Emission factor from ProBas v02.44.152

Pipeline: crude oil, TH, 2015

Thailand · Cradle to gate · Any year

Each kilowatt-hour of this fuel counts as 0.0215 kg CO₂e up to the factory gate. ProBas gives one figure, for use in any year.

Value per kWh, net calorific value

0.0215kgCO₂e/kWh

Net calorific value · Biogenic CO₂ and land use excluded · GWP100 · AR6

FossilBio CH₄Land useBio CO₂GHG Protocol and IPCC inventories

One value, for any year

ProBas sets no date window, so there is no year to pick.

Reference year 2015

Region
Thailand TH
Boundary
Cradle to gate
Data quality
MediumRated by us, not by the source
Licence
Open · ProBas terms

Where 0.0215 comes from

Published as one number

ProBas prints this factor as a single figure, with no parts to add up.

Reporting this kilowatt-hour under the GHG Protocol

Scope 3, category 3 0.0215

Supplying the fuel is Scope 3, category 3 for whoever burns it.

CiteAPI

The factor, standardised

Every factor on open-climate.ai answers the same questions in the same words, whatever the publisher. Open any ⓘ for the definition.

Fuels › Liquid fossil fuels · Thailand · per kWh · Average

Cradle to gate · Excl. biogenic CO₂ · AR6

Boundary
Cradle to gate
Fuel supply, fuel combustion and capital goods
GWP method
IPCC AR6, 100-year horizon
Re-weighted by open-climate.ai from ProBas's AR5 figure of 0.0215 kgCO₂e/kWh
CO₂e basis
Excl. biogenic CO₂FossilBio CH₄Land useBio CO₂GHG Protocol and IPCC inventories
Split by gas
Life cycle
Upstream: coveredProduction: coveredDownstream: not coveredEnd of life: not covered

Medium quality · Open licence · Any year

What this number covers

The path of one kilowatt-hour of this fuel, from the well to your flame. ProBas also counts its share of the plant and equipment.

  1. Well-to-tank

    1. Extraction

      Getting the fuel out of the ground

    2. Processing

      Treating it to the quality it is sold at

    3. Transport

      Moving it to your site

  2. Your meter

    1 kWh used. The factor is per kWh measured here.

  3. Burning it

    In your boiler, furnace or engine: CO₂, with a little CH₄ and N₂O

= 0.0215 per kWh

Gases

Basis: Excl. biogenic CO₂FossilBio CH₄Land useBio CO₂GHG Protocol and IPCC inventories

  • Fossil CO₂0.019791.8%
  • Methane (CH₄)0.001677.8%
  • Nitrous oxide (N₂O)0.00008160.4%

Σ 0.0197 + 0.00167 + 0.0000816 = 0.0215.

Also printed, as zero: sulphur hexafluoride (SF₆).

Each gas is converted to CO₂e with AR6 100-year warming potentials; biogenic CO₂ and land-use carbon are left out, while methane from biogenic sources is counted.

From ProBas's record to a comparable factor

ProBas publishes this factor as one record. Here is each field as printed and what open-climate.ai made of it.

About this factor

From ProBas

Translated from German
Pipeline for crude oil transport, data for the electricity demand from #1, for material inputs from #2, distance from #3. Load factor: 7500h/a Fuel/input: Fuels-fossil-oil Year: 2015 Length: 500km Lifetime: 15a Capacity: 37000MW Product: Fuels-fossil-oil
Show ProBas's original (German)
Pipeline für Rohöl-Transport, Daten für den Strombedarf nach #1, für Materialaufwendungen nach #2, Distanz nach #3. Auslastung: 7500h/a Brenn-/Einsatzstoff: Brennstoffe-fossil-Öl Jahr: 2015 Länge: 500km Lebensdauer: 15a Leistung: 37000MW Produkt: Brennstoffe-fossil-Öl

Source and licence

Publisher
Umweltbundesamt (German Environment Agency), ProBas
Record
70edb4e8-e82f-4d67-b904-46dae83b5c6f
Published
16 September 2020
Open the record at ProBas

The values and their metadata are served in full and may be reused with credit to the publisher.

Es gelten die Probas Nutzungsbedingungen, die hier eingesehen werden können: https://probas.umweltbundesamt.de/daten/static/Nutzungsbedingungen_ProBas.pdf
Credit it with this lineProBas, Umweltbundesamt
A plain reading of the licence, not legal advice. The licence text prevails.

Cite this factor

ProBas, Umweltbundesamt. Normalised by open-climate.ai, https://open-climate.ai/factors/libraries/probas/ (CC BY 4.0). https://open-climate.ai/factors/ef-probas-pipelineolrohth2015-th-kwh-cradle_to_gate-c2346608/?v=efv1-2cf93eae8050dfb10f16c174ed75066a

Something looks wrong?

Tell us which value and why. We check it against the source and answer within a week.