Emission factor from ProBas v02.44.152

Electricity, heat pump, mono, air, DE, 2010, mix

Germany · Useful heat, full life cycle · Any year

Each kilowatt-hour of heat or steam bought counts as 0.188 kg CO₂e. ProBas gives one figure, for use in any year.

Value for any year

0.188kgCO₂e/kWh

Biogenic CO₂ and land use excluded · GWP100 · AR6

FossilBio CH₄Land useBio CO₂GHG Protocol and IPCC inventories

One value, for any year

ProBas sets no date window, so there is no year to pick.

Reference year 2010

Region
Germany DE
Boundary
Useful heat, full life cycle
Data quality
MediumRated by us, not by the source
Licence
Open · ProBas terms

Where 0.188 comes from

Published as one number

ProBas prints this factor as a single figure, with no parts to add up.

Reporting this kilowatt-hour under the GHG Protocol

Scope 1 + Scope 2 + Scope 3, categories 2 and 3 0.188

This one figure covers all four together; no split between them is given.

Emissions from equipment you run are direct emissions, so they are your Scope 1.

Building the plant is a capital good: Scope 3, category 2.

Producing and delivering the fuel it burns happened upstream: Scope 3, category 3.

CiteAPI

The factor, standardised

Every factor on open-climate.ai answers the same questions in the same words, whatever the publisher. Open any ⓘ for the definition.

Heat and cooling › Heat generation · Germany · per kWh · Average

Useful heat, full life cycle · Excl. biogenic CO₂ · AR6

Boundary
Useful heat, full life cycle
Fuel supply, generation and capital goods
GWP method
IPCC AR6, 100-year horizon
Re-weighted by open-climate.ai from ProBas's AR5 figure of 0.188 kgCO₂e/kWh
CO₂e basis
Excl. biogenic CO₂FossilBio CH₄Land useBio CO₂GHG Protocol and IPCC inventories
Split by gas

Medium quality · Open licence · Any year

What this number covers

The path of one kilowatt-hour of heat, from the fuel to your meter. Every step on it is counted.

  1. Fuel supply

    Extracting, processing and transporting the fuel the heat plants burn

    Included, not split out
  2. Heat generation

    Producing the heat and steam at the plants that feed the network

    Included, not split out
  3. Also counted

    • Building the heat plants
    Included, not split out
  4. Your meter

    1 kWh used. The factor is per kWh measured here.

    = 0.188

Gases

Basis: Excl. biogenic CO₂FossilBio CH₄Land useBio CO₂GHG Protocol and IPCC inventories

  • Fossil CO₂0.17894.8%
  • Methane (CH₄)0.007143.8%
  • Nitrous oxide (N₂O)0.002671.4%

Σ 0.178 + 0.00714 + 0.00267 = 0.187723, which ProBas rounds to 0.188.

Also printed, as zero: sulphur hexafluoride (SF₆).

Each gas is converted to CO₂e with AR6 100-year warming potentials; biogenic CO₂ and land-use carbon are left out, while methane from biogenic sources is counted.

From ProBas's record to a comparable factor

ProBas publishes this factor as one record. Here is each field as printed and what open-climate.ai made of it.

About this factor

From ProBas

Translated from German
monoenergetic electric heat pump for low-temperature heating system, heat source air, with electric reheating for cold days. The heat pump electricity here comes 100 % from the power plant mix (mix case); data on the annual efficiency increased by 7.5% compared with 2000. Load factor: 1600h/a Fuel/input: Electricity Firm capacity: 100% Year: 2010 Lifetime: 20a Capacity: 0.005MW Efficiency: 350% Product: Heat, space heating
Show ProBas's original (German)
monoenergetische elektrische Wärmepumpe für Niedertemperatur-Heizsystem, Wärmequelle Luft, mit elektrischer Nachheizung für kalte Tage. Der Wärmepumpen-Strom kommt hier zu 100 % aus Kraftwerks-Mix (Mix-Fall); Daten zum Jahresnutzungsgrad um 7,5% gegenüber 2000 erhöht. Auslastung: 1600h/a Brenn-/Einsatzstoff: Elektrizität gesicherte Leistung: 100% Jahr: 2010 Lebensdauer: 20a Leistung: 0,005MW Nutzungsgrad: 350% Produkt: Wärme - Heizen

Source and licence

Publisher
Umweltbundesamt (German Environment Agency), ProBas
Record
7f2ed3e6-1c08-4133-88b7-1f0d1a16a0f5
Published
16 September 2020
Open the record at ProBas

The values and their metadata are served in full and may be reused with credit to the publisher.

Es gelten die Probas Nutzungsbedingungen, die hier eingesehen werden können: https://probas.umweltbundesamt.de/daten/static/Nutzungsbedingungen_ProBas.pdf
Credit it with this lineProBas, Umweltbundesamt
A plain reading of the licence, not legal advice. The licence text prevails.

Cite this factor

ProBas, Umweltbundesamt. Normalised by open-climate.ai, https://open-climate.ai/factors/libraries/probas/ (CC BY 4.0). https://open-climate.ai/factors/ef-probas-elwarmepumpemonoluftde20-de-kwh-useful_heat_lifecycle-29b10e24/?v=efv1-4bef5d16a6aad1539750d5ace89ad635

Something looks wrong?

Tell us which value and why. We check it against the source and answer within a week.