One category axis
318 of 318 factor values mapped to one category
Mexico's official emission factors for reporting to the national emissions register: the yearly national grid electricity factor (FESEN) and the default factors of the register's emissions calculator.
One per year and method
1 region, sub-national included
The Factor de Emisión del Sistema Eléctrico Nacional (FESEN) is the grid factor companies use when they report to Mexico's Registro Nacional de Emisiones (RENE). It is not a database: each year's factor is a one-page regulatory notice (aviso), issued over time by the energy regulator CRE or by SEMARNAT, Mexico's environment ministry, and listed on gob.mx.
The set is one factor for the national grid, with one value per year for 2014 and 2017 to 2024. The latest year, 2024, is the value served by default.
SEMARNAT also publishes the emissions calculator for the RENE (Calculadora de emisiones para el RENE), an Excel workbook whose sheet of equations and factors gives a default factor for each fuel, fugitive source and industrial process an establishment declares. Here it is a second release stream of this library, version 9, dated 2025-03-31. Apart from the grid factor, its factor tables are the same as in the 2017 edition.
Standardised file
The publisher's file, re-cut into the schema every library on open-climate.ai shares: one category axis, coded regions, canonical units, AR6 warming potentials, the source row kept beside each value. What is in the file
318 of 318 factor values mapped to one category
1 region as an ISO or registry code
317 take the publisher's default region, stated rather than assumed
8 canonical units in 5 unit families, raw unit kept
141 factor values convert to a related unit
87 factor values recalculated on AR6
0 factor values already on AR6
177 factor values left on the publisher's GWP
54 factor values the same on every GWP
8 boundary codes
84 factor values state in, out or varies for each scope term
112 factor values grouped under 206 parents
Use a part on its own, or the parent when you want the whole.
56 estimated supply-chain legs (well-to-tank) the publisher does not print
56 totals over burning and supply
1 electricity factor states its instrument; one default, market first
318 of 318 factor values rated on one quality tier
English: 100.0% of factor values
German: 100.0% of factor values
Spanish: 100.0% of factor values
French: 100.0% of factor values
Italian: 3.8% of factor values
676 source rows archived
462 rows skipped, each with a reason
Slugs never break
73 old addresses redirect
Checks we run on every load to keep the data above trustworthy. Counts are for this library; the grey figure is the same check across all libraries. Point at the i to see why a check matters.
What the statuses meanHow checks are countedWhy we checkHow checks are grouped
Every source category maps to our vocabulary
Enforced when loaded
The publisher's classification is kept
Passed
Every classification level has a valid parent
Passed
Every product code comes with the codes above it
Passed
A publisher's own classification is used only by that publisher
Passed
A standard classification code has one label in every library
Passed
Every region is a known code
Enforced when loaded
No named region is filed under a broader one
Passed
Every region sits in the world hierarchy
Passed
Every unit is a known code
Enforced when loaded
One source unit maps to one unit
Passed
A unit label means the same in every library
Passed
A unit label that names no basis folds one way
Passed · 2 in all libraries
Every boundary states what it includes
Passed
Boundary scope terms are known codes
Passed
No two factors for the same activity partly overlap in scope
Passed
Separate stages of one activity are linked as parts, or documented as having no total
Passed
Every part of a factor states its boundary
Passed
Every biofuel counted with its biogenic CO2 says how much
Passed
No recycling credit is hidden inside a life-cycle total
Passed
No burden value hides a sizeable credit inside it
Passed · 13 in all libraries
Methane and nitrous oxide figures match the stated GWP
Passed
Every convertible value has its AR6 version
Passed
CO2e totals leave out what their basis excludes
Passed
Where a library breaks its totals down by gas, every total is broken down or reviewed
Passed · 693 in all libraries
Standardised figures keep every gas the publisher lists
Passed
Every value states what its CO2e total includes
Passed
A library with no AR6 version at all has a recorded reason
Passed
Every part links to a valid parent
Passed
No factor is an unlinked part of another factor
Passed
No part is larger than the total it belongs to
Passed
Every factor points to its top parent
Passed
No fuel estimate is served where the publisher printed the supply-chain figure
Passed
No supply-chain estimate is served for a fuel we deliberately left out
Passed
Every fuel estimate is built only from data we may redistribute
Passed
No fuel supply-chain estimate is rated above what its method allows
Passed
Every fuel eligible for a supply-chain estimate is classified
Passed
Every fuel supply-chain estimate still matches the figures it was computed from
Passed
The text of each fuel supply-chain estimate matches its current figures
Passed
Every electricity factor states its mix
Passed
The market-based value is the default
Passed
One default value per factor and year
Passed
Every green-electricity zero is a market-based value
Passed
Green-electricity zeros are not rated below market-based peers
Passed
Quality ratings fall inside their scale
Passed
Every zero value is explained
Passed
No default value is withheld without a stated reason
Passed
No implausibly high per-kilogram value is rated reliable
Passed
Every quality level gives a recognised reason
Passed
A zero that is only a gap in the source is withheld
Passed
The library is not rated entirely on one fallback quality level
Passed
Every factor has an English name
Passed
Translations match the current source text
Passed · 36 in all libraries
Translations follow a corrected source text
Passed · 1 in all libraries
Recorded translations survive a reload
Passed
Every served factor has a name
Passed
Each factor's name is its English name or the publisher's own, never a mix of both
