Emission factor from ProBas v02.44.152
Waste CHP plant, steam turbine, DE, 2005, heat, credit on the electricity mix
Germany · Useful heat, full life cycle · Any year
Value per kWh, net calorific value
−0.071kgCO₂e/kWh
Net calorific value · Biogenic CO₂ and land use excluded · GWP100 · AR6
FossilBio CH₄Land useBio CO₂GHG Protocol and IPCC inventoriesOne value, for any year
ProBas sets no date window, so there is no year to pick.
Reference year 2005
- Region
- Germany DE
- Boundary
- Useful heat, full life cycle
- Data quality
- MediumRated by us, not by the source
- Licence
- Open · ProBas terms
Where −0.071 comes from
ProBas prints this factor as a single figure, with no parts to add up.
Reporting this kilowatt-hour under the GHG Protocol
Scope 1 + Scope 2 + Scope 3, categories 2 and 3 −0.071
This one figure covers all four together; no split between them is given.
You burn the fuel, so its combustion is your Scope 1.
The plant and equipment behind your fuel are capital goods: Scope 3, category 2.
Supplying the fuel is Scope 3, category 3 for whoever burns it.
The factor, standardised
Every factor on open-climate.ai answers the same questions in the same words, whatever the publisher. Open any ⓘ for the definition.
Fuels › Waste-derived fuels · Germany · per kWh · Average
Useful heat, full life cycle · Excl. biogenic CO₂ · AR6
- BoundaryUseful heat, full life cycleFull life-cycle emissions of one kWh of useful heat delivered by a heating system: extraction and delivery of the fuel or electricity the system takes in, its combustion or conversion in the boiler, stove or heat pump, and the manufacture of the heating system itself amortized over its lifetime heat output. Learn more
- Useful heat, full life cycle
- Fuel supply, fuel combustion and capital goods
- GWP methodWhich IPCC assessment report's warming potentials convert each gas to CO₂e, and over how many years the warming is counted (GWP100: 100 years). Learn more
- IPCC AR6, 100-year horizon
- Re-weighted by open-climate.ai from ProBas's AR5 figure of −0.0711 kgCO₂e/kWh
- CO₂e basisWhich carbon the CO₂e counts. Fossil only leaves out biogenic methane, land-use change and biogenic CO₂; excl. biogenic CO₂ counts biogenic methane but not the other two; net total counts every pool, net of removals. The same activity on two bases is two different numbers. Learn more
- Excl. biogenic CO₂FossilBio CH₄Land useBio CO₂GHG Protocol and IPCC inventories
- Split by gas
Medium quality · Open licence · Any year
What this number covers
The path of one kilowatt-hour of this fuel, from the waste it is made from to the boiler. ProBas also counts its share of the plant and equipment.
Fuel supply
Collection
Collecting the waste it is made from
Preparation
Sorting, shredding and drying it
Transport
Moving it to your site
Your meter
1 kWh used. The factor is per kWh measured here.
Burning it
In the boiler or kiln: CO₂ from the fossil and biogenic carbon in the waste, with a little CH₄ and N₂O
= −0.071 per kWh
Gases
Basis: Excl. biogenic CO₂Biogenic CO₂ and land-use change are left out; fossil CO₂, the other greenhouse gases and methane from biogenic sources are counted. Learn moreFossilBio CH₄Land useBio CO₂GHG Protocol and IPCC inventories
- Fossil CO₂−0.066493.6%
- Methane (CH₄)−0.007710.9%
- Nitrous oxide (N₂O)0.00317−4.5%
Σ −0.0664 + −0.0077 + 0.00317 = -0.0709555, which ProBas rounds to −0.071.
Also printed, as zero: sulphur hexafluoride (SF₆).
Each gas is converted to CO₂e with AR6 100-year warming potentials; biogenic CO₂ and land-use carbon are left out, while methane from biogenic sources is counted.
From ProBas's record to a comparable factor
ProBas publishes this factor as one record. Here is each field as printed and what open-climate.ai made of it.
About this factor
From ProBas
Translated from GermanWaste incineration plant as combined heat and power plant, incl. flue-gas scrubbing + DeNOx, energy and emission data per #2 for typical German plants, all other values per #1. CO₂-Reduktion represents biogenic waste fractions !
Load factor: 7000h/a
Fuel/input: Fuels-Other
Land use: 101500m²
Firm capacity: 100%
Year: 2005
Lifetime: 15a
Capacity: 290MW
Efficiency: 27.2%
Product: Heat, Space heating
Allocation used: Allocation by creditsShow ProBas's original (German)
Müllverbrennungsanlage als Heizkraftwerk, inkl. Abgaswäsche + DeNOx, Energie- und Emissionsdaten nach #2 für bundestypische Anlagen, alle anderen Werte nach #1. CO2-Reduktion repräsentiert biogene Müllanteile !
Auslastung: 7000h/a
Brenn-/Einsatzstoff: Brennstoffe-Sonstige
Flächeninanspruchnahme: 101500m²
gesicherte Leistung: 100%
Jahr: 2005
Lebensdauer: 15a
Leistung: 290MW
Nutzungsgrad: 27,2%
Produkt: Wärme - Heizen
Verwendete Allokation: Allokation durch GutschriftenSource and licence
- Publisher
- Umweltbundesamt (German Environment Agency), ProBas
- Library
- ProBas v02.44.152
- Record
- a9af19b1-763c-42d0-b743-202694fb7ddc
- Published
- 16 September 2020
The values and their metadata are served in full and may be reused with credit to the publisher.
Es gelten die Probas Nutzungsbedingungen, die hier eingesehen werden können: https://probas.umweltbundesamt.de/daten/static/Nutzungsbedingungen_ProBas.pdf
Cite this factor
ProBas, Umweltbundesamt. Normalised by open-climate.ai, https://open-climate.ai/factors/libraries/probas/ (CC BY 4.0). https://open-climate.ai/factors/ef-probas-mullhkwdtde2005thelmix-de-kwh-useful_heat_lifecycle-9db92a37/?v=efv1-b264558950c021b7927c713a9ee5e155
Something looks wrong?
Tell us which value and why. We check it against the source and answer within a week.