One category axis
6 of 6 factor values mapped to one category
The carbon intensity of the electricity generated in the Emirate of Dubai, one value a year from 2016 to 2025, printed by the Dubai Electricity and Water Authority in its annual Sustainability Report.
One per year and method
The Dubai Electricity and Water Authority (DEWA) is the Emirate of Dubai's electricity and water utility, majority owned by the Government of Dubai. It publishes no emission factor dataset. Each Sustainability Report prints, in a chart and a sentence, the carbon intensity of the electricity its Dubai plants generated, in tonnes of CO2e per MWh.
We load one series from six English editions, 2020 to 2025: ten values, 2016 to 2025. Each year is read from the latest edition that prints it. The latest year, 2025, is the value served by default.
6 of 6 factor values mapped to one category
1 region as an ISO or registry code
6 take the publisher's default region, stated rather than assumed
1 canonical unit in 1 unit families, raw unit kept
None is converted: every value keeps the publisher's GWP.
6 factor values left on the publisher's GWP
5 boundary codes
4 factor values state in, out or varies for each scope term
5 factor values grouped under 1 parents
Use a part on its own, or the parent when you want the whole.
3 estimated legs the publisher does not print (grid losses, the fuel chain)
2 totals that include an estimated leg
6 electricity factors state their instrument; one default, market first
6 of 6 factor values rated on one quality tier
English: 100.0% of factor values
German: 100.0% of factor values
French: 100.0% of factor values
10 source rows archived
Slugs never break
Checks we run on every load to keep the data above trustworthy. Counts are for this library; the grey figure is the same check across all libraries. Point at the i to see why a check matters.
What the statuses meanHow checks are countedWhy we checkHow checks are grouped
Values that exclude a carbon pool list the gases behind the total
Known limitation · 40 in this library · 180,272 in all libraries
Every source category maps to our vocabulary
Enforced when loaded
The publisher's classification is kept
Passed
Every classification level has a valid parent
Passed
Every product code comes with the codes above it
Passed
A publisher's own classification is used only by that publisher
Passed
A standard classification code has one label in every library
Passed
Every region is a known code
Enforced when loaded
No named region is filed under a broader one
Passed
Every region sits in the world hierarchy
Passed
Every unit is a known code
Enforced when loaded
One source unit maps to one unit
Passed
A unit label means the same in every library
Passed
A unit label that names no basis folds one way
Passed · 2 in all libraries
Every boundary states what it includes
Passed
Boundary scope terms are known codes
Passed
No two factors for the same activity partly overlap in scope
Passed
Separate stages of one activity are linked as parts
Passed
Every part of a factor states its boundary
Passed
Every biofuel counted with its biogenic CO2 says how much
Passed
No recycling credit is hidden inside a life-cycle total
Passed
No burden value hides a credit inside it
Passed · 348 in all libraries
Methane and nitrous oxide figures match the stated GWP
Passed
Every convertible value has its AR6 version
Passed
CO2e totals leave out what their basis excludes
Passed
Values that exclude a carbon pool list the gases behind the total
Known limitation · 40 in this library · 180,272 in all libraries
Standardised figures keep every gas the publisher lists
Passed
Every value states what its CO2e total includes
Passed
A library with no AR6 version at all has a recorded reason
Passed
Every part links to a valid parent
Passed
No factor is an unlinked part of another factor
Passed
No part is larger than the total it belongs to
Passed
Every factor points to its top parent
Passed
No estimate is served where the publisher printed the figure
Passed
Every estimate is built only from data we may redistribute
Passed
No estimated factor is rated above the data it was built from
Passed
Every estimated factor still matches the inputs it was computed from
Passed
A total built on an estimated part is marked as estimated
Passed
Every estimated factor carries its description in each language
Passed
The text of each estimated factor matches its current figures
Passed
The text of each estimated electricity total matches its current figures
Passed
Every electricity factor states its mix
