Emission factor from ÖKOBAUDAT OBD_2024_III

Electricity grid mix

Germany · Well-to-use · 2023 onwards

Each kilowatt-hour drawn from the grid from 2023 counts as 0.478 kg CO₂e.

Value from 2023 onwards

0.478kgCO₂e/kWh

Location-based · Consumption mix · Fossil only · GWP100 · AR6

FossilBio CH₄Land useBio CO₂EN 15804 GWP-fossil
2023–
Default: the latest year+6.7% on 2022

Germany: every library's grid factor, side by side

Region
Germany DE
Boundary
Well-to-use
Data quality
MediumRated by us, not by the source
Licence
Open · ÖKOBAUDAT terms

Where 0.478 comes from

  • Fossil emissions
    Scope 2 3.3 Energy upstream0.478100%
  • Biogenic CO₂
    Outside0.00715beside

Σ 0.478: the fossil emissions are the total. ÖKOBAUDAT reports 0.00715 of biogenic CO₂ beside it, never in it.

Reporting this kilowatt-hour under the GHG Protocol

Scope 2 + 3.3 Energy upstream 0.478

This one figure covers both together; no split between them is given.

You buy the energy, so its generation is your Scope 2.

The fuel behind it and the energy lost on the way to you are Scope 3, category 3.

CiteAPI

The factor, standardised

Every factor on open-climate.ai answers the same questions in the same words, whatever the publisher. Open any ⓘ for the definition.

Electricity › Grid electricity · Germany · per kWh · Generic

Well-to-use · Location-based · Fossil only · AR6

Boundary
Well-to-use
Fuel supply, generation and network losses
Calculation approach
Location-based, consumption mix
GWP method
IPCC AR6, 100-year horizon
Not on the record; set from ÖKOBAUDAT's method notes · impact method EF 3.1
CO₂e basis
Fossil onlyFossilBio CH₄Land useBio CO₂EN 15804 GWP-fossil
Split by carbon origin, not by gas
Life cycle
Upstream: coveredProduction: coveredDownstream: not applicableEnd of life: not applicable

Medium quality · Open licence · 2017 to now

All values

7 values, one per year back to 2017. Every one is location-based, consumption mix, fossil only, AR6 GWP100, so the years compare directly. Tap a bar.

2023 onwards0.478Default value

kgCO₂e per kWh, by year. Pick a year to read it.

What this number covers

The path of one kilowatt-hour, from the fuel to your meter. Every step on it is counted.

  1. Fuel supply

    Extracting, processing and transporting the fuel the plants burn

    Included, not split out
  2. Generation

    Producing the electricity at the power plants that make up the mix

    Included, not split out
  3. Network losses

    Electricity lost between the plant and your meter, which still had to be generated

    Included, not split out
  4. Your meter

    1 kWh used. The factor is per kWh measured here.

    = 0.478

Outside this boundary

  • Building the power plants
  • Building the grid

Capital goods and infrastructure sit outside every well-to-use factor, in every library.

Gases

  • Fossil CO₂e0.478
  • Biogenic CO₂e0.00715
  • Land-use CO₂e0.0000906

The total counts fossil CO₂e. ÖKOBAUDAT reports biogenic and land-use CO₂e separately; they are shown beside it, not added.

From ÖKOBAUDAT's record to a comparable factor

ÖKOBAUDAT publishes this factor as one German record, and a new record every year. Here is each field as printed and what open-climate.ai made of it.

About this factor

From ÖKOBAUDAT

What it is

This data set has been modeled according to the European Standard EN 15804+A2 for Sustainable Building. Results are depicted in modules that allow the structured expression of results over the entire life cycle.

