Emission factor from ÖKOBAUDAT OBD_2024_III EPD, industry average
Zinc coated and painted steel structures (SIA LSEZ RT metāls)
World · EPD total · Reference year 2021
Each kilogram of this product counts as 1.86 kg CO₂e over the modules its EPD declares: 1.81 to make it (A1–A3), 0.0322 to deliver and place it (A4) and 0.0111 at end of life.
Value per kilogram, over the modules the EPD declares
1.86kgCO₂e/kg
EN 15804 modules A1 to A4 · Fossil only · GWP100 · AR5
FossilBio CH₄Land useBio CO₂EN 15804 GWP-fossilDerived by open-climate.ai: the sum of ÖKOBAUDAT's published parts
Standard scenarioReference year 2021
- Region
- World GLOBAL
- Boundary
- EPD total
- Data quality
- MediumRated by us, not by the source
- Licence
- Open · ÖKOBAUDAT terms
- Declared by
- SIA LSEZ RT metāls
Where 1.86 comes from
- A1-A3 Product stageDerived by open-climate.ai3.1 Goods we buy1.8197.7%
- 3.4 Freight we pay0.03221.7%
- End of lifeDerived by open-climate.ai3.5 Waste0.01110.6%
- Outside−0.0925beside
Σ 1.86: the three declared modules add up to the total. D stays beside it.
Reporting this kilogram under the GHG Protocol
This period
3.1 Goods we buy 1.81 3.4 Freight we pay 0.0322
You buy the product for a building that is not yours. The product and its installation go to category 1, the delivery to category 4. The use stage belongs to the building owner; demolition waste you handle is category 5.
Later, when it happens
At end of life, in the year of demolition
- End of life 3.5 Waste 0.0111
Outside the scopes, reported separately
- D −0.0925
A5, B1 to B7 and C1 to C4 are not declared: nothing to report.
The factor, standardised
Every factor on open-climate.ai answers the same questions in the same words, whatever the publisher. Open any ⓘ for the definition.
Materials › Metals · World · per kg · Average
EPD total · Fossil only · AR5
- BoundaryEPD totalThe sum of every EN 15804 module an EPD declares, when that set is not the complete A-C grid (MOD-0034). Learn more
- EPD total
- Raw materials, inbound transport, fuel supply, fuel combustion, manufacturing, packaging, purchased energy, outbound transport and end of life
- GWP methodWhich IPCC assessment report's warming potentials convert each gas to CO₂e, and over how many years the warming is counted (GWP100: 100 years). Learn more
- IPCC AR5, 100-year horizon
- Not on the record; set from ÖKOBAUDAT's method notes · impact method EF 3.0
- CO₂e basisWhich carbon the CO₂e counts. Fossil only leaves out biogenic methane, land-use change and biogenic CO₂; excl. biogenic CO₂ counts biogenic methane but not the other two; net total counts every pool, net of removals. The same activity on two bases is two different numbers. Learn more
- Fossil onlyFossilBio CH₄Land useBio CO₂EN 15804 GWP-fossil
- Split by carbon origin, not by gas
- Life cycle
- Upstream: coveredProduction: coveredDownstream: partly coveredEnd of life: partly covered
Medium quality · Open licence · Any year
Module by module, up to the total
Seventeen EN 15804 modules, always in the same order. Each declared one moves the running total. D sits below zero after the total, because it is reported beside it.
beside the total, not in it
| Module | Name | Per kilogram | Running total | Status |
|---|---|---|---|---|
| A1 | Raw material supply | 0.757 | 0.757 | Declared |
| A2 | Transport to the plant | 0.236 | 0.993 | Declared |
| A3 | Manufacturing | 0.821 | 1.814 | Declared |
| A4 | Transport to site | 0.0322 | 1.8462 | Declared |
| A5 | Installation | not declared | 1.8462 | Not declared |
| B1 | Use | not declared | 1.8462 | Not declared |
| B2 | Maintenance | not declared | 1.8462 | Not declared |
| B3 | Repair | not declared | 1.8462 | Not declared |
| B4 | Replacement | not declared | 1.8462 | Not declared |
| B5 | Refurbishment | not declared | 1.8462 | Not declared |
| B6 | Energy in use | not declared | 1.8462 | Not declared |
| B7 | Water in use | not declared | 1.8462 | Not declared |
| C1 | Demolition | 0.00361 | 1.84981 | Declared |
| C2 | Waste transport | 0.00709 | 1.8569 | Declared |
| C3 | Waste processing | not declared | 1.8569 | Not declared |
| C4 | Disposal | 0.000448 | 1.85735 | Declared |
| Total | EPD total, declared modules | 1.85735 | Sum of the declared modules | |
| D | Beyond the system boundary | −0.0925 | not added | Beside the total, not in it |
What this number covers
Follow one kilogram of this product through EN 15804's stages. The total counts what the EPD declares; what it leaves out stays visible.
