Usage - ventilation (1kWh electricity consumption)
ElectricityGrid-mix electricityWell-to-use (upstream, burn or generation, network losses)UP··Generic
0.473674kgCO₂e/kWhGWP: AR5 (as published)
Published by ÖKOBAUDAT (BBSR / BMWSB) in ÖKOBAUDAT (BBSR / BMWSB) OBD_2024_II (Any year); last verified 2026-08-28.
About this factor
Publisher's description
This data set has been modeled according to the European Standard EN 15804+A2 for Sustainable Building. Results are depicted in modules that allow the structured expression of results over the entire life cycle.
Included processesmachine-translated
For ventilation systems, very different usage datasets result from part-load operation, season and operating time, which additionally depend on the respective configuration of the systems. The electricity demand for ventilation can be calculated from the operating times, the average system air change rate n for mechanical ventilation and the net room volume of the building. The average system air change rate is given as 0.4 in DIN 18599 (part 10) (40% of the air is exchanged every hour). For the scaling of the dataset see the usage note and the attached table on the electrical power consumption of ventilation systems. Background system: Electricity: Electricity is modelled according to the individual country-specific situations. The country-specific modelling is achieved on multiple levels. 1.: Individual energy carrier specific power plants and plants for renewable energy sources are modelled according to the current national electricity grid mix. Modelling the electricity consumption mix includes transmission / distribution losses and the own use by energy producers (own consumption of power plants and "other" own consumption e.g. due to pumped storage hydro power etc.), as well as imported electricity. 2.: The national emission and efficiency standards of the power plants are modelled as well as the share of electricity plants and combined heat and power plants (CHP). 3.: The country-specific energy carrier supply (share of imports and / or domestic supply) including the country-specific energy carrier properties (e.g. element and energy content) are accounted for. 4.: The exploration, mining/production, processing and transport processes of the energy carrier supply chains are modelled according to the specific situation of each electricity producing country. The different production and processing techniques (emissions and efficiencies) in the different energy producing countries are considered, e.g. different crude oil production technologies or different flaring rates at the oil platforms. Thermal energy, process steam: The thermal energy and process steam supply is modelled according to the individual country-specific situation with regard to emission standards and considered energy carriers. The thermal energy and process steam are produced at heat plants. Efficiencies for thermal energy production are by definition 100% in relation to the corresponding energy carrier input. For process steam the efficiency ranges from 85-95%. The energy carriers used for the generation of thermal energy and process steam are modelled according to the specific import situation (see electricity above). Transports: All relevant and known transport processes are included. Ocean-going and inland ship transport as well as rail, truck and pipeline transport of bulk commodities are considered. Energy carriers: The energy carriers are modelled according to the specific supply situation (see electricity above). Refinery products: Diesel fuel, gasoline, technical gases, fuel oils, lubricants and residues such as bitumen are modelled with a parameterised country-specific refinery model. The refinery model represents the current national standard in refining techniques (e.g. emission level, internal energy consumption, etc.) as well as the individual country-specific product output spectrum, which can be quite different from country to country. The supply of crude oil is modelled, again, according to the country-specific situation with the respective properties of the resources.
Applicability
This product can be used in construction.
Values by year and methodology
| Any year |
|---|
By gas
| co2_fossil | 0.473674 | 98.8% |
| co2_biogenic | 0.005644 | 1.2% |
| co2_luluc | 0.000091 | 0.0% |
Cite this factor
open-climate.ai (n.d.). Usage - ventilation (1kWh electricity consumption) [emission factor]. ÖKOBAUDAT (BBSR / BMWSB), ÖKOBAUDAT (BBSR / BMWSB) OBD_2024_II. Dataset 2026-08-28. Retrieved 2026-09-25. https://open-climate.ai/factors/ef-okobaudat-usage_ventilation_1kwh-de-kwh-b6-dcff9335