Emission factor from SEMARNAT

Electric power generation, transmission and distribution - Dry gas for import

Mexico · Well-to-use · Any year

Each kilowatt-hour of this fuel counts as 0.236 kg CO₂e: 0.202 from burning it and 0.0335 for producing it and bringing it to you (estimated).

Value per kWh, net calorific value

0.236kgCO₂e/kWh

Net calorific value · Biogenic CO₂ and land use excluded · GWP100 · AR5

FossilBio CH₄Land useBio CO₂GHG Protocol and IPCC inventories

One value, for any year

SEMARNAT sets no date window, so there is no year to pick.

Reference year 2025

Estimated Summed by open-climate.ai from 2 parts, 1 of them estimated by us

Region
Mexico MX
Boundary
Well-to-use
Data quality
Very lowEstimated from another country's supply chain
Licence
Open · SEMARNAT terms

Where 0.236 comes from

  • Scope 10.20285.8%
  • Fuel supplyEstimatedDerived by open-climate.ai
    Scope 3, cat. 30.033514.2%
Derived by open-climate.ai

Σ 0.236: open-climate.ai adds up the two parts. SEMARNAT prints fuel combustion. open-climate.ai estimates fuel supply from other published figures.

Reporting this kilowatt-hour under the GHG Protocol

Scope 1 0.202 Scope 3, category 3 0.0335

You burn the fuel, so its combustion is your Scope 1.

Supplying the fuel is Scope 3, category 3 for whoever burns it.

CiteAPI

The factor, standardised

Every factor on open-climate.ai answers the same questions in the same words, whatever the publisher. Open any ⓘ for the definition.

Fuels › Gaseous fossil fuels · Mexico · per kWh · Generic

Well-to-use · Excl. biogenic CO₂ · AR5

Boundary
Well-to-use
Fuel supply and fuel combustion
GWP method
IPCC AR5, 100-year horizon
Not on the record; set from SEMARNAT's method notes
CO₂e basis
Excl. biogenic CO₂FossilBio CH₄Land useBio CO₂GHG Protocol and IPCC inventories
Not split by gas; CO₂e only

Very low quality · Open licence · Any year

Burning it, and getting it to you

Combustion is almost all CO₂. Methane and nitrous oxide are there too, too small to see at this scale, so they are drawn again below, 1000 times larger.

Inside combustion: the other two gases, drawn 1,000 times larger
  • CH₄0.000101
  • N₂O0.0000954

What this number covers

The path of one kilowatt-hour of this fuel, from the well to your flame. SEMARNAT gives one figure for the first three steps together.

  1. Well-to-tank0.0335Scope 3, cat. 3

    1. Extraction

      Getting the fuel out of the ground

    2. Processing

      Treating it to the quality it is sold at

    3. Transport

      Moving it to your site

  2. Your meter

    1 kWh used. The factor is per kWh measured here.

  3. Burning it

    In your boiler, furnace or engine: CO₂, with a little CH₄ and N₂O

    Scope 10.202

0.0335 + 0.202 = 0.236 per kWh

Outside this boundary

  • Making the boiler that burns it
  • Building the pipelines and the network

SEMARNAT counts the fuel, not the things built to extract, move and burn it.

Gases in the combustion part

0.202

Basis: Excl. biogenic CO₂FossilBio CH₄Land useBio CO₂GHG Protocol and IPCC inventories

  • Fossil CO₂0.20299.9%
  • Methane (CH₄)0.000101
  • Nitrous oxide (N₂O)0.0000954

Σ 0.202 + 0.000101 + 0.0000954 = 0.202.

Each gas is converted to CO₂e with AR5 100-year warming potentials; biogenic CO₂ and land-use carbon are left out, while methane from biogenic sources is counted.

The well-to-tank part is published as CO₂e only.

From SEMARNAT's record to a comparable factor

SEMARNAT publishes one of the two parts; open-climate.ai estimated the others and added them all up to this total. Here is each field as printed and what open-climate.ai made of it.

The total and its parts

Each part has its own page. Use a part on its own when you report Scope 1 and Scope 3 separately; never add a part to the total.

You are here · the totalElectric power generation, transmission and distribution, dry gas for import, well-to-use0.236

About this factor

Source and licence

Value
Summed by open-climate.ai from its parts
Publisher
SEMARNAT (Mexico)
Published
31 March 2025
See the source data at SEMARNAT

The values and their metadata are served in full and may be reused with credit to the publisher.

Credit it with this lineCalculadora de emisiones para el Registro Nacional de Emisiones (RENE), versión 9 (2025). SEMARNAT, Gobierno de México. Hoja 'Ecuaciones y FE'.
A plain reading of the licence, not legal advice. The licence text prevails.

Cite this factor

Calculadora de emisiones para el Registro Nacional de Emisiones (RENE), versión 9 (2025). SEMARNAT, Gobierno de México. Hoja 'Ecuaciones y FE'. Normalised by open-climate.ai, https://open-climate.ai/factors/libraries/semarnat/ (CC BY 4.0). https://open-climate.ai/factors/ef-semarnat-generacion_transmision_y-mx-kwh-well_to_use-bde5e5fd/?v=efv1-898c02f25de2a3208e4555a9e1e06e1f

Something looks wrong?

Tell us which value and why. We check it against the source and answer within a week.