Heat generation emission factors
Heat produced on site or by a dedicated installation rather than bought from a network: solar thermal, heat pumps, shallow and deep geothermal, ambient heat. From 12 libraries, filed in one model so one publisher's factor compares with another's.
Median 0.396 kgCO₂e/kWh over 158 factors, from 0.00892 to 1.12.
Group: Per kWh, Useful heat, full life cycle
How much CO₂e, at a glance
The median of the largest groups that compare. A group shares one unit, one boundary and one accounting method, so a card never mixes them.
Per kWh
Useful heat, full life cycle
0.396 kg CO₂e
Median of 158 factors. Half of them sit between 0.149 and 0.577. 282 more are licence-restricted and left out.
Per kWh
Energy, full life cycle
0.448 kg CO₂e
Median of 8 factors. Half of them sit between 0.403 and 0.48. 269 more are licence-restricted and left out.
Per kwh_primary
Well-to-use
0.11 kg CO₂e
Median of 8 factors. Half of them sit between 0.0265 and 0.172.
Per kWh
Well-to-use
0.0344 kg CO₂e
Median of 6 factors. Half of them sit between 0.0268 and 0.118.
Source: open-climate.ai catalogue, version 2360, coverage summed over libraries.
How far apart the factors are
One row per comparable group, each chart on its own scale. Physical units and spend never share a chart.
- Lowest to highest
- Middle half of the factors
- Median
Per kWh
| Group | Factors | kg CO₂e per kWh | Lowest | Middle half | Median | Highest |
|---|---|---|---|---|---|---|
| Useful heat, full life cycle | 158 | 0.00892 | 0.149 to 0.577 | 0.396 | 1.12 | |
| Energy, full life cycle | 8 | 0.059 | 0.403 to 0.48 | 0.448 | 0.544 | |
| Well-to-use | 6 | 0.0215 | 0.0268 to 0.118 | 0.0344 | 0.209 |
Per kwh_primary
| Group | Factors | kg CO₂e per kwh_primary | Lowest | Middle half | Median | Highest |
|---|---|---|---|---|---|---|
| Well-to-use | 8 | 0.0224 | 0.0265 to 0.172 | 0.11 | 0.176 |
Source: open-climate.ai catalogue, version 2360, coverage summed over libraries.
One thing, several units
Each unit is its own comparison. A factor per litre never sits on one axis with a factor per kilogram, and a factor per unit of spend never sits with a physical one: convert your quantity into the factor's unit, not the factor.
per kWh
727 factors · 552 licence-restricted
Boundaries: Useful heat, full life cycle (fuel cycle and heating system), Energy, full life cycle (fuel cycle and asset), Well-to-use (upstream, burn or generation, network losses), Combustion (direct, at point of use), Generation, and Generation and upstream (before network losses)
per kwh_primary
8 factors
Boundaries: Well-to-use (upstream, burn or generation, network losses)
What does each total include?
6 boundaries are in use in this category, and a total on one does not compare with a total on another. Read down a column to see what it counts.
| Part of the total | Useful heat, full life cycle440 factors | Energy, full life cycle277 factors | Well-to-use14 factors | Combustion2 factors | Generation1 factor | Generation and upstream1 factor |
|---|---|---|---|---|---|---|
| Transmission and distribution losses | Not stated | Not stated | Not stated | Not included | Not included | Not stated |
| Upstream fuel (well-to-tank) | Included | Included | Included | Not included | Not included | Not stated |
| Fuel combustion | Included | Included | Included | Included | Included | Not stated |
| Purchased electricity and heat | Not stated | Not stated | Included | Not included | Included | Not stated |
| Capital goods | Included | Included | Included | Not included | Not included | Not stated |
| Infrastructure | Not stated | Not stated | Not included | Not included | Not stated | Not stated |
| Overheads and services | Not stated | Included | Not stated | Not stated | Not stated | Not stated |
Varies: some factors on this boundary include it and others do not. Not stated: the publisher does not say. How system boundaries work
Values not shown
552 of the 735 factors in this category are not shown. Licence-restricted: ecoinvent (518), KBOB (33), and AusLCI (1). They are counted on this page. Their values are never drawn, ranked or used in a median. How licences work here
Which factor should you use?
What you report decides the boundary. The unit follows your invoice.
Fuel you burn yourself
Vehicles, boilers and generators you operate.
Use the combustion factor, per litre or per kWh as invoiced.
The supply chain of that fuel
Extraction, refining and delivery of what you burned.
Use the upstream fuel factor of the same library and year.
One number for both
A footprint that does not split scopes.
Use the well-to-wheel total, never added to either part.
Only a spend figure
You know what you paid, not the quantity.
Use a spend factor in the currency and year of the invoice.
Libraries that publish these factors
12 libraries, by number of factors.
| Library | Factors | Boundary | Values | Latest |
|---|---|---|---|---|
| ecoinvent | 518 | Energy, full life cycle, Useful heat, full life cycle | Licence-restricted | 2025 |
| ProBas | 152 | Useful heat, full life cycle | Shown | 2020 |
| KBOB | 33 | Useful heat, full life cycle | Licence-restricted | 2022 |
| UBA (DE) | 12 | Well-to-use | Shown | 2024 |
| GEMIS | 6 | Useful heat, full life cycle | Shown | 2020 |
| ICM | 6 | Energy, full life cycle | Shown | 2015 |
| CoM | 2 | Combustion | Shown | 2024 |
| Syke | 2 | Energy, full life cycle | Shown | 2020 |
4 more libraries
Source: open-climate.ai catalogue, version 2360, coverage summed over libraries.
Other subcategories
- District heat and steam2,214 factors
- Cooling77 factors
Have a procurement file?
Send it and we'll match every line.
Highlighted factor pages
Sorted by library. Each factor is also on its library's page.
| Activity | Library | Region | Boundary | Value | Year |
|---|---|---|---|---|---|
| Geothermal | CoM | World | Combustion | 0 kgCO₂e/kWh | 2024 |
| Energy reduction, ventilation system, 6 x 120 m3/h, steel ducts, with GHE | ICM | Australia | Energy, full life cycle | 0.468 kgCO₂e/kWh | 2015 |
| Italy electricity and heat emission factor - heat generation | ISPRA | Italy | Generation | 0.232 kgCO₂e/kWh | 2025 |
| Electricity, heat pump, mono, air, DE, 2010, mix | ProBas | Germany | Useful heat, full life cycle | 0.188 kgCO₂e/kWh | 2010 |
| Deep geothermal energy - Final energy consumption, heat & cooling | UBA (DE) | Germany | Well-to-use | 0.0322 kgCO₂e/kWh | 2024 |