A1-A3Product
Materials and making the product
Included1.81A4-A5Construction
Transport to site only; A5 not declared
A4 only0.0322B1-B7Use
The product in service: maintenance, repair, replacement and the energy and water it uses
Not declaredC1-C4End of life
From demolition to disposal; C3 not declared
C1, C2, C40.0111DBeyond the boundary
Recovery after end of life
Not in the total−0.0925
Outside this boundary
- Installation
- Maintenance
- Retail
- Use phase
- Recycling credit
Maintenance is out because B2 is not declared. The recycling credit is module D, shown beside the total.
Gases
- Fossil CO₂e1.86
- Biogenic CO₂e−0.0673
- Land-use CO₂e0.00244
The total counts fossil CO₂e. ÖKOBAUDAT reports biogenic and land-use CO₂e separately; they are shown beside it, not added.
From ÖKOBAUDAT's record to a comparable factor
ÖKOBAUDAT publishes this EPD with one value per module. Each field as printed, and what open-climate.ai made of it.
The total and its modules
Use a module on its own when you report it in a different year or scope; never add one to the total.
About this factor
From ÖKOBAUDAT
What it is
The average EPD (type: Cradle to gate with options, modules C1-C4 and module D (A1- A4, C, D)) is based on LCA of the custom made zinc coated steel structures, manufactured in Liepāja, Latvia. This EPD contains results of two sub-types: zinc coated steel structures and zinc coated and additionally painted steel structures. The calculation is based on 1 kg of zinc coated steel structure with a share of 93,27% steel materials and zinc coated and painted steel structure with a share of 90,94% steel materials. Kiwa-Ecobility Experts shall not be liable with respect to manufacturer information, life cycle assessment data and evidence.What it includes
Zinc coated or hot-dip galvanized steel structures are used in various areas of construction, for example construction of bridges, telecommunications towers, engineering, industrial and public buildings, as well as in the agriculture and energy industry. Hot-dip galvanizing is especially valued in objects that are located in an aggressive, corrosion-enhancing environment. The steel structures are manufactured according to EN 1090-2, up to EXC 4, and are CE marked. UN CPC code: 421 Structural metal products and parts thereof. The steel structures of industrial and civil objects are made according to the developed drawings. The manufacturing contains the following processes: • Extraction and delivery of raw materials; • Cutting; • Assembling; • Welding; • Sand blasting; • Coating (hot-dip galvanization (external treatment) and additional priming and painting); • Storage; • Transportation (delivery of finished products). Since hot-dip galvanization is outsourced process, A1 for zinc layer does not include transportation. Transportation is included in A3 (incl. both ways).Where it applies
The area of application of zinc coated steel structure includes mostly outdoor residential and commercial construction elements, where high corrosion protection is needed (galvanized balconies, car ports, stairs, railings, balustrades, canopies, etc.), street furniture (fencing, walkways, gates), as well as various leisure, sport and playground elements (swings, football goals, railings, etc).Source and licence
- Value
- Summed by open-climate.ai from its parts
- Publisher
- ÖKOBAUDAT (BBSR / BMWSB)
- Library
- ÖKOBAUDAT OBD_2024_III
- Published
- 13 November 2026
- Valid until
- 31 December 2027
The values and their metadata are served in full and may be reused with credit to the publisher.
Cite this factor
Source: ÖKOBAUDAT (OBD_2024_III), BBSR / BMWSB. Individual EPDs © their respective programme operators / declaration owners. Normalised by open-climate.ai, https://open-climate.ai/factors/libraries/okobaudat/ (CC BY 4.0). https://open-climate.ai/factors/ef-okobaudat-zinc_coated_and_painted-global-kg-epd_total-9998f7ea/?v=efv1-6296295cecc9e8bb90821f8a0f6a96b2
Something looks wrong?
Tell us which value and why. We check it against the source and answer within a week.