Passed · 2 in all libraries
Every language with a main name also has a full name
Passed
Full names are built from their parts in the same language
Passed
Every text is labelled with its real language
Passed
Every description is available for display and translation
Passed
Every usage note is available for display and translation
Passed
Values traced to one source row agree with each other
Passed
No duplicate factors are served
Passed
No factor value claims two things that cannot both be true
Passed
No energy factor answers a question about packaging or recycling
Passed
Every served value past its publisher's end date has been reviewed
Passed · 9 in all libraries
One activity keeps one family across its units
Passed · 8 in all libraries
An activity's grouping key names only the activity
Passed · 2 in all libraries
A Creative Commons credit names its licence
Passed
No note of ours appears in the credit or licence notice
Passed
The credit line carries no terms of use
Passed
Every impact assessment method is a recognised code
Passed
Summed totals keep their parts' classification
Passed
Every summed total has a classification when its parts do
Passed
An avoided credit is linked to the burden it belongs to
Passed
Every value is typed as specific, generic or average
Passed
Summed totals equal their parts on every gas
Passed
No total is served when one of its parts is withheld
Passed
Validity dates are the publisher's own, never guessed
Passed
Every district-heat factor says whether the network's heat loss is included
Passed · 2 in all libraries
Quality breakdowns use their scheme's axes
Passed
No battery-electric vehicle carries tailpipe emissions
Passed
The text of each estimated electricity total matches its current figures
Passed
No EPD value is wildly off its peers without a review
Passed
Every estimated factor carries its description in each language
Passed
The text of each estimated factor matches its current figures
Passed
A total built on an estimated part is marked as estimated
Passed
Every estimated district-heat leg still adds up from its sources
Passed
Every estimate is built only from data we may redistribute
Passed
No estimated factor is rated above the data it was built from
Passed
No estimate sits beside a total of unclear scope
Passed
No estimate repeats a stage the publisher's total already includes
Passed
Every factor we complete has all of its estimated parts
Passed · 247 in all libraries
No estimate is served where the publisher printed the figure
Passed
We only estimate for publishers whose rule allows it
Passed
Every estimated factor still matches the inputs it was computed from
Passed
No estimated total competes with a published one
Passed
Every factor with a current value has a default
Passed
Every factor has a value, in a library that publishes values
Passed
Only food, farming and land factors carry a FLAG split
Passed
Every FLAG land-use change figure states its method and time frame
Passed
Every total equals the sum of its SBTi FLAG split
Passed
Every FLAG split says whether it was published or derived
Passed
Fossil-only CO2 is filed as fossil
Passed
Per-gas values are in CO2e
Passed
Every tagged gas has a known GWP
Passed
Every fixed group of regions lists what it covers
Passed
Where both exist, the residual mix is shown before the green-tariff zero
Passed
The newest edition of each value is the one marked current
Passed
Every publisher has a rule on whether we estimate its missing parts
Passed
Factor descriptions describe the factor, not the whole library
Passed
Every library's licence has its rights recorded
Passed
No fossil electricity mix has a zero fuel supply chain
Passed
Every green-electricity zero is exactly zero and says why
Passed
Green-electricity zeros cover power generation only
Passed
Only a total we computed may mix GWP vintages
Passed
Spend factors state their price year and basis
Passed
No electricity or heat factor answers network losses against its stage
Passed
Every value has a number, a GWP version and a reference year
Passed
Only a library cleared for it lists factors without their number
Passed
Plug-in hybrid factors say when the electricity is left out
Passed
A published total missing its fuel supply chain comes with a complete sum
Passed
Product footprints headline fossil carbon, like EPDs
Passed
No factor description is too long to display in full
Passed · 11 in all libraries
The library-wide answers on what a factor covers are up to date
Passed
Every library-wide answer applies to at least one factor
Passed
Every excused arithmetic disagreement still matches the published figures
Passed
Every reference year falls between 1960 and next year
Passed
Each library's current edition is the one its values come from
Passed
No two editions of a library share a release date
Passed
The parts of a total are never listed twice under one label
Passed
Every residual mix has its green-tariff counterpart
Passed
Every conservative value carries the same label
Passed
Every publisher's quality rating system is read
Passed
Every factor's boundary includes what its category measures
Passed
Every factor uses the most precise boundary for its category
Passed
Every factor is filed under the most specific category its source allows
Passed · 7,103 in all libraries
Every factor has a category
Passed
Every categorised factor has a GHG Protocol scope
Passed · 39 in all libraries
Single-gas values have their AR6 version
Passed · 10 in all libraries
No factor answers a question that does not arise for it
Passed · 9 in all libraries
A supplier named in the source is linked to the factor
Passed
A part covering the same scope as its total is linked to it
Passed
Every device total that includes its use also gives the manufacturing share (embodied emissions)
Passed · 115 in all libraries
Every estimated vehicle fuel-supply leg matches its sources
Passed
No plug-in vehicle supply-chain estimate is rated above what its method allows
Passed
Every exhaust-only vehicle factor gets a fuel-supply leg or a recorded reason
Passed
A year in a factor's name matches its reference year
Passed
Statute, checked on 17 Aug 2026
LFDA art. 14 fr. VIII: administrative texts are not subject to copyright; read with the gob.mx terms of use. No licence file exists.
