Emission factor from UBA (AT)
Electricity supply, Austria - Electricity
Austria · Well-to-use · Any year
Each kilowatt-hour drawn from the grid counts as 0.152 kg CO₂e: 0.123 at the power plants and 0.029 for the fuel supplied to the power plants.
Value for any year
0.152kgCO₂e/kWh
Location-based · Consumption mix · Biogenic CO₂ and land use excluded · GWP100 · AR5
FossilBio CH₄Land useBio CO₂GHG Protocol and IPCC inventoriesOne value, for any year
UBA (AT) sets no date window, so there is no year to pick.
Reference year 2023
- Region
- Austria AT
- Boundary
- Well-to-use
- Data quality
- MediumRated by us, not by the source
- Licence
- Open · CC BY 4.0
Where 0.152 comes from
- Scope 20.12380.9%
- 3.3 Energy upstream0.02919.1%
Σ 0.152: the two parts add up to UBA (AT)'s published total.
Reporting this kilowatt-hour under the GHG Protocol
Scope 2 0.123 3.3 Energy upstream 0.029
You buy the energy, so its generation is your Scope 2.
Extracting, refining and delivering the fuel behind it happens upstream: Scope 3, category 3.
The factor, standardised
Every factor on open-climate.ai answers the same questions in the same words, whatever the publisher. Open any ⓘ for the definition.
Electricity › Grid electricity · Austria · per kWh · Average
Well-to-use · Location-based · Excl. biogenic CO₂ · AR5
- BoundaryWell-to-useOne unit of energy as consumed, priced from the well to the point of use: the well-to-tank chain plus the burn for a fuel; generation, its well-to-tank and the transmission and distribution losses for a delivered carrier (electricity, steam or hot water, chilled water). Learn more
- Well-to-use
- Fuel supply, generation, network losses and capital goods
- Calculation approachLocation-based uses the average grid mix where the electricity was consumed; market-based uses the supplier contract or the residual mix. The two can differ by an order of magnitude on the same kilowatt-hour, so they are never interchangeable. Learn more
- Location-based, consumption mix
- GWP methodWhich IPCC assessment report's warming potentials convert each gas to CO₂e, and over how many years the warming is counted (GWP100: 100 years). Learn more
- IPCC AR5, 100-year horizon
- Not on the record; inferred by open-climate.ai
- CO₂e basisWhich carbon the CO₂e counts. Fossil only leaves out biogenic methane, land-use change and biogenic CO₂; excl. biogenic CO₂ counts biogenic methane but not the other two; net total counts every pool, net of removals. The same activity on two bases is two different numbers. Learn more
- Excl. biogenic CO₂FossilBio CH₄Land useBio CO₂GHG Protocol and IPCC inventories
- Not split by gas; CO₂e only
- Life cycle
- Upstream: coveredProduction: coveredDownstream: not applicableEnd of life: not applicable
Medium quality · Open licence · Any year
What this number covers
The path of one kilowatt-hour, from the fuel to your meter. Every step on it is counted.
Fuel supply
Extracting, processing and transporting the fuel the plants burn
Included3.3 Energy upstream0.029Generation
Producing the electricity at the power plants that make up the mix
IncludedScope 20.123Your meter
1 kWh used. The factor is per kWh measured here.
= 0.152
Outside this boundary
- Building the grid
Capital goods and infrastructure sit outside every well-to-use factor, in every library.
Gases
UBA (AT) publishes this factor as CO₂e only, with no split by gas. The CO₂e leaves biogenic CO₂ and land-use carbon out; methane from biogenic sources is counted.
From UBA (AT)'s record to a comparable factor
UBA (AT) publishes this factor as one German record with two sub-lines. Here is each field as printed and what open-climate.ai made of it.
The total and its parts
Each part has its own page, with its own years and source record. Use a part on its own when you report Scope 2 and Scope 3 separately; never add a part to the total.
About this factor
From UBA (AT)
What it includes
The sum of these direct and upstream factors gives the total emission factors stated here.Show UBA (AT)'s original (German)
Die Summe aus diesen direkten und vorgelagerten Faktoren ergibt die hier angegebenen Gesamtemissionsfaktoren.Source and licence
- Publisher
- Umweltbundesamt GmbH (Austria)
- Published
- 16 October 2025
The values and their metadata are served in full and may be reused with credit to the publisher.
Cite this factor
Fritz David, Gössl Michael, Hatzl Eva, et al: Harmonisierte österreichische direkte und vorgelagerte THG-Emissionsfaktoren für relevante Energieträger & Technologien. Datenstand 2025. Wien, 2025. Reports, Band 0989. ISBN 978-3-99004-836-8. CC BY 4.0. Normalised by open-climate.ai, https://open-climate.ai/factors/libraries/uba_at/ (CC BY 4.0). https://open-climate.ai/factors/ef-ubaat-stromaufbringung-at-kwh-well_to_wheel-197b7f3a/?v=efv1-fca7358d8a22771fc69c4181f296d374
Something looks wrong?
Tell us which value and why. We check it against the source and answer within a week.
Page data as of .