be reused with credit to the publisher.
Cite this factor
Source: ÖKOBAUDAT (OBD_2024_III), BBSR / BMWSB. Individual EPDs © their respective programme operators / declaration owners. Normalised by open-climate.ai, https://open-climate.ai/factors/libraries/okobaudat/ (CC BY 4.0). https://open-climate.ai/factors/ef-okobaudat-rail_transport-de-tkm-a4-64720bda/?v=efv1-c41c7bb9d2487c11e67f82b1174ac6bf
Something looks wrong?
Tell us which value and why. We check it against the source and answer within a week.
Page data as of .