Credit line
Calculadora de emisiones para el Registro Nacional de Emisiones (RENE), versión 9 (2025). SEMARNAT, Gobierno de México. Hoja 'Ecuaciones y FE'. Normalised by open-climate.ai, https://open-climate.ai/factors/libraries/semarnat/ (CC BY 4.0)
Not legal advice: the publisher's terms prevail.
Statute, checked on 17 Aug 2026
LFDA art. 14 fr. VIII: administrative texts are not subject to copyright; read with the gob.mx terms of use. No licence file exists.
Credit line
Factor de Emisión del Sistema Eléctrico Nacional. CRE/SEMARNAT, Registro Nacional de Emisiones (RENE), Gobierno de México. Avisos consultados en www.gob.mx/semarnat (consulta: 2026-08-17). Texto administrativo no sujeto a derecho de autor (LFDA art. 14, fr. VIII). Normalised by open-climate.ai, https://open-climate.ai/factors/libraries/semarnat/ (CC BY 4.0)
Not legal advice: the publisher's terms prevail.
What the library covers, by category and by boundary. Click a slice to drill in, then a sub-category or a boundary to filter the factors below.
Click a slice to see what is under it. A name opens its category page; its swatch hides it from the ring.
Click a slice to see what is under it. Click a name to hide it from the ring.
top 0 matches
| Saved | Unfold | Factor | Region | Boundary | Unit |
|---|---|---|---|---|---|
is_estimated) to keep them only. How the fuel legs are estimated.Mixed by stream: on the FESEN grid factor, the year the aviso's factor is for, never the date the aviso was issued (the 2014 factor was issued in October 2015); on the RENE calculator, 2025 on every value, the edition (v9) the calculator was published as, never a data year.
The FESEN is generation only. Beside it, open-climate.ai adds the fuel chain SEMARNAT never printed (extracting, refining and transporting the fuel the plants burn), as its own factor marked as an estimate, computed by a stated rule from the FESEN value and Ember's Mexican generation mix, and rated low quality. No loss leg is added: the only Mexican loss statistic, from the energy ministry SENER, is published under non-commercial terms, which our licence rule does not accept. So there is no fuel chain of the losses and no delivered total either. How the legs are estimated.
Open. The avisos carry no named licence. Mexican administrative texts are not subject to copyright (Ley Federal del Derecho de Autor, article 14, section VIII), and gob.mx publishes them as public information. Attribution: "Factor de Emisión del Sistema Eléctrico Nacional, CRE/SEMARNAT, Registro Nacional de Emisiones (RENE), Gobierno de México. Avisos consultados en www.gob.mx/semarnat (consulta: 2026-08-17). Texto administrativo no sujeto a derecho de autor (LFDA art. 14, fr. VIII)."
The same reading covers the RENE calculator, which SEMARNAT publishes on gob.mx with no licence text of its own. Attribution: "Calculadora de emisiones para el Registro Nacional de Emisiones (RENE), versión 9 (2025). SEMARNAT, Gobierno de México. Hoja 'Ecuaciones y FE'."
Credit line: Calculadora de emisiones para el Registro Nacional de Emisiones (RENE), versión 9 (2025). SEMARNAT, Gobierno de México. Hoja 'Ecuaciones y FE'.
A selection of SEMARNAT factors, with each value, boundary, source and derivation.
Direct emissionsIndustrial process emissions
Direct emissionsFugitive emissions and refrigerants
If SEMARNAT has published an edition we do not serve yet, tell us where to find it.