Passed
The market-based value is the default
Passed
One default value per factor and year
Passed
Every green-electricity zero is a market-based value
Passed
Green-electricity zeros are not rated below market-based peers
Passed
Quality ratings fall inside their scale
Passed
Every zero value is explained
Passed
No default value is withheld for poor quality
Passed
No implausibly high per-kilogram value is rated reliable
Passed
Every quality level gives a recognised reason
Passed
A zero that is only a gap in the source is withheld
Passed
The library is not rated entirely on one fallback quality level
Passed
Every factor has an English name
Passed
Translations match the current source text
Passed
Translations follow a corrected source text
Passed
Recorded translations survive a reload
Passed
Every served factor has a name
Passed
Factors are searched on their English name where one exists
Passed · 24 in all libraries
Every language with a main name also has a full name
Passed
Full names are built from their parts in the same language
Passed
Every text is labelled with its real language
Passed
Every description is available for display and translation
Passed
Every usage note is available for display and translation
Passed
Values traced to one source row agree with each other
Passed
No duplicate factors are served
Passed
No factor value claims two things that cannot both be true
Passed
No energy factor answers a question about packaging or recycling
Passed · 169 in all libraries
No factor value the publisher has withdrawn is still served
Passed · 14,762 in all libraries
One activity keeps one family across its units
Passed · 8 in all libraries
An activity's grouping key names only the activity
Passed · 12 in all libraries
A Creative Commons credit names its licence
Passed
No note of ours appears in the credit or licence notice
Passed
The credit line carries no terms of use
Passed
Every impact assessment method is a recognised code
Passed
Summed totals keep their parts' classification
Passed
Every summed total has a classification when its parts do
Passed
An avoided credit is linked to the burden it belongs to
Passed
Every value is typed as specific, generic or average
Passed
Summed totals equal their parts on every gas
Passed
No total is served when one of its parts is withheld
Passed
Validity dates are the publisher's own, never guessed
Passed
Every district-heat factor says whether the network's heat loss is included
Passed · 2 in all libraries
Quality breakdowns use their scheme's axes
Passed
No battery-electric vehicle carries tailpipe emissions
Passed
No estimate sits beside a total of unclear scope
Passed
No estimate repeats a stage the publisher's total already includes
Passed
Every factor we complete has all of its estimated parts
Passed · 25 in all libraries
We only estimate for publishers whose rule allows it
Passed
No estimated total competes with a published one
Passed
Every factor with a current value has a default
Passed
Every factor has a value, in a library that publishes values
Passed
The text of each fuel supply-chain estimate matches its current figures
Passed
No fuel supply-chain estimate is rated above what its method allows
Passed
Every fuel estimate is built only from data we may redistribute
Passed
Every fuel eligible for a supply-chain estimate is classified
Passed
No fuel estimate is served where the publisher printed the supply-chain figure
Passed
No supply-chain estimate is served for a fuel we deliberately left out
Passed
Every fuel supply-chain estimate still matches the figures it was computed from
Passed
Per-gas values are in CO2e
Passed
Every tagged gas has a known GWP
Passed
Every fixed group of regions lists what it covers
Passed
Where both exist, the residual mix is shown before the green-tariff zero
Passed
The newest edition of each value is the one marked current
Passed
Every publisher has a rule on whether we estimate its missing parts
Passed
Factor descriptions describe the factor, not the whole library
Passed · 2 in all libraries
Every library's licence has its rights recorded
Passed
No fossil electricity mix has a zero fuel supply chain
Passed
Every green-electricity zero is exactly zero and says why
Passed
Green-electricity zeros cover power generation only
Passed
Only a total we computed may mix GWP vintages
Passed
Spend factors state their price year and basis
Passed
No electricity or heat factor answers network losses against its stage
Passed · 4 in all libraries
Every value has a number, a GWP version and a reference year
Passed