What it includes

Foreground system: The national or regional specific electricity consumption mix is provided by the conversion of the different energy carriers to electricity and imports from neighbouring countries, as illustrated in the pie chart "Electricity Mix". The electricity is either produced in energy carrier specific power plants and/or combined heat and power plants (CHP). Also considered are the national and regional specific technology standards of the power plants in regard to efficiency, firing technology, flue-gas desulphurisation, NOx removal and de-dusting. The electricity provided by non-combustible renewable energy sources also considers the national or regional situation, such as solar radiation (photovoltaic), annual full load hours (wind power), and share of hydro power stations by type (run-of-river, storage and pumped storage). The fossil power plant models combine emission data from literature with calculated values for non-measured emissions e.g. organics or heavy metals. For the emissions CO2, SO2, NOx, CO, CH4, N2O, NMVOC and particulate matter (PM) measured/calculated data are used, taken from national inventory reports, emission inventory data bases, utility companies and other sources. The calculation of other emissions within the models are based on energy carrier properties, transfer coefficients and power plant thermodynamics representing the applied flue gas treatment technologies and standards (flue gas desulphurisation, dust filter etc.). Combustion residues from solid fuels, such as gypsum, bottom ash or fly ash are assumed to be reused e.g. in construction work. Waste treatment for these substances is therefore not considered. Radioactive emissions from ashes are not considered in the coal power plant model. The energy carrier supply considers the whole supply chain of the energy carrier from exploration, production, processing and transport of the fuels to the power plants. The supply chain is modelled in specific national / regional energy carrier consumption mixes (i.e. domestic production and imports), and considers national / regional average energy carrier properties (e.g. elemental composition and energy content). The electricity grid mix includes imported electricity from neighbouring countries, transmission / distribution losses of low voltage electricity supply and the own use of electricity by energy producers (own consumption of power plants, and "other" own consumption e.g. due to pumped storage hydro power etc.). The logic of modelling the electricity consumption mix is represented in the flow diagram "Modelling of Electricity Consumption Mixes". Background system: Electricity: Electricity is modelled according to the individual country-specific situations. The country-specific modelling is achieved on multiple levels. Firstly, individual energy carrier specific power plants and plants for renewable energy sources are modelled according to the current national electricity grid mix. Modelling the electricity consumption mix includes transmission / distribution losses and the own use by energy producers (own consumption of power plants and "other" own consumption e.g. due to pumped storage hydro power etc.), as well as imported electricity. Secondly, the national emission and efficiency standards of the power plants are modelled as well as the share of electricity plants and combined heat and power plants (CHP). Thirdly, the country-specific energy carrier supply (share of imports and / or domestic supply) including the country-specific energy carrier properties (e.g. element and energy content) are accounted for. Fourthly, the exploration, mining/production, processing and transport processes of the energy carrier supply chains are modelled according to the specific situation of each electricity producing country. The different production and processing techniques (emissions and efficiencies) in the different energy producing countries are considered, e.g. different crude oil production technologies or different flaring rates at the oil platforms. Thermal energy, process steam: The thermal energy and process steam supply is modelled according to the individual country-specific situation with regard to emission standards and considered energy carriers. The thermal energy and process steam are produced at heat plants. Efficiencies for thermal energy production are by definition 100% in relation to the corresponding energy carrier input. For process steam the efficiency ranges from 85%, 90% to 95%. The energy carriers used for the generation of thermal energy and process steam are modelled according to the specific import situation (see electricity above). Transports: All relevant and known transport processes are included. Ocean-going and inland ship transport as well as rail, truck and pipeline transport of bulk commodities are considered. Energy carriers: The energy carriers are modelled according to the specific supply situation (see electricity above). Refinery products: Diesel fuel, gasoline, technical gases, fuel oils, lubricants and residues such as bitumen are modelled with a parameterised country-specific refinery model. The refinery model represents the current national standard in refining techniques (e.g. emission level, internal energy consumption, etc.) as well as the individual country-specific product output spectrum, which can be quite different from country to country. The supply of crude oil is modelled, again, according to the country-specific situation with the respective properties of the resources.

Where it applies

This product can be used in construction.

Source and licence

Publisher
ÖKOBAUDAT (BBSR / BMWSB)
Record
6edc9cb3-c65a-4b12-8eea-89064c9777d8 · process UUID
Published
13 November 2026
Valid until
31 December 2026
Status
Generic dataset
Open the record at ÖKOBAUDAT

The values and their metadata are served in full and may be reused with credit to the publisher.

Credit it with this lineSource: ÖKOBAUDAT (OBD_2024_III), BBSR / BMWSB. Individual EPDs © their respective programme operators / declaration owners.
A plain reading of the licence, not legal advice. The licence text prevails.

Cite this factor

Source: ÖKOBAUDAT (OBD_2024_III), BBSR / BMWSB. Individual EPDs © their respective programme operators / declaration owners. Normalised by open-climate.ai, https://open-climate.ai/factors/libraries/okobaudat/ (CC BY 4.0). https://open-climate.ai/factors/ef-okobaudat-electricity_grid_mix-de-kwh-b6-9ca93283/?v=efv1-73e6a3d95f6f13c334eec1292d213d74

Something looks wrong?

Tell us which value and why. We check it against the source and answer within a week.

Page data as of .