Emission factor from IGES v11.7

Grid electricity generation, combined margin (CDM) - Government; OM 0.5 / BM 0.5 (projects other than wind and solar)

Colombia · Generation · 2023 onwards

Each kilowatt-hour generated this way from 2023 counts as 0.631 kg CO₂e at the power plants.

Value from 2023 onwards

0.631kgCO₂e/kWh

Location-based · Fossil only · CO₂ only

FossilBio CH₄Land useBio CO₂EN 15804 GWP-fossil
2023–
Default: the latest year+282.4% on 2022
Region
Colombia CO
Boundary
Generation
Data quality
MediumRated by us, not by the source
Licence
Open · IGES terms

Where 0.631 comes from

Published as one number

IGES prints this factor as a single figure, with no parts to add up.

Reporting this kilowatt-hour under the GHG Protocol

Scope 2 0.631

You buy the energy, so its generation is your Scope 2.

CiteAPI

The factor, standardised

Every factor on open-climate.ai answers the same questions in the same words, whatever the publisher. Open any ⓘ for the definition.

Electricity › Electricity by generation technology · Colombia · per kWh · Average

Generation · Location-based · Fossil only

Boundary
Generation
Calculation approach
Location-based
GWP method
None: the value counts CO₂ alone
CO₂ weighs 1 in every IPCC report, so no GWP applies
CO₂e basis
Fossil onlyFossilBio CH₄Land useBio CO₂EN 15804 GWP-fossil
All of it is CO₂
Life cycle
Upstream: not coveredProduction: coveredDownstream: not applicableEnd of life: not applicable

Medium quality · Open licence · 2012 to now

All values

12 values, one per year back to 2012. Every one is location-based, fossil only, so the years compare directly. Tap a bar.

2023 onwards0.631Default value

kgCO₂e per kWh, by year. Pick a year to read it.

What this number covers

The path of one kilowatt-hour, from the fuel to your meter. Not every step on it is counted; what is left out is listed below.

  1. Generation

    Producing the electricity at the power plants that make up the mix

    Included0.631
  2. Your meter

    1 kWh used. The factor is per kWh measured here.

    = 0.631

Outside this boundary

  • Electricity lost on the network
  • Producing and delivering the plants' fuel
  • Building the power plants

IGES counts burning fuel at the plants, not producing and delivering that fuel or building the plants.

Gases

Basis: Fossil onlyFossilBio CH₄Land useBio CO₂EN 15804 GWP-fossil

  • Fossil CO₂0.631

The CO₂e counts fossil carbon only; biogenic CO₂, biogenic methane and land-use carbon are left out.

From IGES's record to a comparable factor

IGES publishes this factor as one record. Here is each field as printed and what open-climate.ai made of it.

About this factor

From IGES

Where it applies

Official data includes only CMs. OM and BM are caluculated by the authors of this Database from CM values.

Source and licence

Publisher
Institute for Global Environmental Strategies (IGES)
Library
IGES v11.7
Published
6 March 2026
Open the record at IGES

The values and their metadata are served in full and may be reused with credit to the publisher.

All copyrights are reserved. The source must be clearly stated when this database is reproduced or transmitted in any form or by any means. Copyright: Ministry of the Environment, Japan.
Credit it with this lineInstitute for Global Environmental Strategies (2026). List of Grid Emission Factors, version 11.7. Available at: https://pub.iges.or.jp/pub/iges-list-grid-emission-factors
A plain reading of the licence, not legal advice. The licence text prevails.

Cite this factor

Institute for Global Environmental Strategies (2026). List of Grid Emission Factors, version 11.7. Available at: https://pub.iges.or.jp/pub/iges-list-grid-emission-factors. Normalised by open-climate.ai, https://open-climate.ai/factors/libraries/iges/ (CC BY 4.0). https://open-climate.ai/factors/ef-iges-grid_electricity-co-kwh-generation-7f4a0c9a/?v=efv1-629d1361f6f47ec79d9f743ce9eab5ca

Something looks wrong?

Tell us which value and why. We check it against the source and answer within a week.