Emission factor from AIB 2025

Grid electricity

Iceland · Transmission and distribution losses · 2025 onwards

Each kilowatt-hour you buy from 2025 without a green tariff or certificate behind it counts as 0.00000622 kg CO₂e for the electricity lost on the network (estimated). That is the 3.3 Energy upstream part of the total for Grid electricity.

Value from 2025 onwards

0.00000622kgCO₂e/kWh

Market-based · Residual mix · Fossil only · CO₂ only

FossilBio CH₄Land useBio CO₂EN 15804 GWP-fossil
2025–
Default: the latest year+19.3% on 2024

Estimated By open-climate.ai, not published by AIB

Region
Iceland IS
Boundary
Transmission and distribution losses
Data quality
LowEstimated from figures for the region
Licence
Open · AIB terms

Where 0.00000622 comes from

Estimated by open-climate.ai

AIB does not publish this value. open-climate.ai estimated it from AIB's published figures and a regional statistic.

The total: Grid electricity

How it was estimated

Reporting this kilowatt-hour under the GHG Protocol

3.3 Energy upstream 0.00000622

The energy lost on the way to you is Scope 3, category 3.

CiteAPI

The factor, standardised

Every factor on open-climate.ai answers the same questions in the same words, whatever the publisher. Open any ⓘ for the definition.

Electricity › Grid electricity · Iceland · per kWh · Average

Transmission and distribution losses · Market-based · Fossil only

Boundary
Transmission and distribution losses
Network losses
Calculation approach
Market-based, residual mix
GWP method
None: the value counts CO₂ alone
CO₂ weighs 1 in every IPCC report, so no GWP applies
CO₂e basis
Fossil onlyFossilBio CH₄Land useBio CO₂EN 15804 GWP-fossil
All of it is CO₂
Life cycle
Upstream: not coveredProduction: not coveredDownstream: not applicableEnd of life: not applicable

Low quality · Open licence · 2022 to now

All values

16 values: 4 methods over 4 periods back to 2022. Tap a bar.

2025 onwards · Market-based · residual mix0.00000622Default valueEstimated

kgCO₂e per kWh, by year, for market-based · residual mix. Pick a year to read it.

What this number covers

The path of one kilowatt-hour, from the fuel to your meter. This factor counts one step of it; the others have factors of their own.

  1. Fuel supply

    Extracting, processing and transporting the fuel the plants burn

    Not in this part
  2. Generation

    Producing the electricity at the power plants that make up the mix

    Not in this part
  3. Network losses

    Electricity lost between the plant and your meter, which still had to be generated

    Counted here0.00000622
  4. Your meter

    1 kWh used. The factor is per kWh measured here.

Outside this boundary

  • Building the power plants

Capital goods and infrastructure sit outside every well-to-use factor, in every library.

From AIB's inputs to a comparable factor

AIB publishes the inputs; open-climate.ai estimated this value from them, so no printed record stands beside it.

Checks this factor passed

  • Unit, region, boundary and method mapped to fixed code lists.
How we standardise every library

The total and its parts

Use a part on its own when you report its scope apart from the others. Never add a part to the total.

↑ The totalGrid electricity
You are here · 3.3 Energy upstreamT&D losses0.00000622

About this factor

Source and licence

Value
Estimated by open-climate.ai from this source
Publisher
Association of Issuing Bodies (AIB)
Library
AIB 2025
Published
28 May 2026
See the source data at AIB

The values and their metadata are served in full and may be reused with credit to the publisher.

Credit it with this lineSource: Association of Issuing Bodies (AIB), European Residual Mixes 2022-2025.
A plain reading of the licence, not legal advice. The licence text prevails.

Cite this factor

Source: Association of Issuing Bodies (AIB), European Residual Mixes 2022-2025. Normalised by open-climate.ai, https://open-climate.ai/factors/libraries/aib/ (CC BY 4.0). https://open-climate.ai/factors/ef-aib-grid_electricity-is-kwh-transmission_distributio-fce18a71/?v=efv1-9e78d0f44da2a257e84a25a2bd988aaa

Something looks wrong?

Tell us which value and why. We check it against the source and answer within a week.

Page data as of .