Emission factor from UBA (AT)
Liquefied petroleum gas LPG - Space heating
Austria · Well-to-use · Any year
Each kilowatt-hour of this fuel counts as 0.265 kg CO₂e: 0.231 from burning it and 0.034 for producing it and bringing it to you.
Value per kWh, net calorific value
0.265kgCO₂e/kWh
Net calorific value · Biogenic CO₂ and land use excluded · GWP100 · AR5
FossilBio CH₄Land useBio CO₂GHG Protocol and IPCC inventoriesOne value, for any year
UBA (AT) sets no date window, so there is no year to pick.
Reference year 2023
- Region
- Austria AT
- Boundary
- Well-to-use
- Data quality
- MediumRated by us, not by the source
- Licence
- Open · CC BY 4.0
Where 0.265 comes from
- Scope 10.23187.2%
- 3.3 Energy upstream0.03412.8%
Σ 0.265: the two parts add up to UBA (AT)'s published total.
Reporting this kilowatt-hour under the GHG Protocol
Scope 1 0.231 3.3 Energy upstream 0.034
You burn the fuel, so its combustion is your Scope 1.
Supplying the fuel is Scope 3, category 3 for whoever burns it.
The factor, standardised
Every factor on open-climate.ai answers the same questions in the same words, whatever the publisher. Open any ⓘ for the definition.
Fuels › Liquid fossil fuels · Austria · per kWh · Average
Well-to-use · Excl. biogenic CO₂ · AR5
- BoundaryWell-to-useOne unit of energy as consumed, priced from the well to the point of use: the well-to-tank chain plus the burn for a fuel; generation, its well-to-tank and the transmission and distribution losses for a delivered carrier (electricity, steam or hot water, chilled water). Learn more
- Well-to-use
- Fuel supply, fuel combustion, capital goods and infrastructure
- GWP methodWhich IPCC assessment report's warming potentials convert each gas to CO₂e, and over how many years the warming is counted (GWP100: 100 years). Learn more
- IPCC AR5, 100-year horizon
- Not on the record; inferred by open-climate.ai
- CO₂e basisWhich carbon the CO₂e counts. Fossil only leaves out biogenic methane, land-use change and biogenic CO₂; excl. biogenic CO₂ counts biogenic methane but not the other two; net total counts every pool, net of removals. The same activity on two bases is two different numbers. Learn more
- Excl. biogenic CO₂FossilBio CH₄Land useBio CO₂GHG Protocol and IPCC inventories
- Not split by gas; CO₂e only
Medium quality · Open licence · Any year
Burning it, and getting it to you
Two parts make up this factor: burning the fuel, and producing the fuel and bringing it to you.
- CombustionScope 10.231
- Well-to-tank3.3 Energy upstream0.034
| Part | Gas | kgCO₂e/kWh | Share | Scope |
|---|---|---|---|---|
| Combustion | CO₂e | 0.231 | 87.2% | Scope 1 |
| Well-to-tank | CO₂e | 0.034 | 12.8% | 3.3 Energy upstream |
| Total, well-to-use | CO₂e | 0.265 | 100% | Both |
What this number covers
The path of one kilowatt-hour of this fuel, from the well to your flame. UBA (AT) gives one figure for the first three steps together. UBA (AT) also counts its share of the plant and equipment.
Well-to-tank0.0343.3 Energy upstream
Extraction
Getting the fuel out of the ground
Processing
Treating it to the quality it is sold at
Transport
Moving it to your site
Your meter
1 kWh used. The factor is per kWh measured here.
Burning it
In your boiler, furnace or engine: CO₂, with a little CH₄ and N₂O
Scope 10.231
0.034 + 0.231 = 0.265 per kWh
Gases
UBA (AT) publishes this factor as CO₂e only, with no split by gas. The CO₂e leaves biogenic CO₂ and land-use carbon out; methane from biogenic sources is counted.
From UBA (AT)'s record to a comparable factor
UBA (AT) publishes this factor as one German record with two sub-lines. Here is each field as printed and what open-climate.ai made of it.
The total and its parts
Each part has its own page. Use a part on its own when you report Scope 1 and Scope 3 separately; never add a part to the total.
About this factor
From UBA (AT)
What it includes
The sum of these direct and upstream factors gives the total emission factors stated here.Show UBA (AT)'s original (German)
Die Summe aus diesen direkten und vorgelagerten Faktoren ergibt die hier angegebenen Gesamtemissionsfaktoren.Source and licence
- Publisher
- Umweltbundesamt GmbH (Austria)
- Published
- 16 October 2025
The values and their metadata are served in full and may be reused with credit to the publisher.
Cite this factor
Fritz David, Gössl Michael, Hatzl Eva, et al: Harmonisierte österreichische direkte und vorgelagerte THG-Emissionsfaktoren für relevante Energieträger & Technologien. Datenstand 2025. Wien, 2025. Reports, Band 0989. ISBN 978-3-99004-836-8. CC BY 4.0. Normalised by open-climate.ai, https://open-climate.ai/factors/libraries/uba_at/ (CC BY 4.0). https://open-climate.ai/factors/ef-ubaat-flussiggas_lpg_raumwarme-at-kwh-well_to_wheel-ca6d4d31/?v=efv1-99b0dbb2c3211fef050f04146caf3734
Something looks wrong?
Tell us which value and why. We check it against the source and answer within a week.
Page data as of .