Only a library cleared for it lists factors without their number
Passed
Product footprints headline fossil carbon, like EPDs
Passed
No factor description is too long to display in full
Passed · 5 in all libraries
The library-wide answers on what a factor covers are up to date
Passed
Every library-wide answer applies to at least one factor
Passed · 3 in all libraries
Every excused arithmetic disagreement is stated
Passed
Every reference year falls between 1960 and next year
Passed
Each library's current edition is the one its values come from
Passed
No two editions of a library share a release date
Passed
The parts of a total are never listed twice under one label
Passed
Every residual mix has its green-tariff counterpart
Passed
Every conservative value carries the same label
Passed
Every publisher's quality rating system is read
Passed
Every factor is filed under the most specific category its source allows
Passed · 4,552 in all libraries
Every factor has a category
Passed
Every categorised factor has a GHG Protocol scope
Passed · 2 in all libraries
Single-gas values have their AR6 version
Passed · 8 in all libraries
No factor answers a question that does not arise for it
Passed · 11 in all libraries
A supplier named in the source is linked to the factor
Passed
A part covering the same scope as its total is linked to it
Passed
Every device total that includes its use also gives the manufacturing share (embodied emissions)
Passed · 112 in all libraries
No plug-in vehicle supply-chain estimate is rated above what its method allows
Passed
A year in a factor's name matches its reference year
Passed
Our reading, where no written grant settles it, checked on 14 Oct 2026
DEWA states no licence, no copyright notice and no terms of use: six English Sustainability Reports (2020 to 2025), the 2025 Climate Policy, robots.txt and the site's 13,011 sitemap URLs were searched. The only rights clause in the corpus is DNV's, over its own verification statement. Tier restricted on owner decision X2 A (2026-10-12); a permission request to DEWA is the owner's to send (dewa, IMP-0065).
Credit line
Dubai Electricity and Water Authority (DEWA PJSC), Sustainability Report 2025 and earlier editions (2020-2024). Normalised by open-climate.ai, https://open-climate.ai/factors/libraries/dewa/ (CC BY 4.0)
Not legal advice: the publisher's terms prevail.
top 0 matches
| Saved | Unfold | Factor | Region | Boundary | Unit |
|---|---|---|---|---|---|
| Version | Published | Loaded | Status | Source |
|---|---|---|---|---|
| sustainability-report-2025 | – | 14 Oct 2026 | Served | Source |
Data year: the calendar year of generation the Dubai grid factor is for (2016-2025), never the year of the report that printed it.
DEWA's value is generation only. Beside it, open-climate.ai adds three factors DEWA never printed, each marked as an estimate: the fuel chain (extracting, processing and transporting the fuel the plants burn), computed from UK Government conversion factors weighted by Ember's fuel mix for the United Arab Emirates; the electricity lost in transmission and distribution, from the U.S. EIA loss share for the United Arab Emirates; and the fuel chain of that lost electricity. Two totals add them up: the losses with their fuel chain, and the delivered total. These estimates follow the UK factors' IPCC AR5 basis. Their inputs describe the whole country, not Dubai. How the legs are estimated.
Restricted. DEWA states no licence, no copyright notice and no terms of use anywhere: we searched the six English reports, the 2025 Climate Policy and the 13,011 pages of DEWA's website. The only rights statement in the reports is that of DNV, the verifier, over its own verification statement. Because nothing is granted, open-climate.ai classes the library as restricted: the public site lists the factor with its metadata and withholds the values.
Using the factor for your own footprint is allowed, and publishing results that name the source is allowed. Nothing is said about sharing the values with customers, embedding them in a product, or modifying and combining them: confirm with DEWA before you do. If DEWA grants terms, the tier changes without the factor changing. Attribution: "Dubai Electricity and Water Authority (DEWA PJSC), Sustainability Report 2025 and earlier editions (2020-2024)." Last verified 2026-10-14.
Credit line: Dubai Electricity and Water Authority (DEWA PJSC), Sustainability Report 2025 and earlier editions (2020-2024).
If DEWA has published an edition we do not serve yet, tell us where to find it.